Head at Control given Depth at Gauging Station Formula

Fx Copy
LaTeX Copy
Head at Control shown as a function of discharge Q. Check FAQs
Hc=hG-hcsf-Q22Q
Hc - Head at Control?hG - Depth at Gauging Station?hcsf - Cease-to-Flow Depth?Q2 - Terms of Order?Q - Discharge?

Head at Control given Depth at Gauging Station Example

With values
With units
Only example

Here is how the Head at Control given Depth at Gauging Station equation looks like with Values.

Here is how the Head at Control given Depth at Gauging Station equation looks like with Units.

Here is how the Head at Control given Depth at Gauging Station equation looks like.

0.05Edit=6.01Edit-0.1Edit-2.4Edit23Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Head at Control given Depth at Gauging Station

Head at Control given Depth at Gauging Station Solution

Follow our step by step solution on how to calculate Head at Control given Depth at Gauging Station?

FIRST Step Consider the formula
Hc=hG-hcsf-Q22Q
Next Step Substitute values of Variables
Hc=6.01m-0.1m-2.423m³/s
Next Step Prepare to Evaluate
Hc=6.01-0.1-2.423
Next Step Evaluate
Hc=0.0500000000000001m
LAST Step Rounding Answer
Hc=0.05m

Head at Control given Depth at Gauging Station Formula Elements

Variables
Head at Control
Head at Control shown as a function of discharge Q.
Symbol: Hc
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth at Gauging Station
Depth at Gauging Station where the hydraulics of a downstream control and a gauging station are considered.
Symbol: hG
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Cease-to-Flow Depth
Cease-to-Flow Depth when hydraulics of a downstream control and a gauging station are considered.
Symbol: hcsf
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Terms of Order
Terms of Order give the head loss between the gauging station and the control.
Symbol: Q2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Discharge
The Discharge refers to the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other formulas in Low Flow category

​Go Cease to Flow Depth given Depth at Gauging Station
hcsf=hG-Hc(Q)-Q22
​Go Depth at Gauging Station
hG=hcsf+Hc(Q)+Q22
​Go Discharge given Depth at Gauging Station
Q=hG-hcsf-Q22Hc

How to Evaluate Head at Control given Depth at Gauging Station?

Head at Control given Depth at Gauging Station evaluator uses Head at Control = (Depth at Gauging Station-Cease-to-Flow Depth-Terms of Order^2)/(Discharge) to evaluate the Head at Control, The Head at Control given Depth at Gauging Station formula is defined as the energy per unit weight of fluid at a gauging station's specified depth. Head at Control is denoted by Hc symbol.

How to evaluate Head at Control given Depth at Gauging Station using this online evaluator? To use this online evaluator for Head at Control given Depth at Gauging Station, enter Depth at Gauging Station (hG), Cease-to-Flow Depth (hcsf), Terms of Order (Q2) & Discharge (Q) and hit the calculate button.

FAQs on Head at Control given Depth at Gauging Station

What is the formula to find Head at Control given Depth at Gauging Station?
The formula of Head at Control given Depth at Gauging Station is expressed as Head at Control = (Depth at Gauging Station-Cease-to-Flow Depth-Terms of Order^2)/(Discharge). Here is an example- 50000 = (6.01-0.1-2.4^2)/(3).
How to calculate Head at Control given Depth at Gauging Station?
With Depth at Gauging Station (hG), Cease-to-Flow Depth (hcsf), Terms of Order (Q2) & Discharge (Q) we can find Head at Control given Depth at Gauging Station using the formula - Head at Control = (Depth at Gauging Station-Cease-to-Flow Depth-Terms of Order^2)/(Discharge).
Can the Head at Control given Depth at Gauging Station be negative?
Yes, the Head at Control given Depth at Gauging Station, measured in Length can be negative.
Which unit is used to measure Head at Control given Depth at Gauging Station?
Head at Control given Depth at Gauging Station is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Head at Control given Depth at Gauging Station can be measured.
Copied!