Flow velocity at outlet of centrifugal pump is the velocity of the fluid at the outlet of the impeller or the centrifugal pump. Check FAQs
Vf2=QπD2B2
Vf2 - Flow Velocity at Outlet of Centrifugal Pump?Q - Actual Discharge at Centrifugal Pump Outlet?D2 - Diameter of Centrifugal Pump Impeller at Outlet?B2 - Width of Impeller at Outlet?π - Archimedes' constant?

Flow velocity at outlet given volume of liquid Example

With values
With units
Only example

Here is how the Flow velocity at outlet given volume of liquid equation looks like with Values.

Here is how the Flow velocity at outlet given volume of liquid equation looks like with Units.

Here is how the Flow velocity at outlet given volume of liquid equation looks like.

2.1221Edit=0.056Edit3.14160.28Edit0.03Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Flow velocity at outlet given volume of liquid

Flow velocity at outlet given volume of liquid Solution

Follow our step by step solution on how to calculate Flow velocity at outlet given volume of liquid?

FIRST Step Consider the formula
Vf2=QπD2B2
Next Step Substitute values of Variables
Vf2=0.056m³/sπ0.28m0.03m
Next Step Substitute values of Constants
Vf2=0.056m³/s3.14160.28m0.03m
Next Step Prepare to Evaluate
Vf2=0.0563.14160.280.03
Next Step Evaluate
Vf2=2.12206590789194m/s
LAST Step Rounding Answer
Vf2=2.1221m/s

Flow velocity at outlet given volume of liquid Formula Elements

Variables
Constants
Flow Velocity at Outlet of Centrifugal Pump
Flow velocity at outlet of centrifugal pump is the velocity of the fluid at the outlet of the impeller or the centrifugal pump.
Symbol: Vf2
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Actual Discharge at Centrifugal Pump Outlet
Actual discharge at centrifugal pump outlet is the actual amount of the liquid outflow from the outlet of the centrifugal pump.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Diameter of Centrifugal Pump Impeller at Outlet
Diameter of centrifugal pump impeller at outlet is the diameter of the impeller at the outlet of the centrifugal pump.
Symbol: D2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Width of Impeller at Outlet
The Width of Impeller at Outlet is the width of the impeller at the outlet of the pump.
Symbol: B2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other Formulas to find Flow Velocity at Outlet of Centrifugal Pump

​Go Flow velocity given flow ratio
Vf2=Kf2[g]Hm

Other formulas in Geometric and Flow Parameters category

​Go Speed ratio
Ku=u22[g]Hm
​Go Volume of liquid at inlet
Q=πD1B1Vf1
​Go Weight of liquid
Wl=yQ
​Go Static head
Hst=hs+hd

How to Evaluate Flow velocity at outlet given volume of liquid?

Flow velocity at outlet given volume of liquid evaluator uses Flow Velocity at Outlet of Centrifugal Pump = Actual Discharge at Centrifugal Pump Outlet/(pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet) to evaluate the Flow Velocity at Outlet of Centrifugal Pump, Flow velocity at outlet given volume of liquid formula is defined as the rate at which a liquid flows out of a centrifugal pump, influenced by the pump's geometric and flow parameters, providing valuable insights into the pump's performance and efficiency. Flow Velocity at Outlet of Centrifugal Pump is denoted by Vf2 symbol.

How to evaluate Flow velocity at outlet given volume of liquid using this online evaluator? To use this online evaluator for Flow velocity at outlet given volume of liquid, enter Actual Discharge at Centrifugal Pump Outlet (Q), Diameter of Centrifugal Pump Impeller at Outlet (D2) & Width of Impeller at Outlet (B2) and hit the calculate button.

FAQs on Flow velocity at outlet given volume of liquid

What is the formula to find Flow velocity at outlet given volume of liquid?
The formula of Flow velocity at outlet given volume of liquid is expressed as Flow Velocity at Outlet of Centrifugal Pump = Actual Discharge at Centrifugal Pump Outlet/(pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet). Here is an example- 2.122066 = 0.056/(pi*0.28*0.03).
How to calculate Flow velocity at outlet given volume of liquid?
With Actual Discharge at Centrifugal Pump Outlet (Q), Diameter of Centrifugal Pump Impeller at Outlet (D2) & Width of Impeller at Outlet (B2) we can find Flow velocity at outlet given volume of liquid using the formula - Flow Velocity at Outlet of Centrifugal Pump = Actual Discharge at Centrifugal Pump Outlet/(pi*Diameter of Centrifugal Pump Impeller at Outlet*Width of Impeller at Outlet). This formula also uses Archimedes' constant .
What are the other ways to Calculate Flow Velocity at Outlet of Centrifugal Pump?
Here are the different ways to Calculate Flow Velocity at Outlet of Centrifugal Pump-
  • Flow Velocity at Outlet of Centrifugal Pump=Flow Ratio Centrifugal Pump*sqrt(2*[g]*Manometric Head of Centrifugal Pump)OpenImg
Can the Flow velocity at outlet given volume of liquid be negative?
No, the Flow velocity at outlet given volume of liquid, measured in Speed cannot be negative.
Which unit is used to measure Flow velocity at outlet given volume of liquid?
Flow velocity at outlet given volume of liquid is usually measured using the Meter per Second[m/s] for Speed. Meter per Minute[m/s], Meter per Hour[m/s], Kilometer per Hour[m/s] are the few other units in which Flow velocity at outlet given volume of liquid can be measured.
Copied!