Fx Copy
LaTeX Copy
Oil film thickness is defined as the thickness of the oil film between the two parts in relative motion. Check FAQs
h=(l12μlQslotbΔP)13
h - Oil film thickness?l - Length of slot in direction of flow?μl - Dynamic Viscosity of Lubricant?Qslot - Flow of lubricant from slot?b - Breadth of slot for oil flow?ΔP - Pressure difference between slot sides?

Fluid Film Thickness in Terms of Flow of Lubricant Example

With values
With units
Only example

Here is how the Fluid Film Thickness in Terms of Flow of Lubricant equation looks like with Values.

Here is how the Fluid Film Thickness in Terms of Flow of Lubricant equation looks like with Units.

Here is how the Fluid Film Thickness in Terms of Flow of Lubricant equation looks like.

0.0197Edit=(48Edit12220Edit15Edit49Edit5.1Edit)13
You are here -
HomeIcon Home » Category Engineering » Category Mechanical » Category Machine Design » fx Fluid Film Thickness in Terms of Flow of Lubricant

Fluid Film Thickness in Terms of Flow of Lubricant Solution

Follow our step by step solution on how to calculate Fluid Film Thickness in Terms of Flow of Lubricant?

FIRST Step Consider the formula
h=(l12μlQslotbΔP)13
Next Step Substitute values of Variables
h=(48mm12220cP15mm³/s49mm5.1MPa)13
Next Step Convert Units
h=(0.048m120.22Pa*s1.5E-8m³/s0.049m5.1E+6Pa)13
Next Step Prepare to Evaluate
h=(0.048120.221.5E-80.0495.1E+6)13
Next Step Evaluate
h=1.96663330218532E-05m
Next Step Convert to Output's Unit
h=0.0196663330218532mm
LAST Step Rounding Answer
h=0.0197mm

Fluid Film Thickness in Terms of Flow of Lubricant Formula Elements

Variables
Oil film thickness
Oil film thickness is defined as the thickness of the oil film between the two parts in relative motion.
Symbol: h
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Length of slot in direction of flow
Length of slot in direction of flow is the length of the rectangular slot through which viscous oil flows.
Symbol: l
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Dynamic Viscosity of Lubricant
The Dynamic Viscosity of Lubricant is the resistance to movement of one layer of fluid over another.
Symbol: μl
Measurement: Dynamic ViscosityUnit: cP
Note: Value should be greater than 0.
Flow of lubricant from slot
Flow of lubricant from slot can be defined as the amount of lubricant flowing per unit time between the slots.
Symbol: Qslot
Measurement: Volumetric Flow RateUnit: mm³/s
Note: Value should be greater than 0.
Breadth of slot for oil flow
Breadth of slot for oil flow is defined as the length of the rectangular slot in a plane perpendicular to the direction of flow.
Symbol: b
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Pressure difference between slot sides
Pressure difference between slot sides is the difference in pressure intensities at two different sides of the slot.
Symbol: ΔP
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.

Other Formulas to find Oil film thickness

​Go Film Thickness in Terms of Absolute Viscosity and Tangential Force
h=μoApoVmP
​Go Film Thickness in Terms of Flow Coefficient and Flow of Lubricant
h=(QApμlWqf)13

Other formulas in Film Thickness category

​Go Minimum Film Thickness given Radius of Bearing
h°=R-(e+r)
​Go Eccentricity of Bearing in Terms of Minimum Film Thickness
e=R-(h°+r)
​Go Minimum Film Thickness Variable of Bearing
hmin=h°c
​Go Minimum Film Thickness in Terms of Minimum Film Thickness Variable of Bearing
h°=hminc

How to Evaluate Fluid Film Thickness in Terms of Flow of Lubricant?

Fluid Film Thickness in Terms of Flow of Lubricant evaluator uses Oil film thickness = (Length of slot in direction of flow*12*Dynamic Viscosity of Lubricant*Flow of lubricant from slot/(Breadth of slot for oil flow*Pressure difference between slot sides))^(1/3) to evaluate the Oil film thickness, The Fluid Film Thickness in Terms of Flow of Lubricant formula is defined as one-third of the power of the ratio product of 12 times the value of length of the slot, viscosity of the lubricant, and flow of lubricant to the product of dimension b and pressure difference. Oil film thickness is denoted by h symbol.

How to evaluate Fluid Film Thickness in Terms of Flow of Lubricant using this online evaluator? To use this online evaluator for Fluid Film Thickness in Terms of Flow of Lubricant, enter Length of slot in direction of flow (l), Dynamic Viscosity of Lubricant l), Flow of lubricant from slot (Qslot), Breadth of slot for oil flow (b) & Pressure difference between slot sides (ΔP) and hit the calculate button.

FAQs on Fluid Film Thickness in Terms of Flow of Lubricant

What is the formula to find Fluid Film Thickness in Terms of Flow of Lubricant?
The formula of Fluid Film Thickness in Terms of Flow of Lubricant is expressed as Oil film thickness = (Length of slot in direction of flow*12*Dynamic Viscosity of Lubricant*Flow of lubricant from slot/(Breadth of slot for oil flow*Pressure difference between slot sides))^(1/3). Here is an example- 19.66633 = (0.048*12*0.22*1.5E-08/(0.049*5100000))^(1/3).
How to calculate Fluid Film Thickness in Terms of Flow of Lubricant?
With Length of slot in direction of flow (l), Dynamic Viscosity of Lubricant l), Flow of lubricant from slot (Qslot), Breadth of slot for oil flow (b) & Pressure difference between slot sides (ΔP) we can find Fluid Film Thickness in Terms of Flow of Lubricant using the formula - Oil film thickness = (Length of slot in direction of flow*12*Dynamic Viscosity of Lubricant*Flow of lubricant from slot/(Breadth of slot for oil flow*Pressure difference between slot sides))^(1/3).
What are the other ways to Calculate Oil film thickness?
Here are the different ways to Calculate Oil film thickness-
  • Oil film thickness=Dynamic viscosity of oil*Area of moving plate on oil*Velocity of Moving Plate on Oil/Tangential force on moving plateOpenImg
  • Oil film thickness=(Flow of Lubricant*Total Projected Area of Bearing Pad*Dynamic Viscosity of Lubricant/(Load Acting on Sliding Bearing*Flow Coefficient))^(1/3)OpenImg
Can the Fluid Film Thickness in Terms of Flow of Lubricant be negative?
No, the Fluid Film Thickness in Terms of Flow of Lubricant, measured in Length cannot be negative.
Which unit is used to measure Fluid Film Thickness in Terms of Flow of Lubricant?
Fluid Film Thickness in Terms of Flow of Lubricant is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Fluid Film Thickness in Terms of Flow of Lubricant can be measured.
Copied!