Fire Duration given Reserve Storage Formula

Fx Copy
LaTeX Copy
Duration of Fire refers to the length of time that a fire burns within a given area or ecosystem. Check FAQs
t=VRF-P
t - Duration of Fire?VR - Reserve Storage?F - Fire Demand?P - Capacity of Pump?

Fire Duration given Reserve Storage Example

With values
With units
Only example

Here is how the Fire Duration given Reserve Storage equation looks like with Values.

Here is how the Fire Duration given Reserve Storage equation looks like with Units.

Here is how the Fire Duration given Reserve Storage equation looks like.

2Edit=1960Edit1100Edit-120Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Fire Duration given Reserve Storage

Fire Duration given Reserve Storage Solution

Follow our step by step solution on how to calculate Fire Duration given Reserve Storage?

FIRST Step Consider the formula
t=VRF-P
Next Step Substitute values of Variables
t=1960L1100L/d-120L/d
Next Step Convert Units
t=1.961.3E-5m³/s-1.4E-6m³/s
Next Step Prepare to Evaluate
t=1.961.3E-5-1.4E-6
Next Step Evaluate
t=172800s
LAST Step Convert to Output's Unit
t=2d

Fire Duration given Reserve Storage Formula Elements

Variables
Duration of Fire
Duration of Fire refers to the length of time that a fire burns within a given area or ecosystem.
Symbol: t
Measurement: TimeUnit: d
Note: Value can be positive or negative.
Reserve Storage
Reserve Storage refers to the capacity within a system, such as a reservoir or a water treatment facility, that is intentionally left unused or untapped under normal operating conditions.
Symbol: VR
Measurement: VolumeUnit: L
Note: Value should be greater than 0.
Fire Demand
Fire Demand is the amount of water required to extinguish fire.
Symbol: F
Measurement: Volumetric Flow RateUnit: L/d
Note: Value should be greater than 0.
Capacity of Pump
Capacity of Pump refers to the volume of fluid (such as water, sewage, or other liquids) that the pump is capable of moving within a given amount of time.
Symbol: P
Measurement: Volumetric Flow RateUnit: L/d
Note: Value should be greater than 0.

Other formulas in Capacity of Distribution Reservoir category

​Go Reserve Storage
VR=(F-P)t
​Go Fire Demand given Reserve Storage
F=(VRt)+P
​Go Reserve Fire Pumping Capacity given Reserve Storage
P=F-(VRt)
​Go Total Storage Capacity of Reservoir
T=(a+b+(1024))D+(1024)(F-P)

How to Evaluate Fire Duration given Reserve Storage?

Fire Duration given Reserve Storage evaluator uses Duration of Fire = Reserve Storage/(Fire Demand-Capacity of Pump) to evaluate the Duration of Fire, The Fire Duration given Reserve Storage is defined as the length of time a fire can be sustained given a certain amount of reserve storage, when we have prior information of other parameters used. Duration of Fire is denoted by t symbol.

How to evaluate Fire Duration given Reserve Storage using this online evaluator? To use this online evaluator for Fire Duration given Reserve Storage, enter Reserve Storage (VR), Fire Demand (F) & Capacity of Pump (P) and hit the calculate button.

FAQs on Fire Duration given Reserve Storage

What is the formula to find Fire Duration given Reserve Storage?
The formula of Fire Duration given Reserve Storage is expressed as Duration of Fire = Reserve Storage/(Fire Demand-Capacity of Pump). Here is an example- 2.3E-5 = 1.96/(1.27314814814815E-05-1.38888888888889E-06).
How to calculate Fire Duration given Reserve Storage?
With Reserve Storage (VR), Fire Demand (F) & Capacity of Pump (P) we can find Fire Duration given Reserve Storage using the formula - Duration of Fire = Reserve Storage/(Fire Demand-Capacity of Pump).
Can the Fire Duration given Reserve Storage be negative?
Yes, the Fire Duration given Reserve Storage, measured in Time can be negative.
Which unit is used to measure Fire Duration given Reserve Storage?
Fire Duration given Reserve Storage is usually measured using the Day[d] for Time. Second[d], Millisecond[d], Microsecond[d] are the few other units in which Fire Duration given Reserve Storage can be measured.
Copied!