Fx Copy
LaTeX Copy
Fire Demand is the amount of water required to extinguish fire. Check FAQs
F=(VRt)+P
F - Fire Demand?VR - Reserve Storage?t - Duration of Fire?P - Capacity of Pump?

Fire Demand given Reserve Storage Example

With values
With units
Only example

Here is how the Fire Demand given Reserve Storage equation looks like with Values.

Here is how the Fire Demand given Reserve Storage equation looks like with Units.

Here is how the Fire Demand given Reserve Storage equation looks like.

1100Edit=(1960Edit2Edit)+120Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Fire Demand given Reserve Storage

Fire Demand given Reserve Storage Solution

Follow our step by step solution on how to calculate Fire Demand given Reserve Storage?

FIRST Step Consider the formula
F=(VRt)+P
Next Step Substitute values of Variables
F=(1960L2d)+120L/d
Next Step Convert Units
F=(1.96172800s)+1.4E-6m³/s
Next Step Prepare to Evaluate
F=(1.96172800)+1.4E-6
Next Step Evaluate
F=1.27314814814815E-05m³/s
LAST Step Convert to Output's Unit
F=1100L/d

Fire Demand given Reserve Storage Formula Elements

Variables
Fire Demand
Fire Demand is the amount of water required to extinguish fire.
Symbol: F
Measurement: Volumetric Flow RateUnit: L/d
Note: Value should be greater than 0.
Reserve Storage
Reserve Storage refers to the capacity within a system, such as a reservoir or a water treatment facility, that is intentionally left unused or untapped under normal operating conditions.
Symbol: VR
Measurement: VolumeUnit: L
Note: Value should be greater than 0.
Duration of Fire
Duration of Fire refers to the length of time that a fire burns within a given area or ecosystem.
Symbol: t
Measurement: TimeUnit: d
Note: Value can be positive or negative.
Capacity of Pump
Capacity of Pump refers to the volume of fluid (such as water, sewage, or other liquids) that the pump is capable of moving within a given amount of time.
Symbol: P
Measurement: Volumetric Flow RateUnit: L/d
Note: Value should be greater than 0.

Other Formulas to find Fire Demand

​Go Fire Demand given Total Storage Capacity
F=T-((a+b+(1024))D)+((1024)P)1024
​Go Fire Demand given Value of McDonald Coefficient
F=T-((0.2+0.1+(1024))D)+((1024)P)1024

Other formulas in Capacity of Distribution Reservoir category

​Go Reserve Storage
VR=(F-P)t
​Go Reserve Fire Pumping Capacity given Reserve Storage
P=F-(VRt)
​Go Fire Duration given Reserve Storage
t=VRF-P
​Go Total Storage Capacity of Reservoir
T=(a+b+(1024))D+(1024)(F-P)

How to Evaluate Fire Demand given Reserve Storage?

Fire Demand given Reserve Storage evaluator uses Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump to evaluate the Fire Demand, The Fire Demand given Reserve Storage is defined as the amount of water required to extinguish a fire in a particular area, when we have information of reserve storage. Fire Demand is denoted by F symbol.

How to evaluate Fire Demand given Reserve Storage using this online evaluator? To use this online evaluator for Fire Demand given Reserve Storage, enter Reserve Storage (VR), Duration of Fire (t) & Capacity of Pump (P) and hit the calculate button.

FAQs on Fire Demand given Reserve Storage

What is the formula to find Fire Demand given Reserve Storage?
The formula of Fire Demand given Reserve Storage is expressed as Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump. Here is an example- 9.5E+10 = (1.96/172800)+1.38888888888889E-06.
How to calculate Fire Demand given Reserve Storage?
With Reserve Storage (VR), Duration of Fire (t) & Capacity of Pump (P) we can find Fire Demand given Reserve Storage using the formula - Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump.
What are the other ways to Calculate Fire Demand?
Here are the different ways to Calculate Fire Demand-
  • Fire Demand=(Total Storage Capacity-((Numerical Coefficient a+Numerical Coefficient b+(10/24))*Average Domestic Demand)+((10/24)*Capacity of Pump))/(10/24)OpenImg
  • Fire Demand=(Total Storage Capacity-((0.2+0.1+(10/24))*Average Domestic Demand)+((10/24)*Capacity of Pump))/(10/24)OpenImg
Can the Fire Demand given Reserve Storage be negative?
No, the Fire Demand given Reserve Storage, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Fire Demand given Reserve Storage?
Fire Demand given Reserve Storage is usually measured using the Liter per day[L/d] for Volumetric Flow Rate. Cubic Meter per Second[L/d], Cubic Meter per Day[L/d], Cubic Meter per Hour[L/d] are the few other units in which Fire Demand given Reserve Storage can be measured.
Copied!