Corrected Latent Heat of Vaporization is defined as the heat required to change one mole of liquid at its boiling point under standard atmospheric pressure. Check FAQs
h'fg=(hfg+0.68c(TSat-Tw))
h'fg - Corrected Latent Heat of Vaporization?hfg - Latent Heat of Vaporization?c - Specific Heat Capacity?TSat - Saturation Temperature?Tw - Plate Surface Temperature?

Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film Example

With values
With units
Only example

Here is how the Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film equation looks like with Values.

Here is how the Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film equation looks like with Units.

Here is how the Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film equation looks like.

3.1E+6Edit=(2.3E+6Edit+0.684184Edit(373Edit-82Edit))
You are here -

Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film Solution

Follow our step by step solution on how to calculate Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film?

FIRST Step Consider the formula
h'fg=(hfg+0.68c(TSat-Tw))
Next Step Substitute values of Variables
h'fg=(2.3E+6J/kg+0.684184J/(kg*K)(373K-82K))
Next Step Prepare to Evaluate
h'fg=(2.3E+6+0.684184(373-82))
Next Step Evaluate
h'fg=3087929.92J/kg
LAST Step Rounding Answer
h'fg=3.1E+6J/kg

Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film Formula Elements

Variables
Corrected Latent Heat of Vaporization
Corrected Latent Heat of Vaporization is defined as the heat required to change one mole of liquid at its boiling point under standard atmospheric pressure.
Symbol: h'fg
Measurement: Latent HeatUnit: J/kg
Note: Value should be greater than 0.
Latent Heat of Vaporization
Latent Heat of Vaporization is defined as the heat required to change one mole of liquid at its boiling point under standard atmospheric pressure.
Symbol: hfg
Measurement: Latent HeatUnit: J/kg
Note: Value should be greater than 0.
Specific Heat Capacity
Specific Heat Capacity is the heat required to raise the temperature of the unit mass of a given substance by a given amount.
Symbol: c
Measurement: Specific Heat CapacityUnit: J/(kg*K)
Note: Value can be positive or negative.
Saturation Temperature
Saturation temperature is the temperature at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given pressure.
Symbol: TSat
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Plate Surface Temperature
Plate Surface Temperature is the temperature at the surface of the plate.
Symbol: Tw
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.

Other formulas in Condensation category

​Go Film Thickness given Mass Flow of Condensate
δ=(3μfρL(ρL-ρv)[g])13
​Go Condensation Number
Co=(h ̅)(((μf)2(k3)(ρf)(ρf-ρv)[g])13)
​Go Condensation Number for Vertical Plate
Co=1.47((Ref)-13)
​Go Condensation Number for Horizontal Cylinder
Co=1.514((Ref)-13)

How to Evaluate Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film?

Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film evaluator uses Corrected Latent Heat of Vaporization = (Latent Heat of Vaporization+0.68*Specific Heat Capacity*(Saturation Temperature-Plate Surface Temperature)) to evaluate the Corrected Latent Heat of Vaporization, Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film formula is defined as the sum of old latent heat and additional energy to cool the film below the saturation temperature. It is the function of latent heat of vaporization, specific heat capacity, saturation temperature and plate surface temperature. Corrected Latent Heat of Vaporization is denoted by h'fg symbol.

How to evaluate Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film using this online evaluator? To use this online evaluator for Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film, enter Latent Heat of Vaporization (hfg), Specific Heat Capacity (c), Saturation Temperature (TSat) & Plate Surface Temperature (Tw) and hit the calculate button.

FAQs on Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film

What is the formula to find Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film?
The formula of Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film is expressed as Corrected Latent Heat of Vaporization = (Latent Heat of Vaporization+0.68*Specific Heat Capacity*(Saturation Temperature-Plate Surface Temperature)). Here is an example- 3.1E+6 = (2260000+0.68*4184*(373-82)).
How to calculate Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film?
With Latent Heat of Vaporization (hfg), Specific Heat Capacity (c), Saturation Temperature (TSat) & Plate Surface Temperature (Tw) we can find Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film using the formula - Corrected Latent Heat of Vaporization = (Latent Heat of Vaporization+0.68*Specific Heat Capacity*(Saturation Temperature-Plate Surface Temperature)).
Can the Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film be negative?
No, the Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film, measured in Latent Heat cannot be negative.
Which unit is used to measure Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film?
Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film is usually measured using the Joule per Kilogram[J/kg] for Latent Heat. Kilojoule per Kilogram[J/kg], BTU per Pound[J/kg], Calorie per Gram[J/kg] are the few other units in which Heat Transfer Coefficient for Condensation on Flat Plate for Nonlinear Temperature Profile in Film can be measured.
Copied!