Gas phase heat transfer coefficient in dehumidification Formula

Fx Copy
LaTeX Copy
Gas Phase Heat Transfer Coefficient is the heat transfer in gas per unit area in kelvin. Check FAQs
hg=(h1(ti-Tl))-(hfgky(Yg-Yi))Tg-ti
hg - Gas Phase Heat Transfer Coefficient?h1 - Liquid Phase Heat Transfer Coefficient?ti - Inside Temperature?Tl - Liquid layer temperature?hfg - Enthalpy of Evaporation?ky - Gas Phase Mass Transfer Coefficient?Yg - Absolute Humidity of Air(tg)?Yi - Absolute Humidity (ti)?Tg - Bulk Gas Temperature?

Gas phase heat transfer coefficient in dehumidification Example

With values
With units
Only example

Here is how the Gas phase heat transfer coefficient in dehumidification equation looks like with Values.

Here is how the Gas phase heat transfer coefficient in dehumidification equation looks like with Units.

Here is how the Gas phase heat transfer coefficient in dehumidification equation looks like.

-1125.1636Edit=(10.8Edit(353Edit-20Edit))-(90Edit90Edit(16Edit-50.7Edit))100Edit-353Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Gas phase heat transfer coefficient in dehumidification

Gas phase heat transfer coefficient in dehumidification Solution

Follow our step by step solution on how to calculate Gas phase heat transfer coefficient in dehumidification?

FIRST Step Consider the formula
hg=(h1(ti-Tl))-(hfgky(Yg-Yi))Tg-ti
Next Step Substitute values of Variables
hg=(10.8W/m²*K(353K-20))-(90J/kg*K90mol/s*m²(16-50.7))100-353K
Next Step Prepare to Evaluate
hg=(10.8(353-20))-(9090(16-50.7))100-353
Next Step Evaluate
hg=-1125.16363636364W/m²*K
LAST Step Rounding Answer
hg=-1125.1636W/m²*K

Gas phase heat transfer coefficient in dehumidification Formula Elements

Variables
Gas Phase Heat Transfer Coefficient
Gas Phase Heat Transfer Coefficient is the heat transfer in gas per unit area in kelvin.
Symbol: hg
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value can be positive or negative.
Liquid Phase Heat Transfer Coefficient
Liquid Phase Heat Transfer Coefficient is the heat transfer in liquid per unit area in kelvin.
Symbol: h1
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value can be positive or negative.
Inside Temperature
Inside Temperature is the temperature of air present inside.
Symbol: ti
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Liquid layer temperature
Liquid layer temperature is defined as the temperature of the flowing liquid layer in dehumidification.
Symbol: Tl
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Enthalpy of Evaporation
Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas.
Symbol: hfg
Measurement: Specific EntropyUnit: J/kg*K
Note: Value can be positive or negative.
Gas Phase Mass Transfer Coefficient
Gas phase mass transfer coefficient is a diffusion rate constant that relates the mass transfer rate, mass transfer area, and concentration change as driving force.
Symbol: ky
Measurement: Molar Flux of Diffusing ComponentUnit: mol/s*m²
Note: Value can be positive or negative.
Absolute Humidity of Air(tg)
Absolute Humidity of Air(tg) at the initial air temperature.
Symbol: Yg
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Absolute Humidity (ti)
Absolute humidity (ti) is the quality of water vapor in the wet air of unit volume at temperature ti.
Symbol: Yi
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Bulk Gas Temperature
Bulk gas temperature is adiabatic mixing of the gas from a given cross section of duct will result in some equilibrium temperature that accurately reflects average temperature of the moving fluid.
Symbol: Tg
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Humidification category

​Go Enthalpy of evaporation for water in humidification
hfg=hConv(T∞-Tw)kL(Pw-P∞)
​Go Convective mass transfer coefficient in humidification
kL=hConv(T∞-Tw)hfg(Pw-P∞)

How to Evaluate Gas phase heat transfer coefficient in dehumidification?

Gas phase heat transfer coefficient in dehumidification evaluator uses Gas Phase Heat Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/(Bulk Gas Temperature-Inside Temperature) to evaluate the Gas Phase Heat Transfer Coefficient, The Gas phase heat transfer coefficient in dehumidification formula is defined as convective heat transfer relation between gas medium and surface on which the gas is flowing. Gas Phase Heat Transfer Coefficient is denoted by hg symbol.

How to evaluate Gas phase heat transfer coefficient in dehumidification using this online evaluator? To use this online evaluator for Gas phase heat transfer coefficient in dehumidification, enter Liquid Phase Heat Transfer Coefficient (h1), Inside Temperature (ti), Liquid layer temperature (Tl), Enthalpy of Evaporation (hfg), Gas Phase Mass Transfer Coefficient (ky), Absolute Humidity of Air(tg) (Yg), Absolute Humidity (ti) (Yi) & Bulk Gas Temperature (Tg) and hit the calculate button.

FAQs on Gas phase heat transfer coefficient in dehumidification

What is the formula to find Gas phase heat transfer coefficient in dehumidification?
The formula of Gas phase heat transfer coefficient in dehumidification is expressed as Gas Phase Heat Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/(Bulk Gas Temperature-Inside Temperature). Here is an example- -1001.724901 = ((10.8*(353-20))-(90*90*(16-50.7)))/(100-353).
How to calculate Gas phase heat transfer coefficient in dehumidification?
With Liquid Phase Heat Transfer Coefficient (h1), Inside Temperature (ti), Liquid layer temperature (Tl), Enthalpy of Evaporation (hfg), Gas Phase Mass Transfer Coefficient (ky), Absolute Humidity of Air(tg) (Yg), Absolute Humidity (ti) (Yi) & Bulk Gas Temperature (Tg) we can find Gas phase heat transfer coefficient in dehumidification using the formula - Gas Phase Heat Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/(Bulk Gas Temperature-Inside Temperature).
Can the Gas phase heat transfer coefficient in dehumidification be negative?
Yes, the Gas phase heat transfer coefficient in dehumidification, measured in Heat Transfer Coefficient can be negative.
Which unit is used to measure Gas phase heat transfer coefficient in dehumidification?
Gas phase heat transfer coefficient in dehumidification is usually measured using the Watt per Square Meter per Kelvin[W/m²*K] for Heat Transfer Coefficient. Watt per Square Meter per Celcius[W/m²*K], Joule per Second per Square Meter per Kelvin[W/m²*K], Kilocalorie (IT) per Hour per Square Foot per Celcius[W/m²*K] are the few other units in which Gas phase heat transfer coefficient in dehumidification can be measured.
Copied!