Equivalent Reactance of Transformer from Secondary Side Formula

Fx Copy
LaTeX Copy
The Equivalent Reactance from Secondary side is the total Reactance of the Secondary side. Check FAQs
X02=XL2+X'1
X02 - Equivalent Reactance from Secondary?XL2 - Secondary Leakage Reactance?X'1 - Reactance of Primary in Secondary?

Equivalent Reactance of Transformer from Secondary Side Example

With values
With units
Only example

Here is how the Equivalent Reactance of Transformer from Secondary Side equation looks like with Values.

Here is how the Equivalent Reactance of Transformer from Secondary Side equation looks like with Units.

Here is how the Equivalent Reactance of Transformer from Secondary Side equation looks like.

2.23Edit=0.95Edit+1.28Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Equivalent Reactance of Transformer from Secondary Side

Equivalent Reactance of Transformer from Secondary Side Solution

Follow our step by step solution on how to calculate Equivalent Reactance of Transformer from Secondary Side?

FIRST Step Consider the formula
X02=XL2+X'1
Next Step Substitute values of Variables
X02=0.95Ω+1.28Ω
Next Step Prepare to Evaluate
X02=0.95+1.28
LAST Step Evaluate
X02=2.23Ω

Equivalent Reactance of Transformer from Secondary Side Formula Elements

Variables
Equivalent Reactance from Secondary
The Equivalent Reactance from Secondary side is the total Reactance of the Secondary side.
Symbol: X02
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Secondary Leakage Reactance
Secondary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Symbol: XL2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Reactance of Primary in Secondary
Reactance of Primary in Secondary referred to as secondary is the Reactance of Primary winding in Secondary.
Symbol: X'1
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.

Other formulas in Reactance category

​Go Equivalent Reactance of Transformer from Primary Side
X01=XL1+X'2
​Go Primary Leakage Reactance
XL1=X'1K2
​Go Reactance of Primary Winding in Secondary
X'1=XL1K2
​Go Reactance of Secondary Winding in Primary
X'2=XL2K2

How to Evaluate Equivalent Reactance of Transformer from Secondary Side?

Equivalent Reactance of Transformer from Secondary Side evaluator uses Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary to evaluate the Equivalent Reactance from Secondary, The Equivalent Reactance of Transformer from Secondary Side formula is defined as the sum of the reactance of secondary winding and Reactance of Primary winding in Secondary. Equivalent Reactance from Secondary is denoted by X02 symbol.

How to evaluate Equivalent Reactance of Transformer from Secondary Side using this online evaluator? To use this online evaluator for Equivalent Reactance of Transformer from Secondary Side, enter Secondary Leakage Reactance (XL2) & Reactance of Primary in Secondary (X'1) and hit the calculate button.

FAQs on Equivalent Reactance of Transformer from Secondary Side

What is the formula to find Equivalent Reactance of Transformer from Secondary Side?
The formula of Equivalent Reactance of Transformer from Secondary Side is expressed as Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary. Here is an example- 2.23 = 0.95+1.28.
How to calculate Equivalent Reactance of Transformer from Secondary Side?
With Secondary Leakage Reactance (XL2) & Reactance of Primary in Secondary (X'1) we can find Equivalent Reactance of Transformer from Secondary Side using the formula - Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary.
Can the Equivalent Reactance of Transformer from Secondary Side be negative?
No, the Equivalent Reactance of Transformer from Secondary Side, measured in Electric Resistance cannot be negative.
Which unit is used to measure Equivalent Reactance of Transformer from Secondary Side?
Equivalent Reactance of Transformer from Secondary Side is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Equivalent Reactance of Transformer from Secondary Side can be measured.