Final Efficiency after Two Stage Filtration Formula

Fx Copy
LaTeX Copy
Efficiency of second filter stage is the total efficiency obtained from the second trickling filter. Check FAQs
E2=(1001+(0.00441-E1)Y'VTF)
E2 - Efficiency of Second Filter Stage?E1 - Efficiency of First Filter Stage?Y' - BOD in Effluent?VT - Volume?F - Recirculation Factor?

Final Efficiency after Two Stage Filtration Example

With values
With units
Only example

Here is how the Final Efficiency after Two Stage Filtration equation looks like with Values.

Here is how the Final Efficiency after Two Stage Filtration equation looks like with Units.

Here is how the Final Efficiency after Two Stage Filtration equation looks like.

100Edit=(1001+(0.00441-99.5Edit)3Edit0.63Edit1.116Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Final Efficiency after Two Stage Filtration

Final Efficiency after Two Stage Filtration Solution

Follow our step by step solution on how to calculate Final Efficiency after Two Stage Filtration?

FIRST Step Consider the formula
E2=(1001+(0.00441-E1)Y'VTF)
Next Step Substitute values of Variables
E2=(1001+(0.00441-99.5)3kg/d0.631.116)
Next Step Convert Units
E2=(1001+(0.00441-99.5)3.5E-5kg/s0.631.116)
Next Step Prepare to Evaluate
E2=(1001+(0.00441-99.5)3.5E-50.631.116)
Next Step Evaluate
E2=100.000031391926
LAST Step Rounding Answer
E2=100

Final Efficiency after Two Stage Filtration Formula Elements

Variables
Functions
Efficiency of Second Filter Stage
Efficiency of second filter stage is the total efficiency obtained from the second trickling filter.
Symbol: E2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Efficiency of First Filter Stage
Efficiency of first filter stage calculates the efficiency of the filter at the first stage.
Symbol: E1
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
BOD in Effluent
BOD in Effluent means total BOD in effluent from 1st stage.
Symbol: Y'
Measurement: Mass Flow RateUnit: kg/d
Note: Value should be greater than 0.
Volume
Volume is the three-dimensional space occupied by a substance or object, such as water, soil, air, or any environmental medium.
Symbol: VT
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Recirculation Factor
Recirculation factor r represents the average number of passes of the influent organic matter through the trickling filter.
Symbol: F
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Efficiency of High Rate Filters category

​Go Recirculation Factor given Recirculation Ratio
F=1+α(1+0.1α)2
​Go Recirculation Factor given Volume of Raw Sewage
F=1+(RI)(1+0.1(RI))2
​Go Recirculation Ratio given Volume of Raw Sewage
α=RI
​Go Volume of Raw Sewage given Recirculation Ratio
I=Rα

How to Evaluate Final Efficiency after Two Stage Filtration?

Final Efficiency after Two Stage Filtration evaluator uses Efficiency of Second Filter Stage = (100/(1+(0.0044/(1-Efficiency of First Filter Stage))*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))) to evaluate the Efficiency of Second Filter Stage, The Final Efficiency after Two Stage Filtration formula is defined as the effectiveness of a filtration system in removing contaminants from water after undergoing two stages of filtration. Efficiency of Second Filter Stage is denoted by E2 symbol.

How to evaluate Final Efficiency after Two Stage Filtration using this online evaluator? To use this online evaluator for Final Efficiency after Two Stage Filtration, enter Efficiency of First Filter Stage (E1), BOD in Effluent (Y'), Volume (VT) & Recirculation Factor (F) and hit the calculate button.

FAQs on Final Efficiency after Two Stage Filtration

What is the formula to find Final Efficiency after Two Stage Filtration?
The formula of Final Efficiency after Two Stage Filtration is expressed as Efficiency of Second Filter Stage = (100/(1+(0.0044/(1-Efficiency of First Filter Stage))*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))). Here is an example- 100 = (100/(1+(0.0044/(1-99.5))*sqrt(3.47222222222222E-05/(0.63*1.116)))).
How to calculate Final Efficiency after Two Stage Filtration?
With Efficiency of First Filter Stage (E1), BOD in Effluent (Y'), Volume (VT) & Recirculation Factor (F) we can find Final Efficiency after Two Stage Filtration using the formula - Efficiency of Second Filter Stage = (100/(1+(0.0044/(1-Efficiency of First Filter Stage))*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))). This formula also uses Square Root (sqrt) function(s).
Copied!