Height of Transfer Unit is a measure of the effectiveness of mass transfer between two phases (e.g., gas-liquid or liquid-liquid) in a separation or reaction process. Check FAQs
HOG=GmKGaP
HOG - Height of Transfer Unit?Gm - Molar Gas Flowrate?KG - Overall Gas Phase Mass Transfer Coefficient?a - Interfacial Area per Volume?P - Total Pressure?

Height of Overall Gas Phase Transfer Unit in Packed Column Example

With values
With units
Only example

Here is how the Height of Overall Gas Phase Transfer Unit in Packed Column equation looks like with Values.

Here is how the Height of Overall Gas Phase Transfer Unit in Packed Column equation looks like with Units.

Here is how the Height of Overall Gas Phase Transfer Unit in Packed Column equation looks like.

0.613Edit=2.0318Edit1.2358Edit0.1788Edit15Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Height of Overall Gas Phase Transfer Unit in Packed Column

Height of Overall Gas Phase Transfer Unit in Packed Column Solution

Follow our step by step solution on how to calculate Height of Overall Gas Phase Transfer Unit in Packed Column?

FIRST Step Consider the formula
HOG=GmKGaP
Next Step Substitute values of Variables
HOG=2.0318mol/s*m²1.2358m/s0.178815Pa
Next Step Prepare to Evaluate
HOG=2.03181.23580.178815
Next Step Evaluate
HOG=0.612991674629643m
LAST Step Rounding Answer
HOG=0.613m

Height of Overall Gas Phase Transfer Unit in Packed Column Formula Elements

Variables
Height of Transfer Unit
Height of Transfer Unit is a measure of the effectiveness of mass transfer between two phases (e.g., gas-liquid or liquid-liquid) in a separation or reaction process.
Symbol: HOG
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Molar Gas Flowrate
Molar Gas Flowrate is defined as the Molar flowrate per unit cross sectional area of the gaseous component.
Symbol: Gm
Measurement: Molar Flux of Diffusing ComponentUnit: mol/s*m²
Note: Value should be greater than 0.
Overall Gas Phase Mass Transfer Coefficient
Overall Gas Phase Mass Transfer Coefficient describes the rate at which mass is transferred between the gas and liquid phases within the packed column.
Symbol: KG
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Interfacial Area per Volume
Interfacial Area per Volume refers to the surface area of the interface between the two phases (usually a liquid and a gas) per unit volume of the packing material.
Symbol: a
Measurement: AreaUnit:
Note: Value should be greater than 0.
Total Pressure
Total Pressure is the actually pressure at which the system is operating a particular process.
Symbol: P
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.

Other formulas in Packed Column Designing category

​Go Effective Interfacial Area of Packing using Onda's Method
aW=a(1-exp((-1.45((σcσL)0.75)(LWaμL)0.1)((LW)2a(ρL)2[g])-0.05)(LW2ρLaσL)0.2)
​Go Liquid Mass Film Coefficient in Packed Columns
KL=0.0051((LWVPaWμL)23)((μLρLDc)-12)((adpVP)0.4)(μL[g]ρL)13
​Go Log Mean Driving Force Based on Mole Fraction
Δylm=y1-y2ln(y1-yey2-ye)
​Go Number of Transfer Units for Dilute System in Packed Column
Nog=y1-y2Δylm

How to Evaluate Height of Overall Gas Phase Transfer Unit in Packed Column?

Height of Overall Gas Phase Transfer Unit in Packed Column evaluator uses Height of Transfer Unit = (Molar Gas Flowrate)/(Overall Gas Phase Mass Transfer Coefficient*Interfacial Area per Volume*Total Pressure) to evaluate the Height of Transfer Unit, The Height Of Overall Gas Phase Transfer Unit in Packed Column formula is defined as the height (or length) of a theoretical stage in a separation or reaction process, such that the concentration or composition change across this stage is equal to one transfer unit. Height of Transfer Unit is denoted by HOG symbol.

How to evaluate Height of Overall Gas Phase Transfer Unit in Packed Column using this online evaluator? To use this online evaluator for Height of Overall Gas Phase Transfer Unit in Packed Column, enter Molar Gas Flowrate (Gm), Overall Gas Phase Mass Transfer Coefficient (KG), Interfacial Area per Volume (a) & Total Pressure (P) and hit the calculate button.

FAQs on Height of Overall Gas Phase Transfer Unit in Packed Column

What is the formula to find Height of Overall Gas Phase Transfer Unit in Packed Column?
The formula of Height of Overall Gas Phase Transfer Unit in Packed Column is expressed as Height of Transfer Unit = (Molar Gas Flowrate)/(Overall Gas Phase Mass Transfer Coefficient*Interfacial Area per Volume*Total Pressure). Here is an example- 0.612992 = (2.0318103)/(1.2358*0.1788089*15).
How to calculate Height of Overall Gas Phase Transfer Unit in Packed Column?
With Molar Gas Flowrate (Gm), Overall Gas Phase Mass Transfer Coefficient (KG), Interfacial Area per Volume (a) & Total Pressure (P) we can find Height of Overall Gas Phase Transfer Unit in Packed Column using the formula - Height of Transfer Unit = (Molar Gas Flowrate)/(Overall Gas Phase Mass Transfer Coefficient*Interfacial Area per Volume*Total Pressure).
Can the Height of Overall Gas Phase Transfer Unit in Packed Column be negative?
No, the Height of Overall Gas Phase Transfer Unit in Packed Column, measured in Length cannot be negative.
Which unit is used to measure Height of Overall Gas Phase Transfer Unit in Packed Column?
Height of Overall Gas Phase Transfer Unit in Packed Column is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Height of Overall Gas Phase Transfer Unit in Packed Column can be measured.
Copied!