Front Pitch for DC Shunt Generator Formula

Fx Copy
LaTeX Copy
Front Pitch the distance between the two coil sides connected to the same commutator segment is called front pitch. Check FAQs
YF=(2SP)-1
YF - Front Pitch?S - Number of Slots?P - Number of Poles?

Front Pitch for DC Shunt Generator Example

With values
With units
Only example

Here is how the Front Pitch for DC Shunt Generator equation looks like with Values.

Here is how the Front Pitch for DC Shunt Generator equation looks like with Units.

Here is how the Front Pitch for DC Shunt Generator equation looks like.

49Edit=(2100Edit4Edit)-1
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Front Pitch for DC Shunt Generator

Front Pitch for DC Shunt Generator Solution

Follow our step by step solution on how to calculate Front Pitch for DC Shunt Generator?

FIRST Step Consider the formula
YF=(2SP)-1
Next Step Substitute values of Variables
YF=(21004)-1
Next Step Prepare to Evaluate
YF=(21004)-1
LAST Step Evaluate
YF=49

Front Pitch for DC Shunt Generator Formula Elements

Variables
Front Pitch
Front Pitch the distance between the two coil sides connected to the same commutator segment is called front pitch.
Symbol: YF
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Number of Slots
The number of slots per pole per phase determines how the winding layout is arranged. It is also disclosing information about the winding factor and its harmonics.
Symbol: S
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Number of Poles
Number of Poles is defined as the number of poles in an electrical machine for the flux generation.
Symbol: P
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Mechanical Specifications category

​Go Back Pitch for DC Shunt Generator
YB=(2SP)+1
​Go Commutator Pitch for DC Shunt Generator
YC=YB+YF2

How to Evaluate Front Pitch for DC Shunt Generator?

Front Pitch for DC Shunt Generator evaluator uses Front Pitch = ((2*Number of Slots)/Number of Poles)-1 to evaluate the Front Pitch, The Front Pitch for DC Shunt Generator formula is defined as the coil advances on the back of the armature. This advancement is measured in terms of armature conductors and is called front pitch. It is equal to the number difference of the conductor connected to a given segment of the commutator. Front Pitch is denoted by YF symbol.

How to evaluate Front Pitch for DC Shunt Generator using this online evaluator? To use this online evaluator for Front Pitch for DC Shunt Generator, enter Number of Slots (S) & Number of Poles (P) and hit the calculate button.

FAQs on Front Pitch for DC Shunt Generator

What is the formula to find Front Pitch for DC Shunt Generator?
The formula of Front Pitch for DC Shunt Generator is expressed as Front Pitch = ((2*Number of Slots)/Number of Poles)-1. Here is an example- 49 = ((2*100)/4)-1.
How to calculate Front Pitch for DC Shunt Generator?
With Number of Slots (S) & Number of Poles (P) we can find Front Pitch for DC Shunt Generator using the formula - Front Pitch = ((2*Number of Slots)/Number of Poles)-1.