Fluoroscence Intensity without Quenching Formula

Fx Copy
LaTeX Copy
Intensity Without Quenching is the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy. Check FAQs
I_o=KfIaKNR+Kf
I_o - Intensity Without Quenching?Kf - Rate Constant of Fluoroscence?Ia - Absorption Intensity?KNR - Rate Constant of Non Radiative Reaction?

Fluoroscence Intensity without Quenching Example

With values
With units
Only example

Here is how the Fluoroscence Intensity without Quenching equation looks like with Values.

Here is how the Fluoroscence Intensity without Quenching equation looks like with Units.

Here is how the Fluoroscence Intensity without Quenching equation looks like.

238.8535Edit=750Edit250Edit35Edit+750Edit
You are here -
HomeIcon Home » Category Chemistry » Category Physical Chemistry » Category Physical spectroscopy » fx Fluoroscence Intensity without Quenching

Fluoroscence Intensity without Quenching Solution

Follow our step by step solution on how to calculate Fluoroscence Intensity without Quenching?

FIRST Step Consider the formula
I_o=KfIaKNR+Kf
Next Step Substitute values of Variables
I_o=750rev/s250W/m²35rev/s+750rev/s
Next Step Convert Units
I_o=750Hz250W/m²35Hz+750Hz
Next Step Prepare to Evaluate
I_o=75025035+750
Next Step Evaluate
I_o=238.853503184713W/m²
LAST Step Rounding Answer
I_o=238.8535W/m²

Fluoroscence Intensity without Quenching Formula Elements

Variables
Intensity Without Quenching
Intensity Without Quenching is the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy.
Symbol: I_o
Measurement: IntensityUnit: W/m²
Note: Value can be positive or negative.
Rate Constant of Fluoroscence
Rate Constant of Fluoroscence is the rate at which spontaneous emission occurs.
Symbol: Kf
Measurement: FrequencyUnit: rev/s
Note: Value can be positive or negative.
Absorption Intensity
Absorption Intensity obtained by integrating the area under the absorption line—is proportional to the amount of the absorbing substance present.
Symbol: Ia
Measurement: IntensityUnit: W/m²
Note: Value can be positive or negative.
Rate Constant of Non Radiative Reaction
Rate Constant of Non Radiative Reaction is defined as the rate at which deactivation occurs in the form of heat energy.
Symbol: KNR
Measurement: FrequencyUnit: rev/s
Note: Value can be positive or negative.

Other formulas in Emission Spectroscopy category

​Go Fluorescence Rate Constant
Kf=Rf[MS1]
​Go Fluoroscence Intensity
IF=KfIaKf+KNR
​Go Initial Intensity given Degree of Exciplex Formation
Ioα=KfKeqKf+KNR
​Go Intensity of Fluorescence given Degree of Exciplex Formation
Ifgiven_α=KfKeq1-αKf+KNR

How to Evaluate Fluoroscence Intensity without Quenching?

Fluoroscence Intensity without Quenching evaluator uses Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence) to evaluate the Intensity Without Quenching, The Fluoroscence Intensity without Quenching formula is defined as the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy. Intensity Without Quenching is denoted by I_o symbol.

How to evaluate Fluoroscence Intensity without Quenching using this online evaluator? To use this online evaluator for Fluoroscence Intensity without Quenching, enter Rate Constant of Fluoroscence (Kf), Absorption Intensity (Ia) & Rate Constant of Non Radiative Reaction (KNR) and hit the calculate button.

FAQs on Fluoroscence Intensity without Quenching

What is the formula to find Fluoroscence Intensity without Quenching?
The formula of Fluoroscence Intensity without Quenching is expressed as Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence). Here is an example- 238.8535 = (750*250)/(35+750).
How to calculate Fluoroscence Intensity without Quenching?
With Rate Constant of Fluoroscence (Kf), Absorption Intensity (Ia) & Rate Constant of Non Radiative Reaction (KNR) we can find Fluoroscence Intensity without Quenching using the formula - Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence).
Can the Fluoroscence Intensity without Quenching be negative?
Yes, the Fluoroscence Intensity without Quenching, measured in Intensity can be negative.
Which unit is used to measure Fluoroscence Intensity without Quenching?
Fluoroscence Intensity without Quenching is usually measured using the Watt per Square Meter[W/m²] for Intensity. Watt per Square Centimeter[W/m²], Watt per Square Millimeter[W/m²], Kilowatt per Square Meter[W/m²] are the few other units in which Fluoroscence Intensity without Quenching can be measured.
Copied!