Frequency of charging is the frequency at which the circuit capacitor is charged. Check FAQs
fc=ZwV
fc - Frequency of Charging?Zw - Metal Removal Rate?V - Volume of Crater?

Frequency of charging from volume crater Example

With values
With units
Only example

Here is how the Frequency of charging from volume crater equation looks like with Values.

Here is how the Frequency of charging from volume crater equation looks like with Units.

Here is how the Frequency of charging from volume crater equation looks like.

1600Edit=80Edit50000Edit
You are here -
HomeIcon Home » Category Engineering » Category Production Engineering » Category Unconventional machining processes » fx Frequency of charging from volume crater

Frequency of charging from volume crater Solution

Follow our step by step solution on how to calculate Frequency of charging from volume crater?

FIRST Step Consider the formula
fc=ZwV
Next Step Substitute values of Variables
fc=80m³/s50000mm²
Next Step Convert Units
fc=80m³/s0.05
Next Step Prepare to Evaluate
fc=800.05
Next Step Evaluate
fc=1600Hz
LAST Step Convert to Output's Unit
fc=1600cycle/s

Frequency of charging from volume crater Formula Elements

Variables
Frequency of Charging
Frequency of charging is the frequency at which the circuit capacitor is charged.
Symbol: fc
Measurement: FrequencyUnit: cycle/s
Note: Value can be positive or negative.
Metal Removal Rate
Metal removal rate (MRR) is the amount of material removed per time unit (usually per minute) when performing machining operations such as using a lathe or milling machine.
Symbol: Zw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Volume of Crater
Volume of crater is defined as the Volume of crater made by an electric spark during EDM.
Symbol: V
Measurement: AreaUnit: mm²
Note: Value should be greater than 0.

Other formulas in Material removal rate (MRR) category

​Go Material removal rate, MRR
MRR=-KmrrVc22Rcln(1-(VcV0))
​Go Proportionality constant for MRR
Kmrr=-MRR(2Rcln(1-(VcV0)))Vc2
​Go Resistance of circuit
Rc=-KmrrVc22MRRln(1-(VcV0))
​Go Input power supply to achieve given MRR
V0=Vc1-exp(-KmrrVc22RcZw)

How to Evaluate Frequency of charging from volume crater?

Frequency of charging from volume crater evaluator uses Frequency of Charging = Metal Removal Rate/Volume of Crater to evaluate the Frequency of Charging, Frequency of charging from volume crater formula is defined as the number of sparks produced per second while charging of the relaxation circuit. It is the inverse of the time period for a given oscillation. Frequency of Charging is denoted by fc symbol.

How to evaluate Frequency of charging from volume crater using this online evaluator? To use this online evaluator for Frequency of charging from volume crater, enter Metal Removal Rate (Zw) & Volume of Crater (V) and hit the calculate button.

FAQs on Frequency of charging from volume crater

What is the formula to find Frequency of charging from volume crater?
The formula of Frequency of charging from volume crater is expressed as Frequency of Charging = Metal Removal Rate/Volume of Crater. Here is an example- 800000 = 80/0.05.
How to calculate Frequency of charging from volume crater?
With Metal Removal Rate (Zw) & Volume of Crater (V) we can find Frequency of charging from volume crater using the formula - Frequency of Charging = Metal Removal Rate/Volume of Crater.
Can the Frequency of charging from volume crater be negative?
Yes, the Frequency of charging from volume crater, measured in Frequency can be negative.
Which unit is used to measure Frequency of charging from volume crater?
Frequency of charging from volume crater is usually measured using the Cycle per Second[cycle/s] for Frequency. Hertz[cycle/s], Petahertz[cycle/s], Terahertz[cycle/s] are the few other units in which Frequency of charging from volume crater can be measured.
Copied!