Fx Copy
LaTeX Copy
The Impedance of Primary Winding is the total of primary Resistance and Reactance. Check FAQs
Z1=ViIi
Z1 - Impedance of Primary Winding?Vi - Incident Voltage?Ii - Incident Current?

Impedance-1 using Incident Current and Voltage (Line PL) Example

With values
With units
Only example

Here is how the Impedance-1 using Incident Current and Voltage (Line PL) equation looks like with Values.

Here is how the Impedance-1 using Incident Current and Voltage (Line PL) equation looks like with Units.

Here is how the Impedance-1 using Incident Current and Voltage (Line PL) equation looks like.

0.5Edit=6Edit12Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Impedance-1 using Incident Current and Voltage (Line PL)

Impedance-1 using Incident Current and Voltage (Line PL) Solution

Follow our step by step solution on how to calculate Impedance-1 using Incident Current and Voltage (Line PL)?

FIRST Step Consider the formula
Z1=ViIi
Next Step Substitute values of Variables
Z1=6V12A
Next Step Prepare to Evaluate
Z1=612
LAST Step Evaluate
Z1=0.5Ω

Impedance-1 using Incident Current and Voltage (Line PL) Formula Elements

Variables
Impedance of Primary Winding
The Impedance of Primary Winding is the total of primary Resistance and Reactance.
Symbol: Z1
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Incident Voltage
The Incident Voltage on the transmission line is equal to half the generator voltage.
Symbol: Vi
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Incident Current
Incident Current is the Current wave that is traveling from the sending end to the receiving end of the Transmission line during any transient condition.
Symbol: Ii
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Impedance of Primary Winding

​Go Impedance-1 using Transmitted Voltage (Line PL)
Z1=(Vi-Er)Z2+Z3Vt
​Go Impedance-1 using Transmitted Coefficient of Current-2 (Line PL)
Z1=τiViZ2Vt
​Go Impedance-1 using Transmitted Coefficient of Current-3 (Line PL)
Z1=τiZ3τv
​Go Impedance-1 for Transmitted Coefficient of Current-3 (Line PL)
Z1=τiZ3τv

Other formulas in Impedance 1,2 and 3 category

​Go Impedance-2 using Transmitted Current-2 (Line PL)
Z2=VtIt
​Go Impedance-2 using Transmitted Voltage (Line PL)
Z2=VtIt
​Go Impedance-3 using Transmitted Voltage (Line PL)
Z3=VtIt
​Go Impedance-2 using Transmitted Coefficient of Voltage (Line PL)
Z2=(2Z1τv)-(1Z1)-(1Z3)

How to Evaluate Impedance-1 using Incident Current and Voltage (Line PL)?

Impedance-1 using Incident Current and Voltage (Line PL) evaluator uses Impedance of Primary Winding = Incident Voltage/Incident Current to evaluate the Impedance of Primary Winding, The Impedance-1 using Incident Current and Voltage (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance-1 is measured in ohms. Impedance of Primary Winding is denoted by Z1 symbol.

How to evaluate Impedance-1 using Incident Current and Voltage (Line PL) using this online evaluator? To use this online evaluator for Impedance-1 using Incident Current and Voltage (Line PL), enter Incident Voltage (Vi) & Incident Current (Ii) and hit the calculate button.

FAQs on Impedance-1 using Incident Current and Voltage (Line PL)

What is the formula to find Impedance-1 using Incident Current and Voltage (Line PL)?
The formula of Impedance-1 using Incident Current and Voltage (Line PL) is expressed as Impedance of Primary Winding = Incident Voltage/Incident Current. Here is an example- 0.5 = 6/12.
How to calculate Impedance-1 using Incident Current and Voltage (Line PL)?
With Incident Voltage (Vi) & Incident Current (Ii) we can find Impedance-1 using Incident Current and Voltage (Line PL) using the formula - Impedance of Primary Winding = Incident Voltage/Incident Current.
What are the other ways to Calculate Impedance of Primary Winding?
Here are the different ways to Calculate Impedance of Primary Winding-
  • Impedance of Primary Winding=(Incident Voltage-Reflected Voltage)*(Impedance of Secondary Winding+Impedance of Tertiary Winding)/Transmitted VoltageOpenImg
  • Impedance of Primary Winding=Transmission Coefficient of Current*Incident Voltage*Impedance of Secondary Winding/(Transmitted Voltage)OpenImg
  • Impedance of Primary Winding=Transmission Coefficient of Current*Impedance of Tertiary Winding/Transmission Coefficient of VoltageOpenImg
Can the Impedance-1 using Incident Current and Voltage (Line PL) be negative?
Yes, the Impedance-1 using Incident Current and Voltage (Line PL), measured in Electric Resistance can be negative.
Which unit is used to measure Impedance-1 using Incident Current and Voltage (Line PL)?
Impedance-1 using Incident Current and Voltage (Line PL) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Impedance-1 using Incident Current and Voltage (Line PL) can be measured.
Copied!