Hydraulic Retention Time in Seconds is referred as the ratio between the reactor volume and the feed flow rate, it represents the average time the cells and substrates stay inside the reactor. Check FAQs
θs=FMShXh
θs - Hydraulic Retention Time in Seconds?FM - F:M Ratio?Sh - Influent Substrate Concentration h?Xh - MLVSS Hydraulic Retention Time?

Hydraulic Retention Time given Food to Microorganism Ratio Example

With values
With units
Only example

Here is how the Hydraulic Retention Time given Food to Microorganism Ratio equation looks like with Values.

Here is how the Hydraulic Retention Time given Food to Microorganism Ratio equation looks like with Units.

Here is how the Hydraulic Retention Time given Food to Microorganism Ratio equation looks like.

7.1225Edit=0.2Edit50Edit0.0065Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Hydraulic Retention Time given Food to Microorganism Ratio

Hydraulic Retention Time given Food to Microorganism Ratio Solution

Follow our step by step solution on how to calculate Hydraulic Retention Time given Food to Microorganism Ratio?

FIRST Step Consider the formula
θs=FMShXh
Next Step Substitute values of Variables
θs=0.2d⁻¹50mg/L0.0065mg/L
Next Step Convert Units
θs=2.3E-6s⁻¹0.05kg/m³6.5E-6kg/m³
Next Step Prepare to Evaluate
θs=2.3E-60.056.5E-6
Next Step Evaluate
θs=7.12250712250711s
LAST Step Rounding Answer
θs=7.1225s

Hydraulic Retention Time given Food to Microorganism Ratio Formula Elements

Variables
Hydraulic Retention Time in Seconds
Hydraulic Retention Time in Seconds is referred as the ratio between the reactor volume and the feed flow rate, it represents the average time the cells and substrates stay inside the reactor.
Symbol: θs
Measurement: TimeUnit: s
Note: Value should be between 5 to 20.
F:M Ratio
F:M Ratio refers to the amount of organic matter (food) available to the microorganisms in the system to the amount of microbial biomass present.
Symbol: FM
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
Influent Substrate Concentration h
Influent Substrate Concentration h refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant.
Symbol: Sh
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
MLVSS Hydraulic Retention Time
MLVSS Hydraulic Retention Time refers to the amount of active microbial biomass, which is crucial for the biological degradation of organic pollutants.
Symbol: Xh
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other Formulas to find Hydraulic Retention Time in Seconds

​Go Hydraulic Retention Time given Volume of Rapid Mix Basin
θs=VrapidQFr'

Other formulas in Hydraulic Retention Time category

​Go Hydraulic Retention Time given Volume Required for Anaerobic Digester
θh=(VTQs)

How to Evaluate Hydraulic Retention Time given Food to Microorganism Ratio?

Hydraulic Retention Time given Food to Microorganism Ratio evaluator uses Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time) to evaluate the Hydraulic Retention Time in Seconds, The Hydraulic Retention Time given Food to Microorganism Ratio formula is defined as the measure of the average length of time that a soluble compound remains in a constructed bioreactor. Hydraulic Retention Time in Seconds is denoted by θs symbol.

How to evaluate Hydraulic Retention Time given Food to Microorganism Ratio using this online evaluator? To use this online evaluator for Hydraulic Retention Time given Food to Microorganism Ratio, enter F:M Ratio (FM), Influent Substrate Concentration h (Sh) & MLVSS Hydraulic Retention Time (Xh) and hit the calculate button.

FAQs on Hydraulic Retention Time given Food to Microorganism Ratio

What is the formula to find Hydraulic Retention Time given Food to Microorganism Ratio?
The formula of Hydraulic Retention Time given Food to Microorganism Ratio is expressed as Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time). Here is an example- 7.122507 = 2.31481481481481E-06/(0.05*6.5E-06).
How to calculate Hydraulic Retention Time given Food to Microorganism Ratio?
With F:M Ratio (FM), Influent Substrate Concentration h (Sh) & MLVSS Hydraulic Retention Time (Xh) we can find Hydraulic Retention Time given Food to Microorganism Ratio using the formula - Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time).
What are the other ways to Calculate Hydraulic Retention Time in Seconds?
Here are the different ways to Calculate Hydraulic Retention Time in Seconds-
  • Hydraulic Retention Time in Seconds=Volume of Rapid Mix Basin/Francis Discharge with Suppressed EndOpenImg
Can the Hydraulic Retention Time given Food to Microorganism Ratio be negative?
Yes, the Hydraulic Retention Time given Food to Microorganism Ratio, measured in Time can be negative.
Which unit is used to measure Hydraulic Retention Time given Food to Microorganism Ratio?
Hydraulic Retention Time given Food to Microorganism Ratio is usually measured using the Second[s] for Time. Millisecond[s], Microsecond[s], Nanosecond[s] are the few other units in which Hydraulic Retention Time given Food to Microorganism Ratio can be measured.
Copied!