Humid Heat of Air based on Adiabatic Saturation Temperature Formula

Fx Copy
LaTeX Copy
Humid Heat -The Heat capacity of 1Kg dry gas/air and whatever vapour/moisture contained in it. The heat capacity of humid air, expressed per unit mass of dry air in the mixture. Check FAQs
Cs=YS'-Y'TG-TSλS
Cs - Humid Heat?YS' - Saturated Exit Air Humidity?Y' - Inlet Air Humidity?TG - Temperature of Air?TS - Adiabatic Saturation Temperature?λS - Heat of Vaporization at Adiabatic Saturation Temp?

Humid Heat of Air based on Adiabatic Saturation Temperature Example

With values
With units
Only example

Here is how the Humid Heat of Air based on Adiabatic Saturation Temperature equation looks like with Values.

Here is how the Humid Heat of Air based on Adiabatic Saturation Temperature equation looks like with Units.

Here is how the Humid Heat of Air based on Adiabatic Saturation Temperature equation looks like.

0.66Edit=0.0172Edit-0.015Edit30Edit-22.5Edit2250Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Humid Heat of Air based on Adiabatic Saturation Temperature

Humid Heat of Air based on Adiabatic Saturation Temperature Solution

Follow our step by step solution on how to calculate Humid Heat of Air based on Adiabatic Saturation Temperature?

FIRST Step Consider the formula
Cs=YS'-Y'TG-TSλS
Next Step Substitute values of Variables
Cs=0.0172kg/kg of air-0.015kg/kg of air30°C-22.5°C2250kJ/kg
Next Step Convert Units
Cs=0.0172kg/kg of air-0.015kg/kg of air303.15K-295.65K2.3E+6J/kg
Next Step Prepare to Evaluate
Cs=0.0172-0.015303.15-295.652.3E+6
Next Step Evaluate
Cs=660J/(kg*K)
LAST Step Convert to Output's Unit
Cs=0.66kJ/kg*K

Humid Heat of Air based on Adiabatic Saturation Temperature Formula Elements

Variables
Humid Heat
Humid Heat -The Heat capacity of 1Kg dry gas/air and whatever vapour/moisture contained in it. The heat capacity of humid air, expressed per unit mass of dry air in the mixture.
Symbol: Cs
Measurement: Specific Heat CapacityUnit: kJ/kg*K
Note: Value should be greater than 0.
Saturated Exit Air Humidity
Saturated exit air humidity is the level of water vapor in air that has reached its saturation point, often expressed as the maximum amount of moisture the air can hold at a specific temperature.
Symbol: YS'
Measurement: Specific HumidityUnit: kg/kg of air
Note: Value should be greater than -1E-08.
Inlet Air Humidity
Inlet Air Humidity refers to the actual amount of water vapor present in a unit volume of incoming air.
Symbol: Y'
Measurement: Specific HumidityUnit: kg/kg of air
Note: Value should be greater than -1E-08.
Temperature of Air
The Temperature of Air is defined as the temperature at which the air-water mixture properties in humidification are calculated.
Symbol: TG
Measurement: TemperatureUnit: °C
Note: Value should be greater than -273.15.
Adiabatic Saturation Temperature
Adiabatic saturation temperature is the temperature achieved when moist air undergoes an adiabatic process while being saturated with water vapor.
Symbol: TS
Measurement: TemperatureUnit: °C
Note: Value should be greater than -273.15.
Heat of Vaporization at Adiabatic Saturation Temp
The heat of vaporization at adiabatic saturation temperature is the energy required per unit mass to convert liquid water into vapor during an adiabatic process.
Symbol: λS
Measurement: Latent HeatUnit: kJ/kg
Note: Value should be greater than 0.

Other formulas in Adiabatic Saturation Temperature and Wet Bulb Temperature category

​Go Adiabatic Saturation Temperature
TS=TG-(YS'-Y')(λSCs)
​Go Air Inlet Temperature based on Adiabatic Saturation Temperature
TG=(YS'-Y')(λSCs)+TS
​Go Latent Heat of Air based on Adiabatic Saturation Temperature
λS=TG-TSYS'-Y'Cs
​Go Saturated Exit Air Humidity based on Adiabatic Saturation Temperature
YS'=(TG-TS)(CsλS)+Y'

How to Evaluate Humid Heat of Air based on Adiabatic Saturation Temperature?

Humid Heat of Air based on Adiabatic Saturation Temperature evaluator uses Humid Heat = (Saturated Exit Air Humidity-Inlet Air Humidity)/(Temperature of Air-Adiabatic Saturation Temperature)*Heat of Vaporization at Adiabatic Saturation Temp to evaluate the Humid Heat, The Humid Heat of Air based on Adiabatic Saturation Temperature formula is defined as Humid Heat of Air calculated based on the saturation temperature and saturated exit air humidity for an adiabatic process. Humid Heat is denoted by Cs symbol.

How to evaluate Humid Heat of Air based on Adiabatic Saturation Temperature using this online evaluator? To use this online evaluator for Humid Heat of Air based on Adiabatic Saturation Temperature, enter Saturated Exit Air Humidity (YS'), Inlet Air Humidity (Y'), Temperature of Air (TG), Adiabatic Saturation Temperature (TS) & Heat of Vaporization at Adiabatic Saturation Temp S) and hit the calculate button.

FAQs on Humid Heat of Air based on Adiabatic Saturation Temperature

What is the formula to find Humid Heat of Air based on Adiabatic Saturation Temperature?
The formula of Humid Heat of Air based on Adiabatic Saturation Temperature is expressed as Humid Heat = (Saturated Exit Air Humidity-Inlet Air Humidity)/(Temperature of Air-Adiabatic Saturation Temperature)*Heat of Vaporization at Adiabatic Saturation Temp. Here is an example- 0.00066 = (0.0172-0.015)/(303.15-295.65)*2250000.
How to calculate Humid Heat of Air based on Adiabatic Saturation Temperature?
With Saturated Exit Air Humidity (YS'), Inlet Air Humidity (Y'), Temperature of Air (TG), Adiabatic Saturation Temperature (TS) & Heat of Vaporization at Adiabatic Saturation Temp S) we can find Humid Heat of Air based on Adiabatic Saturation Temperature using the formula - Humid Heat = (Saturated Exit Air Humidity-Inlet Air Humidity)/(Temperature of Air-Adiabatic Saturation Temperature)*Heat of Vaporization at Adiabatic Saturation Temp.
Can the Humid Heat of Air based on Adiabatic Saturation Temperature be negative?
No, the Humid Heat of Air based on Adiabatic Saturation Temperature, measured in Specific Heat Capacity cannot be negative.
Which unit is used to measure Humid Heat of Air based on Adiabatic Saturation Temperature?
Humid Heat of Air based on Adiabatic Saturation Temperature is usually measured using the Kilojoule per Kilogram per K[kJ/kg*K] for Specific Heat Capacity. Joule per Kilogram per K[kJ/kg*K], Joule per Kilogram per Celcius[kJ/kg*K], Kilojoule per Kilogram per Celcius[kJ/kg*K] are the few other units in which Humid Heat of Air based on Adiabatic Saturation Temperature can be measured.
Copied!