Frequency of 3rd Harmonic Closed Organ Pipe Formula

Fx Copy
LaTeX Copy
Frequency of 3rd Harmonic Closed Organ Pipe is the number of oscillations or cycles per second of the third harmonic sound wave produced by a closed organ pipe. Check FAQs
f3rd=34vwLclosed
f3rd - Frequency of 3rd Harmonic Closed Organ Pipe?vw - Velocity of Wave?Lclosed - Length of Closed Organ Pipe?

Frequency of 3rd Harmonic Closed Organ Pipe Example

With values
With units
Only example

Here is how the Frequency of 3rd Harmonic Closed Organ Pipe equation looks like with Values.

Here is how the Frequency of 3rd Harmonic Closed Organ Pipe equation looks like with Units.

Here is how the Frequency of 3rd Harmonic Closed Organ Pipe equation looks like.

97.5Edit=3465Edit0.5Edit
You are here -
HomeIcon Home » Category Physics » Category Basic Physics » Category Optics and Waves » fx Frequency of 3rd Harmonic Closed Organ Pipe

Frequency of 3rd Harmonic Closed Organ Pipe Solution

Follow our step by step solution on how to calculate Frequency of 3rd Harmonic Closed Organ Pipe?

FIRST Step Consider the formula
f3rd=34vwLclosed
Next Step Substitute values of Variables
f3rd=3465m/s0.5m
Next Step Prepare to Evaluate
f3rd=34650.5
LAST Step Evaluate
f3rd=97.5Hz

Frequency of 3rd Harmonic Closed Organ Pipe Formula Elements

Variables
Frequency of 3rd Harmonic Closed Organ Pipe
Frequency of 3rd Harmonic Closed Organ Pipe is the number of oscillations or cycles per second of the third harmonic sound wave produced by a closed organ pipe.
Symbol: f3rd
Measurement: FrequencyUnit: Hz
Note: Value can be positive or negative.
Velocity of Wave
Velocity of Wave is the speed at which a wave propagates through a medium, typically measured in meters per second, and is an important concept in physics and engineering.
Symbol: vw
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Length of Closed Organ Pipe
Length of Closed Organ Pipe is the distance of a pipe that is closed at one end, used to produce sound waves of specific frequencies.
Symbol: Lclosed
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Resonance in Pipes category

​Go Length of Open Organ Pipe
Lopen=n2vwf
​Go Length of Closed Organ Pipe
Lclosed=(2n+1)λ4
​Go Frequency of Closed Organ Pipe
fclosed pipe=2n+14vwLclosed
​Go Frequency of Open Organ Pipe
fopen pipe=n2vwLopen

How to Evaluate Frequency of 3rd Harmonic Closed Organ Pipe?

Frequency of 3rd Harmonic Closed Organ Pipe evaluator uses Frequency of 3rd Harmonic Closed Organ Pipe = 3/4*Velocity of Wave/Length of Closed Organ Pipe to evaluate the Frequency of 3rd Harmonic Closed Organ Pipe, Frequency of 3rd Harmonic Closed Organ Pipe formula is defined as the measure of the rate at which the third harmonic wave oscillates in a closed organ pipe, which is a musical instrument that produces sound when air is blown through it and is affected by the velocity of the wave and the length of the pipe. Frequency of 3rd Harmonic Closed Organ Pipe is denoted by f3rd symbol.

How to evaluate Frequency of 3rd Harmonic Closed Organ Pipe using this online evaluator? To use this online evaluator for Frequency of 3rd Harmonic Closed Organ Pipe, enter Velocity of Wave (vw) & Length of Closed Organ Pipe (Lclosed) and hit the calculate button.

FAQs on Frequency of 3rd Harmonic Closed Organ Pipe

What is the formula to find Frequency of 3rd Harmonic Closed Organ Pipe?
The formula of Frequency of 3rd Harmonic Closed Organ Pipe is expressed as Frequency of 3rd Harmonic Closed Organ Pipe = 3/4*Velocity of Wave/Length of Closed Organ Pipe. Here is an example- 97.5 = 3/4*65/0.5.
How to calculate Frequency of 3rd Harmonic Closed Organ Pipe?
With Velocity of Wave (vw) & Length of Closed Organ Pipe (Lclosed) we can find Frequency of 3rd Harmonic Closed Organ Pipe using the formula - Frequency of 3rd Harmonic Closed Organ Pipe = 3/4*Velocity of Wave/Length of Closed Organ Pipe.
Can the Frequency of 3rd Harmonic Closed Organ Pipe be negative?
Yes, the Frequency of 3rd Harmonic Closed Organ Pipe, measured in Frequency can be negative.
Which unit is used to measure Frequency of 3rd Harmonic Closed Organ Pipe?
Frequency of 3rd Harmonic Closed Organ Pipe is usually measured using the Hertz[Hz] for Frequency. Petahertz[Hz], Terahertz[Hz], Gigahertz[Hz] are the few other units in which Frequency of 3rd Harmonic Closed Organ Pipe can be measured.
Copied!