Heat rejected during cooling process Formula

Fx Copy
LaTeX Copy
Heat Rejected during Cooling Process is the heat released during any of the thermodynamic processes. Check FAQs
QR, Cooling=maCp(Tt'-T4)
QR, Cooling - Heat Rejected during Cooling Process?ma - Mass of Air?Cp - Specific Heat Capacity at Constant Pressure?Tt' - Actual End Temp of Isentropic Compression?T4 - Temperature at the end of Cooling Process?

Heat rejected during cooling process Example

With values
With units
Only example

Here is how the Heat rejected during cooling process equation looks like with Values.

Here is how the Heat rejected during cooling process equation looks like with Units.

Here is how the Heat rejected during cooling process equation looks like.

16.08Edit=120Edit1.005Edit(350Edit-342Edit)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Refrigeration and Air Conditioning » fx Heat rejected during cooling process

Heat rejected during cooling process Solution

Follow our step by step solution on how to calculate Heat rejected during cooling process?

FIRST Step Consider the formula
QR, Cooling=maCp(Tt'-T4)
Next Step Substitute values of Variables
QR, Cooling=120kg/min1.005kJ/kg*K(350K-342K)
Next Step Convert Units
QR, Cooling=2kg/s1005J/(kg*K)(350K-342K)
Next Step Prepare to Evaluate
QR, Cooling=21005(350-342)
Next Step Evaluate
QR, Cooling=16080J/kg
LAST Step Convert to Output's Unit
QR, Cooling=16.08kJ/kg

Heat rejected during cooling process Formula Elements

Variables
Heat Rejected during Cooling Process
Heat Rejected during Cooling Process is the heat released during any of the thermodynamic processes.
Symbol: QR, Cooling
Measurement: Specific EnergyUnit: kJ/kg
Note: Value can be positive or negative.
Mass of Air
Mass of Air is the amount of air present in a refrigeration system, which affects the cooling performance and overall efficiency of the system.
Symbol: ma
Measurement: Mass Flow RateUnit: kg/min
Note: Value should be greater than 0.
Specific Heat Capacity at Constant Pressure
Specific Heat Capacity at Constant Pressure is the amount of heat required to change the temperature of air in refrigeration systems by one degree Celsius.
Symbol: Cp
Measurement: Specific Heat CapacityUnit: kJ/kg*K
Note: Value can be positive or negative.
Actual End Temp of Isentropic Compression
Actual End Temp of Isentropic Compression is the final temperature of air at the end of an isentropic compression process in air refrigeration systems.
Symbol: Tt'
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Temperature at the end of Cooling Process
Temperature at the end of cooling process is the final temperature of the air after it has been cooled in an air refrigeration system.
Symbol: T4
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other formulas in Air Refrigeration category

​Go Energy Performance Ratio of Heat Pump
COPtheoretical=QdeliveredWper min
​Go Relative Coefficient of Performance
COPrelative=COPactualCOPtheoretical
​Go Theoretical Coefficient of Performance of Refrigerator
COPtheoretical=Qrefw
​Go Compression or Expansion Ratio
rp=P2P1

How to Evaluate Heat rejected during cooling process?

Heat rejected during cooling process evaluator uses Heat Rejected during Cooling Process = Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Temperature at the end of Cooling Process) to evaluate the Heat Rejected during Cooling Process, Heat rejected during cooling process formula is defined as the amount of heat energy transferred from the system to the surroundings during a cooling process, typically measured in joules, and is a critical parameter in refrigeration and air conditioning systems. Heat Rejected during Cooling Process is denoted by QR, Cooling symbol.

How to evaluate Heat rejected during cooling process using this online evaluator? To use this online evaluator for Heat rejected during cooling process, enter Mass of Air (ma), Specific Heat Capacity at Constant Pressure (Cp), Actual End Temp of Isentropic Compression (Tt') & Temperature at the end of Cooling Process (T4) and hit the calculate button.

FAQs on Heat rejected during cooling process

What is the formula to find Heat rejected during cooling process?
The formula of Heat rejected during cooling process is expressed as Heat Rejected during Cooling Process = Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Temperature at the end of Cooling Process). Here is an example- 0.01608 = 2*1005*(350-342).
How to calculate Heat rejected during cooling process?
With Mass of Air (ma), Specific Heat Capacity at Constant Pressure (Cp), Actual End Temp of Isentropic Compression (Tt') & Temperature at the end of Cooling Process (T4) we can find Heat rejected during cooling process using the formula - Heat Rejected during Cooling Process = Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Temperature at the end of Cooling Process).
Can the Heat rejected during cooling process be negative?
Yes, the Heat rejected during cooling process, measured in Specific Energy can be negative.
Which unit is used to measure Heat rejected during cooling process?
Heat rejected during cooling process is usually measured using the Kilojoule per Kilogram[kJ/kg] for Specific Energy. Joule per Kilogram[kJ/kg], Joule per Gram[kJ/kg], Joule per Centigram[kJ/kg] are the few other units in which Heat rejected during cooling process can be measured.
Copied!