Fx Copy
LaTeX Copy
The Equivalent Reactance from Primary side is the total Reactance of the primary side. Check FAQs
X01=Z012-R012
X01 - Equivalent Reactance from Primary?Z01 - Equivalent Impedance from Primary?R01 - Equivalent Resistance from Primary?

Equivalent Reactance from Primary Side given Equivalent Impedance Example

With values
With units
Only example

Here is how the Equivalent Reactance from Primary Side given Equivalent Impedance equation looks like with Values.

Here is how the Equivalent Reactance from Primary Side given Equivalent Impedance equation looks like with Units.

Here is how the Equivalent Reactance from Primary Side given Equivalent Impedance equation looks like.

1.4694Edit=36Edit2-35.97Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Equivalent Reactance from Primary Side given Equivalent Impedance

Equivalent Reactance from Primary Side given Equivalent Impedance Solution

Follow our step by step solution on how to calculate Equivalent Reactance from Primary Side given Equivalent Impedance?

FIRST Step Consider the formula
X01=Z012-R012
Next Step Substitute values of Variables
X01=36Ω2-35.97Ω2
Next Step Prepare to Evaluate
X01=362-35.972
Next Step Evaluate
X01=1.46938762755104Ω
LAST Step Rounding Answer
X01=1.4694Ω

Equivalent Reactance from Primary Side given Equivalent Impedance Formula Elements

Variables
Functions
Equivalent Reactance from Primary
The Equivalent Reactance from Primary side is the total Reactance of the primary side.
Symbol: X01
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Equivalent Impedance from Primary
The Equivalent Impedance from Primary side is the total Impedance of the primary side.
Symbol: Z01
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Equivalent Resistance from Primary
The Equivalent Resistance from Primary side is the total resistance of the primary side.
Symbol: R01
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Equivalent Reactance from Primary

​Go Equivalent Reactance of Transformer from Primary Side
X01=XL1+X'2

Other formulas in Reactance category

​Go Reactance of Primary in Secondary using Equivalent Reactance from Secondary Side
X'1=X02-XL2
​Go Reactance of Secondary in Primary using Equivalent Reactance from Primary Side
X'2=X01-XL1
​Go Secondary Leakage Reactance given Equivalent Reactance from Secondary Side
XL2=X02-XL1K2
​Go Primary Leakage Reactance using Equivalent Reactance from Primary Side
XL1=X01-X'2

How to Evaluate Equivalent Reactance from Primary Side given Equivalent Impedance?

Equivalent Reactance from Primary Side given Equivalent Impedance evaluator uses Equivalent Reactance from Primary = sqrt(Equivalent Impedance from Primary^2-Equivalent Resistance from Primary^2) to evaluate the Equivalent Reactance from Primary, The Equivalent Reactance from Primary Side given Equivalent Impedance formula is defined as the sum of Reactance of Secondary winding in primary and primary winding reactance. Equivalent Reactance from Primary is denoted by X01 symbol.

How to evaluate Equivalent Reactance from Primary Side given Equivalent Impedance using this online evaluator? To use this online evaluator for Equivalent Reactance from Primary Side given Equivalent Impedance, enter Equivalent Impedance from Primary (Z01) & Equivalent Resistance from Primary (R01) and hit the calculate button.

FAQs on Equivalent Reactance from Primary Side given Equivalent Impedance

What is the formula to find Equivalent Reactance from Primary Side given Equivalent Impedance?
The formula of Equivalent Reactance from Primary Side given Equivalent Impedance is expressed as Equivalent Reactance from Primary = sqrt(Equivalent Impedance from Primary^2-Equivalent Resistance from Primary^2). Here is an example- 1.469388 = sqrt(36^2-35.97^2).
How to calculate Equivalent Reactance from Primary Side given Equivalent Impedance?
With Equivalent Impedance from Primary (Z01) & Equivalent Resistance from Primary (R01) we can find Equivalent Reactance from Primary Side given Equivalent Impedance using the formula - Equivalent Reactance from Primary = sqrt(Equivalent Impedance from Primary^2-Equivalent Resistance from Primary^2). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Equivalent Reactance from Primary?
Here are the different ways to Calculate Equivalent Reactance from Primary-
  • Equivalent Reactance from Primary=Primary Leakage Reactance+Reactance of Secondary in PrimaryOpenImg
Can the Equivalent Reactance from Primary Side given Equivalent Impedance be negative?
No, the Equivalent Reactance from Primary Side given Equivalent Impedance, measured in Electric Resistance cannot be negative.
Which unit is used to measure Equivalent Reactance from Primary Side given Equivalent Impedance?
Equivalent Reactance from Primary Side given Equivalent Impedance is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Equivalent Reactance from Primary Side given Equivalent Impedance can be measured.
Copied!