Fire Demand for Cities of Less than 200,000 Population Formula

Fx Copy
LaTeX Copy
Fire Demand refers to the amount of water required by firefighters to extinguish fires in buildings, structures, or open areas. Check FAQs
q=1020P0.5(1-0.01(P0.5))
q - Fire Demand?P - Population in Thousands?

Fire Demand for Cities of Less than 200,000 Population Example

With values
With units
Only example

Here is how the Fire Demand for Cities of Less than 200,000 Population equation looks like with Values.

Here is how the Fire Demand for Cities of Less than 200,000 Population equation looks like with Units.

Here is how the Fire Demand for Cities of Less than 200,000 Population equation looks like.

10962.3977Edit=1020150Edit0.5(1-0.01(150Edit0.5))
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Fire Demand for Cities of Less than 200,000 Population

Fire Demand for Cities of Less than 200,000 Population Solution

Follow our step by step solution on how to calculate Fire Demand for Cities of Less than 200,000 Population?

FIRST Step Consider the formula
q=1020P0.5(1-0.01(P0.5))
Next Step Substitute values of Variables
q=10201500.5(1-0.01(1500.5))
Next Step Prepare to Evaluate
q=10201500.5(1-0.01(1500.5))
Next Step Evaluate
q=0.18270662813657m³/s
Next Step Convert to Output's Unit
q=10962.3976881942L/min
LAST Step Rounding Answer
q=10962.3977L/min

Fire Demand for Cities of Less than 200,000 Population Formula Elements

Variables
Fire Demand
Fire Demand refers to the amount of water required by firefighters to extinguish fires in buildings, structures, or open areas.
Symbol: q
Measurement: Volumetric Flow RateUnit: L/min
Note: Value should be greater than 0.
Population in Thousands
Population in Thousands refers to a demographic representation where the reported number corresponds to actual population multiplied by a factor of one thousand for ease of presentation and analysis.
Symbol: P
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Sanitary System Sewer Design category

​Go Flow Rate through Pipe using Manning Formula
W=Cf(i)12
​Go Manning's Formula for Conveyance Factor given Flow Rate through Pipe
Cf=Wi
​Go Manning's Formula for Pipe Slope given Flow Rate through Pipe
i=(WCf)2
​Go Sanitary Sewer System Flow Rate
SSfr=APdQ

How to Evaluate Fire Demand for Cities of Less than 200,000 Population?

Fire Demand for Cities of Less than 200,000 Population evaluator uses Fire Demand = 1020*Population in Thousands^0.5*(1-0.01*(Population in Thousands^0.5)) to evaluate the Fire Demand, The Fire Demand for Cities of Less than 200,000 Population formula is defined as the amount of water required to fight fires effectively. This demand is critical for urban planning and the design of water distribution systems. Fire Demand is denoted by q symbol.

How to evaluate Fire Demand for Cities of Less than 200,000 Population using this online evaluator? To use this online evaluator for Fire Demand for Cities of Less than 200,000 Population, enter Population in Thousands (P) and hit the calculate button.

FAQs on Fire Demand for Cities of Less than 200,000 Population

What is the formula to find Fire Demand for Cities of Less than 200,000 Population?
The formula of Fire Demand for Cities of Less than 200,000 Population is expressed as Fire Demand = 1020*Population in Thousands^0.5*(1-0.01*(Population in Thousands^0.5)). Here is an example- 6.6E+8 = 1020*150^0.5*(1-0.01*(150^0.5)).
How to calculate Fire Demand for Cities of Less than 200,000 Population?
With Population in Thousands (P) we can find Fire Demand for Cities of Less than 200,000 Population using the formula - Fire Demand = 1020*Population in Thousands^0.5*(1-0.01*(Population in Thousands^0.5)).
Can the Fire Demand for Cities of Less than 200,000 Population be negative?
No, the Fire Demand for Cities of Less than 200,000 Population, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Fire Demand for Cities of Less than 200,000 Population?
Fire Demand for Cities of Less than 200,000 Population is usually measured using the Liter per minute[L/min] for Volumetric Flow Rate. Cubic Meter per Second[L/min], Cubic Meter per Day[L/min], Cubic Meter per Hour[L/min] are the few other units in which Fire Demand for Cities of Less than 200,000 Population can be measured.
Copied!