Height of Liquid Crest over Weir Formula

Fx Copy
LaTeX Copy
Weir Crest is designed to have a specific height for the liquid flow across the tray. Check FAQs
how=(7501000)((LwlwρL)23)
how - Weir Crest?Lw - Liquid Mass Flowrate?lw - Weir Length?ρL - Liquid Density?

Height of Liquid Crest over Weir Example

With values
With units
Only example

Here is how the Height of Liquid Crest over Weir equation looks like with Values.

Here is how the Height of Liquid Crest over Weir equation looks like with Units.

Here is how the Height of Liquid Crest over Weir equation looks like.

0.0227Edit=(7501000)((12.856Edit2.452Edit995Edit)23)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Height of Liquid Crest over Weir

Height of Liquid Crest over Weir Solution

Follow our step by step solution on how to calculate Height of Liquid Crest over Weir?

FIRST Step Consider the formula
how=(7501000)((LwlwρL)23)
Next Step Substitute values of Variables
how=(7501000)((12.856kg/s2.452m995kg/m³)23)
Next Step Prepare to Evaluate
how=(7501000)((12.8562.452995)23)
Next Step Evaluate
how=0.0227109939449152m
LAST Step Rounding Answer
how=0.0227m

Height of Liquid Crest over Weir Formula Elements

Variables
Weir Crest
Weir Crest is designed to have a specific height for the liquid flow across the tray.
Symbol: how
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Liquid Mass Flowrate
Liquid Mass Flowrate is the mass flow rate of the liquid component in the column.
Symbol: Lw
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Weir Length
The weir length refers to the length of support strips which plays a significant role in controlling liquid distribution, within the column.
Symbol: lw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Liquid Density
Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Symbol: ρL
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.

Other formulas in Distillation Tower Design category

​Go Clearance Area under Downcomer given Weir Length and Apron Height
Aap=haplw
​Go Active Area given Gas Volumetric Flow and Flow Velocity
Aa=Gvfduf
​Go Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
Dc=(4VWπWmax)12
​Go Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
Dc=4VWπρVUv

How to Evaluate Height of Liquid Crest over Weir?

Height of Liquid Crest over Weir evaluator uses Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3)) to evaluate the Weir Crest, The Height of Liquid Crest over Weir formula is defined as the boundary for the liquid flow across the tray. It plays a crucial role in controlling the flow of liquid on the tray. Weir Crest is denoted by how symbol.

How to evaluate Height of Liquid Crest over Weir using this online evaluator? To use this online evaluator for Height of Liquid Crest over Weir, enter Liquid Mass Flowrate (Lw), Weir Length (lw) & Liquid Density L) and hit the calculate button.

FAQs on Height of Liquid Crest over Weir

What is the formula to find Height of Liquid Crest over Weir?
The formula of Height of Liquid Crest over Weir is expressed as Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3)). Here is an example- 0.022711 = (750/1000)*((12.856/(2.452*995))^(2/3)).
How to calculate Height of Liquid Crest over Weir?
With Liquid Mass Flowrate (Lw), Weir Length (lw) & Liquid Density L) we can find Height of Liquid Crest over Weir using the formula - Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3)).
Can the Height of Liquid Crest over Weir be negative?
Yes, the Height of Liquid Crest over Weir, measured in Length can be negative.
Which unit is used to measure Height of Liquid Crest over Weir?
Height of Liquid Crest over Weir is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Height of Liquid Crest over Weir can be measured.
Copied!