Fault Impedance Line is defined as the impedance that caused the fault. Check FAQs
Zf(line)=V1(line)+V2(line)+V0(line)Ia(line)
Zf(line) - Fault Impedance Line?V1(line) - Positive Sequence Voltage Line?V2(line) - Negative Sequence Voltage Line?V0(line) - Zero Sequence Voltage Line?Ia(line) - A-Phase Current Line?

Fault Impedance using A-Phase Current Example

With values
With units
Only example

Here is how the Fault Impedance using A-Phase Current equation looks like with Values.

Here is how the Fault Impedance using A-Phase Current equation looks like with Units.

Here is how the Fault Impedance using A-Phase Current equation looks like.

7.8313Edit=13.51Edit+16.056Edit+17.5Edit6.01Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Fault Impedance using A-Phase Current

Fault Impedance using A-Phase Current Solution

Follow our step by step solution on how to calculate Fault Impedance using A-Phase Current?

FIRST Step Consider the formula
Zf(line)=V1(line)+V2(line)+V0(line)Ia(line)
Next Step Substitute values of Variables
Zf(line)=13.51V+16.056V+17.5V6.01A
Next Step Prepare to Evaluate
Zf(line)=13.51+16.056+17.56.01
Next Step Evaluate
Zf(line)=7.83128119800333Ω
LAST Step Rounding Answer
Zf(line)=7.8313Ω

Fault Impedance using A-Phase Current Formula Elements

Variables
Fault Impedance Line
Fault Impedance Line is defined as the impedance that caused the fault.
Symbol: Zf(line)
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Positive Sequence Voltage Line
Positive Sequence Voltage Line is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1(line)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Negative Sequence Voltage Line
Negative Sequence Voltage Line is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
Symbol: V2(line)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Zero Sequence Voltage Line
Zero Sequence Voltage Line is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.
Symbol: V0(line)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
A-Phase Current Line
A-phase Current Line is the current that flows into the a-phase in open conductor fault.
Symbol: Ia(line)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Fault Impedance Line

​Go Fault Impedance using Positive Sequence Current
Zf(line)=V1(line)+V2(line)+V0(line)3I1(line)

Other formulas in Line Sequence Impedance category

​Go Zero Sequence Impedance for Star Connected Load
Z0S(line)=Zs(line)+(3Zf(line))
​Go Positive Sequence Impedance for Delta Connected Load
Z1(line)=V1(line)I1(line)
​Go Negative Sequence Impedance for Delta Connected Load
Z2(line)=V2(line)I2(line)
​Go Zero Sequence Impedance for Delta Connected Load
Z0D(line)=V0(line)I0(line)

How to Evaluate Fault Impedance using A-Phase Current?

Fault Impedance using A-Phase Current evaluator uses Fault Impedance Line = (Positive Sequence Voltage Line+Negative Sequence Voltage Line+Zero Sequence Voltage Line)/A-Phase Current Line to evaluate the Fault Impedance Line, The Fault Impedance using a-phase current formula is defined as the impedence of the path followed by fault current when a low impedance fault occurs between the phase conductor and earth. Fault Impedance Line is denoted by Zf(line) symbol.

How to evaluate Fault Impedance using A-Phase Current using this online evaluator? To use this online evaluator for Fault Impedance using A-Phase Current, enter Positive Sequence Voltage Line (V1(line)), Negative Sequence Voltage Line (V2(line)), Zero Sequence Voltage Line (V0(line)) & A-Phase Current Line (Ia(line)) and hit the calculate button.

FAQs on Fault Impedance using A-Phase Current

What is the formula to find Fault Impedance using A-Phase Current?
The formula of Fault Impedance using A-Phase Current is expressed as Fault Impedance Line = (Positive Sequence Voltage Line+Negative Sequence Voltage Line+Zero Sequence Voltage Line)/A-Phase Current Line. Here is an example- 7.831281 = (13.51+16.056+17.5)/6.01.
How to calculate Fault Impedance using A-Phase Current?
With Positive Sequence Voltage Line (V1(line)), Negative Sequence Voltage Line (V2(line)), Zero Sequence Voltage Line (V0(line)) & A-Phase Current Line (Ia(line)) we can find Fault Impedance using A-Phase Current using the formula - Fault Impedance Line = (Positive Sequence Voltage Line+Negative Sequence Voltage Line+Zero Sequence Voltage Line)/A-Phase Current Line.
What are the other ways to Calculate Fault Impedance Line?
Here are the different ways to Calculate Fault Impedance Line-
  • Fault Impedance Line=(Positive Sequence Voltage Line+Negative Sequence Voltage Line+Zero Sequence Voltage Line)/(3*Positive Sequence Current Line)OpenImg
Can the Fault Impedance using A-Phase Current be negative?
No, the Fault Impedance using A-Phase Current, measured in Electric Resistance cannot be negative.
Which unit is used to measure Fault Impedance using A-Phase Current?
Fault Impedance using A-Phase Current is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Fault Impedance using A-Phase Current can be measured.
Copied!