Final Voltage of Schmitt Trigger Formula

Fx Copy
LaTeX Copy
Final Voltage is the voltage at the output of a circuit. Check FAQs
Vfi=Av(V+-V-)
Vfi - Final Voltage?Av - Open Loop Gain?V+ - Non-Inverting Input Voltage?V- - Inverting Input Voltage?

Final Voltage of Schmitt Trigger Example

With values
With units
Only example

Here is how the Final Voltage of Schmitt Trigger equation looks like with Values.

Here is how the Final Voltage of Schmitt Trigger equation looks like with Units.

Here is how the Final Voltage of Schmitt Trigger equation looks like.

1.0397Edit=-1.677Edit(0.97Edit-1.59Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Integrated Circuits (IC) » fx Final Voltage of Schmitt Trigger

Final Voltage of Schmitt Trigger Solution

Follow our step by step solution on how to calculate Final Voltage of Schmitt Trigger?

FIRST Step Consider the formula
Vfi=Av(V+-V-)
Next Step Substitute values of Variables
Vfi=-1.677(0.97V-1.59V)
Next Step Prepare to Evaluate
Vfi=-1.677(0.97-1.59)
Next Step Evaluate
Vfi=1.03974V
LAST Step Rounding Answer
Vfi=1.0397V

Final Voltage of Schmitt Trigger Formula Elements

Variables
Final Voltage
Final Voltage is the voltage at the output of a circuit.
Symbol: Vfi
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Open Loop Gain
The Open Loop Gain of an electronic amplifier is the gain obtained when no overall feedback is used in the circuit. It is typically measured in decibels (dB).
Symbol: Av
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Non-Inverting Input Voltage
The Non-Inverting Input Voltage of an operational amplifier (op amp) is the voltage that is applied to the pin marked with a plus (+) sign.
Symbol: V+
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Inverting Input Voltage
The Inverting Input Voltage of an operational amplifier (op amp) is the voltage that is applied to the pin marked with a minus (-) sign.
Symbol: V-
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in Schmitt Trigger category

​Go Input Current of Schmitt Trigger
in=VinRin
​Go Lower Threshold Voltage of Inverting Schmitt Trigger
Vf=-Vsat(R2R1+R2)
​Go Open Loop Gain of Schmitt Trigger
Av=VfiV+-V-
​Go Lower Threshold Voltage of Non Inverting Schmitt Trigger
Vlt=-Vsat(R2R1)

How to Evaluate Final Voltage of Schmitt Trigger?

Final Voltage of Schmitt Trigger evaluator uses Final Voltage = Open Loop Gain*(Non-Inverting Input Voltage-Inverting Input Voltage) to evaluate the Final Voltage, Final Voltage of Schmitt Trigger is determined by its input voltage levels, exhibiting hysteresis, producing a digital output based on threshold values, maintaining a stable state within a specified range. Final Voltage is denoted by Vfi symbol.

How to evaluate Final Voltage of Schmitt Trigger using this online evaluator? To use this online evaluator for Final Voltage of Schmitt Trigger, enter Open Loop Gain (Av), Non-Inverting Input Voltage (V+) & Inverting Input Voltage (V-) and hit the calculate button.

FAQs on Final Voltage of Schmitt Trigger

What is the formula to find Final Voltage of Schmitt Trigger?
The formula of Final Voltage of Schmitt Trigger is expressed as Final Voltage = Open Loop Gain*(Non-Inverting Input Voltage-Inverting Input Voltage). Here is an example- -1.03974 = (-1.677)*(0.97-1.59).
How to calculate Final Voltage of Schmitt Trigger?
With Open Loop Gain (Av), Non-Inverting Input Voltage (V+) & Inverting Input Voltage (V-) we can find Final Voltage of Schmitt Trigger using the formula - Final Voltage = Open Loop Gain*(Non-Inverting Input Voltage-Inverting Input Voltage).
Can the Final Voltage of Schmitt Trigger be negative?
Yes, the Final Voltage of Schmitt Trigger, measured in Electric Potential can be negative.
Which unit is used to measure Final Voltage of Schmitt Trigger?
Final Voltage of Schmitt Trigger is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Final Voltage of Schmitt Trigger can be measured.
Copied!