Slab Force at maximum positive moments. Check FAQs
Pon slab=NΦSultimate
Pon slab - Slab Force?N - No of Connector in Bridge?Φ - Reduction Factor?Sultimate - Ultimate Shear Connector Stress?

Force in Slab given Number of Connectors in Bridges Example

With values
With units
Only example

Here is how the Force in Slab given Number of Connectors in Bridges equation looks like with Values.

Here is how the Force in Slab given Number of Connectors in Bridges equation looks like with Units.

Here is how the Force in Slab given Number of Connectors in Bridges equation looks like.

255Edit=15Edit0.85Edit20Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Bridge and Suspension Cable » fx Force in Slab given Number of Connectors in Bridges

Force in Slab given Number of Connectors in Bridges Solution

Follow our step by step solution on how to calculate Force in Slab given Number of Connectors in Bridges?

FIRST Step Consider the formula
Pon slab=NΦSultimate
Next Step Substitute values of Variables
Pon slab=150.8520kN
Next Step Convert Units
Pon slab=150.8520000N
Next Step Prepare to Evaluate
Pon slab=150.8520000
Next Step Evaluate
Pon slab=255000N
LAST Step Convert to Output's Unit
Pon slab=255kN

Force in Slab given Number of Connectors in Bridges Formula Elements

Variables
Slab Force
Slab Force at maximum positive moments.
Symbol: Pon slab
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
No of Connector in Bridge
No of Connector in Bridge is total number of joints.
Symbol: N
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Reduction Factor
Reduction Factor is constant term used as factor for load calculation.
Symbol: Φ
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Ultimate Shear Connector Stress
Ultimate Shear Connector Stress is the maximum strength in shear.
Symbol: Sultimate
Measurement: ForceUnit: kN
Note: Value can be positive or negative.

Other Formulas to find Slab Force

​Go Force in Slab given Total Area of Steel Section
Pon slab=Astfy
​Go Force in Slab given Effective Concrete Area
Pon slab=0.85Aconcretefc
​Go Force in Slab at Maximum Positive Moments given Minimum Number of Connectors for Bridges
Pon slab=NΦSultimate-P3
​Go Force in Slab at Maximum Negative Moments given Reinforcing Steel Yield Strength
Pon slab=Astfy

Other formulas in Number of Connectors in Bridges category

​Go Number of Connectors in Bridges
N=Pon slabΦSultimate
​Go Reduction Factor given Number of Connectors in Bridges
Φ=Pon slabNSultimate
​Go Ultimate Shear Connector Strength given Number of Connectors in Bridges
Sultimate=Pon slabNΦ
​Go Total Area of Steel Section given Force in Slab
Ast=Pon slabfy

How to Evaluate Force in Slab given Number of Connectors in Bridges?

Force in Slab given Number of Connectors in Bridges evaluator uses Slab Force = No of Connector in Bridge*Reduction Factor*Ultimate Shear Connector Stress to evaluate the Slab Force, The Force in Slab given Number of Connectors in Bridges formula is defined as the force acting at the point of the maximum positive moment and end supports. Slab Force is denoted by Pon slab symbol.

How to evaluate Force in Slab given Number of Connectors in Bridges using this online evaluator? To use this online evaluator for Force in Slab given Number of Connectors in Bridges, enter No of Connector in Bridge (N), Reduction Factor (Φ) & Ultimate Shear Connector Stress (Sultimate) and hit the calculate button.

FAQs on Force in Slab given Number of Connectors in Bridges

What is the formula to find Force in Slab given Number of Connectors in Bridges?
The formula of Force in Slab given Number of Connectors in Bridges is expressed as Slab Force = No of Connector in Bridge*Reduction Factor*Ultimate Shear Connector Stress. Here is an example- 0.255 = 15*0.85*20000.
How to calculate Force in Slab given Number of Connectors in Bridges?
With No of Connector in Bridge (N), Reduction Factor (Φ) & Ultimate Shear Connector Stress (Sultimate) we can find Force in Slab given Number of Connectors in Bridges using the formula - Slab Force = No of Connector in Bridge*Reduction Factor*Ultimate Shear Connector Stress.
What are the other ways to Calculate Slab Force?
Here are the different ways to Calculate Slab Force-
  • Slab Force=Area of Steel Reinforcement*Yield Strength of SteelOpenImg
  • Slab Force=0.85*Effective Concrete Area*28 Day Compressive Strength of ConcreteOpenImg
  • Slab Force=No of Connector in Bridge*Reduction Factor*Ultimate Shear Connector Stress-Force in Slab at Negative Moment PointOpenImg
Can the Force in Slab given Number of Connectors in Bridges be negative?
Yes, the Force in Slab given Number of Connectors in Bridges, measured in Force can be negative.
Which unit is used to measure Force in Slab given Number of Connectors in Bridges?
Force in Slab given Number of Connectors in Bridges is usually measured using the Kilonewton[kN] for Force. Newton[kN], Exanewton[kN], Meganewton[kN] are the few other units in which Force in Slab given Number of Connectors in Bridges can be measured.
Copied!