Height of Drop given Allowable Load for Drop Hammer Driven Piles Formula

Fx Copy
LaTeX Copy
Height of Drop is the vertical distance over which a drop hammer falls to compact soil or other materials in field compaction tests. Check FAQs
Hd=Pa(p+1)2Wh
Hd - Height of Drop?Pa - Allowable Pile Load?p - Penetration per Blow?Wh - Hammer Weight?

Height of Drop given Allowable Load for Drop Hammer Driven Piles Example

With values
With units
Only example

Here is how the Height of Drop given Allowable Load for Drop Hammer Driven Piles equation looks like with Values.

Here is how the Height of Drop given Allowable Load for Drop Hammer Driven Piles equation looks like with Units.

Here is how the Height of Drop given Allowable Load for Drop Hammer Driven Piles equation looks like.

0.3Edit=12.09Edit(2Edit+1)220.19Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Height of Drop given Allowable Load for Drop Hammer Driven Piles

Height of Drop given Allowable Load for Drop Hammer Driven Piles Solution

Follow our step by step solution on how to calculate Height of Drop given Allowable Load for Drop Hammer Driven Piles?

FIRST Step Consider the formula
Hd=Pa(p+1)2Wh
Next Step Substitute values of Variables
Hd=12.09kg(2mm+1)220.19kg
Next Step Convert Units
Hd=12.09kg(0.002m+1)220.19kg
Next Step Prepare to Evaluate
Hd=12.09(0.002+1)220.19
Next Step Evaluate
Hd=0.300004457652303m
LAST Step Rounding Answer
Hd=0.3m

Height of Drop given Allowable Load for Drop Hammer Driven Piles Formula Elements

Variables
Height of Drop
Height of Drop is the vertical distance over which a drop hammer falls to compact soil or other materials in field compaction tests.
Symbol: Hd
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Allowable Pile Load
Allowable Pile Load is the maximum load that a pile can safely support without experiencing unacceptable levels of settlement or failure.
Symbol: Pa
Measurement: WeightUnit: kg
Note: Value should be greater than 0.
Penetration per Blow
Penetration per Blow is the measure of penetration of pile on each blow of hammer.
Symbol: p
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Hammer Weight
Hammer Weight is the weight of the hammer used in dynamic pile driving.
Symbol: Wh
Measurement: WeightUnit: kg
Note: Value should be greater than 0.

Other formulas in Allowable Load on Piles category

​Go Allowable Load for Drop Hammer Driven Piles
Pa=2WhHdp+1
​Go Weight of Hammer given Allowable Load for Steam Hammer Driven Piles
Ws=Pa(p+0.1)2Hd
​Go Weight of Hammer given Allowable Load for Drop Hammer Driven Piles
Wh=Pa(p+1)2Hd
​Go Height of Drop given Allowable Load for Steam Hammer Driven Piles
Hsd=Pa(p+0.1)2Wh

How to Evaluate Height of Drop given Allowable Load for Drop Hammer Driven Piles?

Height of Drop given Allowable Load for Drop Hammer Driven Piles evaluator uses Height of Drop = (Allowable Pile Load*(Penetration per Blow+1))/(2*Hammer Weight) to evaluate the Height of Drop, The Height of Drop given Allowable Load for Drop Hammer Driven Piles formula is defined as vertical distance through which a drop hammer is allowed to fall freely before striking the pile, considering allowable load for drop hammer driven piles. Height of Drop is denoted by Hd symbol.

How to evaluate Height of Drop given Allowable Load for Drop Hammer Driven Piles using this online evaluator? To use this online evaluator for Height of Drop given Allowable Load for Drop Hammer Driven Piles, enter Allowable Pile Load (Pa), Penetration per Blow (p) & Hammer Weight (Wh) and hit the calculate button.

FAQs on Height of Drop given Allowable Load for Drop Hammer Driven Piles

What is the formula to find Height of Drop given Allowable Load for Drop Hammer Driven Piles?
The formula of Height of Drop given Allowable Load for Drop Hammer Driven Piles is expressed as Height of Drop = (Allowable Pile Load*(Penetration per Blow+1))/(2*Hammer Weight). Here is an example- 2.998559 = (12.09*(0.002+1))/(2*20.19).
How to calculate Height of Drop given Allowable Load for Drop Hammer Driven Piles?
With Allowable Pile Load (Pa), Penetration per Blow (p) & Hammer Weight (Wh) we can find Height of Drop given Allowable Load for Drop Hammer Driven Piles using the formula - Height of Drop = (Allowable Pile Load*(Penetration per Blow+1))/(2*Hammer Weight).
Can the Height of Drop given Allowable Load for Drop Hammer Driven Piles be negative?
No, the Height of Drop given Allowable Load for Drop Hammer Driven Piles, measured in Length cannot be negative.
Which unit is used to measure Height of Drop given Allowable Load for Drop Hammer Driven Piles?
Height of Drop given Allowable Load for Drop Hammer Driven Piles is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Height of Drop given Allowable Load for Drop Hammer Driven Piles can be measured.
Copied!