Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes Formula

Fx Copy
LaTeX Copy
Heat Transfer Coefficient for Forced Convection is the heat transferred per unit area per degree celcius. Check FAQs
h=(2.54((ΔTx)3)exp(p1.551))
h - Heat Transfer Coefficient for Forced Convection?ΔTx - Excess Temperature?p - System Pressure in Vertical Tubes?

Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes Example

With values
With units
Only example

Here is how the Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes equation looks like with Values.

Here is how the Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes equation looks like with Units.

Here is how the Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes equation looks like.

29.0456Edit=(2.54((2.25Edit)3)exp(0.0061Edit1.551))
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Heat Transfer » fx Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes

Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes Solution

Follow our step by step solution on how to calculate Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes?

FIRST Step Consider the formula
h=(2.54((ΔTx)3)exp(p1.551))
Next Step Substitute values of Variables
h=(2.54((2.25°C)3)exp(0.0061MPa1.551))
Next Step Convert Units
h=(2.54((2.25K)3)exp(0.0061MPa1.551))
Next Step Prepare to Evaluate
h=(2.54((2.25)3)exp(0.00611.551))
Next Step Evaluate
h=29.0456384847018W/m²*K
Next Step Convert to Output's Unit
h=29.0456384847018W/m²*°C
LAST Step Rounding Answer
h=29.0456W/m²*°C

Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes Formula Elements

Variables
Functions
Heat Transfer Coefficient for Forced Convection
Heat Transfer Coefficient for Forced Convection is the heat transferred per unit area per degree celcius.
Symbol: h
Measurement: Heat Transfer CoefficientUnit: W/m²*°C
Note: Value can be positive or negative.
Excess Temperature
Excess Temperature is defined as the temperature difference between heat source and saturation temperature of the fluid.
Symbol: ΔTx
Measurement: Temperature DifferenceUnit: °C
Note: Value should be greater than 0.
System Pressure in Vertical Tubes
System Pressure in Vertical Tubes is the force applied perpendicular to the surface of an object per unit area over which that force is distributed.
Symbol: p
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
exp
n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable.
Syntax: exp(Number)

Other formulas in Boiling category

​Go Excess Temperature in Boiling
Texcess=Tsurface-TSat
​Go Critical Heat Flux by Zuber
qMax=((0.149Lvρv)((σ[g])(ρL-ρv)ρv2)14)
​Go Correlation for Heat Flux proposed by Mostinski
hb=0.00341(Pc2.3)(Te2.33)(Pr0.566)
​Go Heat Flux in Fully Developed Boiling State for Pressure upto 0.7 Megapascal
qrate=2.253A((ΔTx)3.96)

How to Evaluate Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes?

Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes evaluator uses Heat Transfer Coefficient for Forced Convection = (2.54*((Excess Temperature)^3)*exp((System Pressure in Vertical Tubes)/1.551)) to evaluate the Heat Transfer Coefficient for Forced Convection, The Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes formula is defined as a function of excess temperature and system pressure. Heat Transfer Coefficient for Forced Convection is denoted by h symbol.

How to evaluate Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes using this online evaluator? To use this online evaluator for Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes, enter Excess Temperature (ΔTx) & System Pressure in Vertical Tubes (p) and hit the calculate button.

FAQs on Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes

What is the formula to find Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes?
The formula of Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes is expressed as Heat Transfer Coefficient for Forced Convection = (2.54*((Excess Temperature)^3)*exp((System Pressure in Vertical Tubes)/1.551)). Here is an example- 29.04564 = (2.54*((2.25)^3)*exp((6070)/1.551)).
How to calculate Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes?
With Excess Temperature (ΔTx) & System Pressure in Vertical Tubes (p) we can find Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes using the formula - Heat Transfer Coefficient for Forced Convection = (2.54*((Excess Temperature)^3)*exp((System Pressure in Vertical Tubes)/1.551)). This formula also uses Exponential Growth (exp) function(s).
Can the Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes be negative?
Yes, the Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes, measured in Heat Transfer Coefficient can be negative.
Which unit is used to measure Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes?
Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes is usually measured using the Watt per Square Meter per Celcius[W/m²*°C] for Heat Transfer Coefficient. Watt per Square Meter per Kelvin[W/m²*°C], Joule per Second per Square Meter per Kelvin[W/m²*°C], Kilocalorie (IT) per Hour per Square Foot per Celcius[W/m²*°C] are the few other units in which Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes can be measured.
Copied!