Height of tower in adiabatic humidification Formula

Fx Copy
LaTeX Copy
Height of the tower is the total length of the tower from the top to the bottom. Check FAQs
Z=(Gky)ln(Yi-Y1Yi-Y2)
Z - Height?G - Mass Velocity of Air?ky - Gas Phase Mass Transfer Coefficient?Yi - Absolute Humidity at Final Temperature?Y1 - Humidity of air at entry?Y2 - Humidity of air at exit?

Height of tower in adiabatic humidification Example

With values
With units
Only example

Here is how the Height of tower in adiabatic humidification equation looks like with Values.

Here is how the Height of tower in adiabatic humidification equation looks like with Units.

Here is how the Height of tower in adiabatic humidification equation looks like.

0.0401Edit=(18Edit90Edit)ln(60Edit-5Edit60Edit-15Edit)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Height of tower in adiabatic humidification

Height of tower in adiabatic humidification Solution

Follow our step by step solution on how to calculate Height of tower in adiabatic humidification?

FIRST Step Consider the formula
Z=(Gky)ln(Yi-Y1Yi-Y2)
Next Step Substitute values of Variables
Z=(1890mol/s*m²)ln(60-560-15)
Next Step Prepare to Evaluate
Z=(1890)ln(60-560-15)
Next Step Evaluate
Z=0.0401341390924303m
LAST Step Rounding Answer
Z=0.0401m

Height of tower in adiabatic humidification Formula Elements

Variables
Functions
Height
Height of the tower is the total length of the tower from the top to the bottom.
Symbol: Z
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Mass Velocity of Air
Mass velocity of air is the amount of air travelling per unit area in a second.
Symbol: G
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Gas Phase Mass Transfer Coefficient
Gas phase mass transfer coefficient is a diffusion rate constant that relates the mass transfer rate, mass transfer area, and concentration change as driving force.
Symbol: ky
Measurement: Molar Flux of Diffusing ComponentUnit: mol/s*m²
Note: Value can be positive or negative.
Absolute Humidity at Final Temperature
Absolute humidity at final temperature is the quality of water vapor in the wet air of unit volume at the final equilibrium air temperature.
Symbol: Yi
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Humidity of air at entry
The humidity of air at entry is the quantity of water vapor at wet air in the entrance of the tower.
Symbol: Y1
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Humidity of air at exit
Humidity of air at exit is the quantity of water vapor at wet air in the exit of the tower.
Symbol: Y2
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other formulas in Humidification category

​Go Enthalpy of evaporation for water in humidification
hfg=hConv(T∞-Tw)kL(Pw-P∞)
​Go Convective mass transfer coefficient in humidification
kL=hConv(T∞-Tw)hfg(Pw-P∞)
​Go Liquid layer temperature in dehumidification
Tl=ti-((hg(Tg-ti))+hfgky(Yg-Yi)h1)
​Go Gas phase heat transfer coefficient in dehumidification
hg=(h1(ti-Tl))-(hfgky(Yg-Yi))Tg-ti

How to Evaluate Height of tower in adiabatic humidification?

Height of tower in adiabatic humidification evaluator uses Height = (Mass Velocity of Air/Gas Phase Mass Transfer Coefficient)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit)) to evaluate the Height, The Height of tower in adiabatic humidification formula is defined as the length of the tower required for the abiotic humidification of the water. Height is denoted by Z symbol.

How to evaluate Height of tower in adiabatic humidification using this online evaluator? To use this online evaluator for Height of tower in adiabatic humidification, enter Mass Velocity of Air (G), Gas Phase Mass Transfer Coefficient (ky), Absolute Humidity at Final Temperature (Yi), Humidity of air at entry (Y1) & Humidity of air at exit (Y2) and hit the calculate button.

FAQs on Height of tower in adiabatic humidification

What is the formula to find Height of tower in adiabatic humidification?
The formula of Height of tower in adiabatic humidification is expressed as Height = (Mass Velocity of Air/Gas Phase Mass Transfer Coefficient)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit)). Here is an example- 0.040134 = (18/90)*ln((60-5)/(60-15)).
How to calculate Height of tower in adiabatic humidification?
With Mass Velocity of Air (G), Gas Phase Mass Transfer Coefficient (ky), Absolute Humidity at Final Temperature (Yi), Humidity of air at entry (Y1) & Humidity of air at exit (Y2) we can find Height of tower in adiabatic humidification using the formula - Height = (Mass Velocity of Air/Gas Phase Mass Transfer Coefficient)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit)). This formula also uses Natural Logarithm (ln) function(s).
Can the Height of tower in adiabatic humidification be negative?
Yes, the Height of tower in adiabatic humidification, measured in Length can be negative.
Which unit is used to measure Height of tower in adiabatic humidification?
Height of tower in adiabatic humidification is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Height of tower in adiabatic humidification can be measured.
Copied!