Half Scale Resistance for Series Type Ohmmeter Formula

Fx Copy
LaTeX Copy
Half Scale Resistance refers to the resistance value halfway between the maximum and minimum resistance of a variable resistor or potentiometer, typically used to calibrate or set reference points. Check FAQs
Rh=ER2IfR2+IfRm
Rh - Half Scale Resistance?E - Voltage Source?R2 - Zero Adjusting Resistance?If - Current Full Scale Reading?Rm - Meter Resistance?

Half Scale Resistance for Series Type Ohmmeter Example

With values
With units
Only example

Here is how the Half Scale Resistance for Series Type Ohmmeter equation looks like with Values.

Here is how the Half Scale Resistance for Series Type Ohmmeter equation looks like with Units.

Here is how the Half Scale Resistance for Series Type Ohmmeter equation looks like.

25.1351Edit=15.5Edit36Edit0.2Edit36Edit+0.2Edit75Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Half Scale Resistance for Series Type Ohmmeter

Half Scale Resistance for Series Type Ohmmeter Solution

Follow our step by step solution on how to calculate Half Scale Resistance for Series Type Ohmmeter?

FIRST Step Consider the formula
Rh=ER2IfR2+IfRm
Next Step Substitute values of Variables
Rh=15.5V36Ω0.2A36Ω+0.2A75Ω
Next Step Prepare to Evaluate
Rh=15.5360.236+0.275
Next Step Evaluate
Rh=25.1351351351351Ω
LAST Step Rounding Answer
Rh=25.1351Ω

Half Scale Resistance for Series Type Ohmmeter Formula Elements

Variables
Half Scale Resistance
Half Scale Resistance refers to the resistance value halfway between the maximum and minimum resistance of a variable resistor or potentiometer, typically used to calibrate or set reference points.
Symbol: Rh
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Voltage Source
Voltage Source refers to as a fundamental element that supplies electrical energy to a circuit.
Symbol: E
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Zero Adjusting Resistance
Zero Adjusting Resistance refers to a variable resistor used to calibrate or adjust the zero reading of a measuring instrument.
Symbol: R2
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Current Full Scale Reading
Current Full Scale Reading represents the maximum current that the ohmmeter will pass through the resistor when it's being measured at its highest resistance value.
Symbol: If
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Meter Resistance
Meter Resistance refers to the internal resistance of a measuring instrument. This resistance is inherent to the design of the instrument and affects the accuracy of measurements made by the device.
Symbol: Rm
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Series Type category

​Go Current Limiting Resistance for Series Type Ohmmeter
R1=Rh-(IfRmRhE)
​Go Shunt Adjustable Resistance for Series Type Ohmmeter
R2=IfRhRmE-(IfRh)

How to Evaluate Half Scale Resistance for Series Type Ohmmeter?

Half Scale Resistance for Series Type Ohmmeter evaluator uses Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance) to evaluate the Half Scale Resistance, The Half Scale Resistance for Series Type Ohmmeter formula is defined as the resistance value that would produce a half-scale deflection of the meter when connected in series with the meter movement and the unknown resistance being measured. Half Scale Resistance is denoted by Rh symbol.

How to evaluate Half Scale Resistance for Series Type Ohmmeter using this online evaluator? To use this online evaluator for Half Scale Resistance for Series Type Ohmmeter, enter Voltage Source (E), Zero Adjusting Resistance (R2), Current Full Scale Reading (If) & Meter Resistance (Rm) and hit the calculate button.

FAQs on Half Scale Resistance for Series Type Ohmmeter

What is the formula to find Half Scale Resistance for Series Type Ohmmeter?
The formula of Half Scale Resistance for Series Type Ohmmeter is expressed as Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance). Here is an example- 65.64706 = (15.5*36)/(0.2*36+0.2*75).
How to calculate Half Scale Resistance for Series Type Ohmmeter?
With Voltage Source (E), Zero Adjusting Resistance (R2), Current Full Scale Reading (If) & Meter Resistance (Rm) we can find Half Scale Resistance for Series Type Ohmmeter using the formula - Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance).
Can the Half Scale Resistance for Series Type Ohmmeter be negative?
No, the Half Scale Resistance for Series Type Ohmmeter, measured in Electric Resistance cannot be negative.
Which unit is used to measure Half Scale Resistance for Series Type Ohmmeter?
Half Scale Resistance for Series Type Ohmmeter is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Half Scale Resistance for Series Type Ohmmeter can be measured.
Copied!