Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula Formula

Fx Copy
LaTeX Copy
Flood Discharge by Nawab J Bahadur Formula for FPS refers to the volume of water flowing through a river or stream during a flood event, typically measured in cfs. Check FAQs
QNF=CNF(A1)0.92-(114)log10(A1)
QNF - Flood Discharge by Nawab J Bahadur Formula for FPS?CNF - Nawab Jang Bahadur Constant for FPS?A1 - Area of Basin?

Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula Example

With values
With units
Only example

Here is how the Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula equation looks like with Values.

Here is how the Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula equation looks like with Units.

Here is how the Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula equation looks like.

3746.2237Edit=1600Edit(2.6Edit)0.92-(114)log10(2.6Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula

Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula Solution

Follow our step by step solution on how to calculate Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula?

FIRST Step Consider the formula
QNF=CNF(A1)0.92-(114)log10(A1)
Next Step Substitute values of Variables
QNF=1600(2.6mi²)0.92-(114)log10(2.6mi²)
Next Step Convert Units
QNF=1600(2.6mi²)0.92-(114)log10(2.6mi²)
Next Step Prepare to Evaluate
QNF=1600(2.6)0.92-(114)log10(2.6)
Next Step Evaluate
QNF=106.081240663932m³/s
Next Step Convert to Output's Unit
QNF=3746.22365940382ft³/s
LAST Step Rounding Answer
QNF=3746.2237ft³/s

Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula Formula Elements

Variables
Functions
Flood Discharge by Nawab J Bahadur Formula for FPS
Flood Discharge by Nawab J Bahadur Formula for FPS refers to the volume of water flowing through a river or stream during a flood event, typically measured in cfs.
Symbol: QNF
Measurement: Volumetric Flow RateUnit: ft³/s
Note: Value should be greater than 0.
Nawab Jang Bahadur Constant for FPS
Nawab Jang Bahadur Constant for FPS refers to an empirical coefficient used in hydrological formulas to estimate peak flood discharge, specific to certain regions in India.
Symbol: CNF
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Area of Basin
Area of Basin refers to the surface area of a drainage basin or watershed, crucial for hydrological and flood analysis.
Symbol: A1
Measurement: AreaUnit: mi²
Note: Value should be greater than 0.
log10
The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function.
Syntax: log10(Number)

Other formulas in Nawab Jang Bahadur Formula category

​Go Flood Discharge by Nawab Jang Bahadur Formula
QN=CN(Akm)0.993-(114)log10(Akm)
​Go Constant used in Flood Discharge by Nawab Jang Bahadur Formula
CN=QN(Akm)0.993-(114)log10(Akm)
​Go Constant used in FPS Unit given Flood Discharge by Nawab Jang Bahadur Formula
CNF=(QNF(A1)0.92-(114)log10(A1))

How to Evaluate Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula?

Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula evaluator uses Flood Discharge by Nawab J Bahadur Formula for FPS = Nawab Jang Bahadur Constant for FPS*(Area of Basin)^(0.92-(1/14)*log10(Area of Basin)) to evaluate the Flood Discharge by Nawab J Bahadur Formula for FPS, The Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula is defined as the volume of water flowing through a river or stream during a flood event, typically measured in cfs. Flood Discharge by Nawab J Bahadur Formula for FPS is denoted by QNF symbol.

How to evaluate Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula using this online evaluator? To use this online evaluator for Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula, enter Nawab Jang Bahadur Constant for FPS (CNF) & Area of Basin (A1) and hit the calculate button.

FAQs on Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula

What is the formula to find Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula?
The formula of Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula is expressed as Flood Discharge by Nawab J Bahadur Formula for FPS = Nawab Jang Bahadur Constant for FPS*(Area of Basin)^(0.92-(1/14)*log10(Area of Basin)). Here is an example- 132296.6 = 1600*(6733969.0868736)^(0.92-(1/14)*log10(6733969.0868736)).
How to calculate Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula?
With Nawab Jang Bahadur Constant for FPS (CNF) & Area of Basin (A1) we can find Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula using the formula - Flood Discharge by Nawab J Bahadur Formula for FPS = Nawab Jang Bahadur Constant for FPS*(Area of Basin)^(0.92-(1/14)*log10(Area of Basin)). This formula also uses Common Logarithm (log10) function(s).
Can the Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula be negative?
No, the Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula?
Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula is usually measured using the Cubic Foot per Second[ft³/s] for Volumetric Flow Rate. Cubic Meter per Second[ft³/s], Cubic Meter per Day[ft³/s], Cubic Meter per Hour[ft³/s] are the few other units in which Flood Discharge in FPS Unit by Nawab Jang Bahadur Formula can be measured.
Copied!