Flux Linkage Sensitivity Formula

Fx Copy
LaTeX Copy
Flux Linkage Sensitivity is the capability of a device to react to alterations in magnetic flux linking its coils, indicating its responsiveness to changes in magnetic field strength. Check FAQs
Φ=SgRg
Φ - Flux Linkage Sensitivity?Sg - Ballistic Sensitivity?Rg - Galvanometer Circuit Resistance?

Flux Linkage Sensitivity Example

With values
With units
Only example

Here is how the Flux Linkage Sensitivity equation looks like with Values.

Here is how the Flux Linkage Sensitivity equation looks like with Units.

Here is how the Flux Linkage Sensitivity equation looks like.

0.2475Edit=2.5Edit10.1Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Flux Linkage Sensitivity

Flux Linkage Sensitivity Solution

Follow our step by step solution on how to calculate Flux Linkage Sensitivity?

FIRST Step Consider the formula
Φ=SgRg
Next Step Substitute values of Variables
Φ=2.5rad/C10.1Ω
Next Step Prepare to Evaluate
Φ=2.510.1
Next Step Evaluate
Φ=0.247524752475248
LAST Step Rounding Answer
Φ=0.2475

Flux Linkage Sensitivity Formula Elements

Variables
Flux Linkage Sensitivity
Flux Linkage Sensitivity is the capability of a device to react to alterations in magnetic flux linking its coils, indicating its responsiveness to changes in magnetic field strength.
Symbol: Φ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Ballistic Sensitivity
Ballistic Sensitivity measures a galvanometer's ability to respond quickly to transient currents, indicating its capacity to accurately measure short-duration electrical signals.
Symbol: Sg
Measurement: Ballistic SensitivityUnit: rad/C
Note: Value should be greater than 0.
Galvanometer Circuit Resistance
Galvanometer Circuit Resistance is the total resistance in a circuit containing a galvanometer, including the internal resistance of the galvanometer and any external resistance added.
Symbol: Rg
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Instrument Transformer category

​Go Voltage of Secondary Coil in Transformer Ratio Method
Vs=NsVpNp
​Go Turns Ratio in Transformer Ratio Method
η=NsNp
​Go Transformer Ratio
R=ΦpΦs
​Go Primary Phasor
Φp=RΦs

How to Evaluate Flux Linkage Sensitivity?

Flux Linkage Sensitivity evaluator uses Flux Linkage Sensitivity = Ballistic Sensitivity/Galvanometer Circuit Resistance to evaluate the Flux Linkage Sensitivity, The Flux Linkage Sensitivity formula is defined as the deflection of the galvanometer or its sensitivity during flux change. Flux Linkage Sensitivity is denoted by Φ symbol.

How to evaluate Flux Linkage Sensitivity using this online evaluator? To use this online evaluator for Flux Linkage Sensitivity, enter Ballistic Sensitivity (Sg) & Galvanometer Circuit Resistance (Rg) and hit the calculate button.

FAQs on Flux Linkage Sensitivity

What is the formula to find Flux Linkage Sensitivity?
The formula of Flux Linkage Sensitivity is expressed as Flux Linkage Sensitivity = Ballistic Sensitivity/Galvanometer Circuit Resistance. Here is an example- 0.247525 = 2.5/10.1.
How to calculate Flux Linkage Sensitivity?
With Ballistic Sensitivity (Sg) & Galvanometer Circuit Resistance (Rg) we can find Flux Linkage Sensitivity using the formula - Flux Linkage Sensitivity = Ballistic Sensitivity/Galvanometer Circuit Resistance.
Copied!