Fx Copy
LaTeX Copy
The Water Level Fluctuation refers to the irregular rising and falling in number or amount of water during monsoon season. Check FAQs
h=RG-DG-B+Is+IASY
h - Water Level Fluctuation?RG - Gross Recharge due to Rainfall?DG - Gross Water Draft?B - Base Flow into the Stream from the Area?Is - Recharge of Ground Water Body?I - Net Ground Water Flowing Outside Catchment?A - Watershed Area?SY - Specific Yield?

Equation for Water Level Fluctuation Example

With values
With units
Only example

Here is how the Equation for Water Level Fluctuation equation looks like with Values.

Here is how the Equation for Water Level Fluctuation equation looks like with Units.

Here is how the Equation for Water Level Fluctuation equation looks like.

5Edit=45Edit-10Edit-6Edit+18Edit+12Edit20Edit0.59Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Equation for Water Level Fluctuation

Equation for Water Level Fluctuation Solution

Follow our step by step solution on how to calculate Equation for Water Level Fluctuation?

FIRST Step Consider the formula
h=RG-DG-B+Is+IASY
Next Step Substitute values of Variables
h=45m³/s-10m³/s-6m³/s+18m³/s+12m³/s200.59
Next Step Prepare to Evaluate
h=45-10-6+18+12200.59
LAST Step Evaluate
h=5m

Equation for Water Level Fluctuation Formula Elements

Variables
Water Level Fluctuation
The Water Level Fluctuation refers to the irregular rising and falling in number or amount of water during monsoon season.
Symbol: h
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Gross Recharge due to Rainfall
The Gross Recharge due to Rainfall refers to the total amount of water that infiltrates the ground as a result of precipitation.
Symbol: RG
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Gross Water Draft
The Gross Water Draft refers to the total volume of water extracted or utilized from a catchment area.
Symbol: DG
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Base Flow into the Stream from the Area
The Base Flow into the Stream from the Area refers to the flow that is not runoff, it is water from the ground, flowing into the channel over a long time and with a certain delay.
Symbol: B
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Recharge of Ground Water Body
The Recharge of Ground Water Body from the stream refers to the hydrologic process, where water moves downward from surface water to groundwater.
Symbol: Is
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Net Ground Water Flowing Outside Catchment
The Net Ground Water Flowing Outside Catchment refers to the steady-state groundwater flow through aquifers.
Symbol: I
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Watershed Area
The Watershed Area refers to the isolated area with a well demarcated boundary line, draining the rainwater to a single outlet.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Specific Yield
The Specific Yield refers to the volume of water that a saturated rock or soil will yield due to gravity drainage to the total volume of the rock or soil.
Symbol: SY
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Water Level Fluctuation

​Go Water Level Fluctuation when Possible Recharge and Gross Water Draft is Considered
h=R+DGSYA

Other formulas in Groundwater Level Fluctuation category

​Go Equation for Specific Yield
SY=RG-DG-B+Is+IAh
​Go Equation for Gross Recharge due to Rainfall and other Sources
RG=(hSYA)+DG+B-Is-I

How to Evaluate Equation for Water Level Fluctuation?

Equation for Water Level Fluctuation evaluator uses Water Level Fluctuation = (Gross Recharge due to Rainfall-Gross Water Draft-Base Flow into the Stream from the Area+Recharge of Ground Water Body+Net Ground Water Flowing Outside Catchment)/(Watershed Area*Specific Yield) to evaluate the Water Level Fluctuation, The Equation for Water Level Fluctuation formula is defined as the difference in water accumulation by comparison during a monsoon season. Water Level Fluctuation is denoted by h symbol.

How to evaluate Equation for Water Level Fluctuation using this online evaluator? To use this online evaluator for Equation for Water Level Fluctuation, enter Gross Recharge due to Rainfall (RG), Gross Water Draft (DG), Base Flow into the Stream from the Area (B), Recharge of Ground Water Body (Is), Net Ground Water Flowing Outside Catchment (I), Watershed Area (A) & Specific Yield (SY) and hit the calculate button.

FAQs on Equation for Water Level Fluctuation

What is the formula to find Equation for Water Level Fluctuation?
The formula of Equation for Water Level Fluctuation is expressed as Water Level Fluctuation = (Gross Recharge due to Rainfall-Gross Water Draft-Base Flow into the Stream from the Area+Recharge of Ground Water Body+Net Ground Water Flowing Outside Catchment)/(Watershed Area*Specific Yield). Here is an example- 5 = (45-10-6+18+12)/(20*0.59).
How to calculate Equation for Water Level Fluctuation?
With Gross Recharge due to Rainfall (RG), Gross Water Draft (DG), Base Flow into the Stream from the Area (B), Recharge of Ground Water Body (Is), Net Ground Water Flowing Outside Catchment (I), Watershed Area (A) & Specific Yield (SY) we can find Equation for Water Level Fluctuation using the formula - Water Level Fluctuation = (Gross Recharge due to Rainfall-Gross Water Draft-Base Flow into the Stream from the Area+Recharge of Ground Water Body+Net Ground Water Flowing Outside Catchment)/(Watershed Area*Specific Yield).
What are the other ways to Calculate Water Level Fluctuation?
Here are the different ways to Calculate Water Level Fluctuation-
  • Water Level Fluctuation=(Possible Recharge+Gross Water Draft)/(Specific Yield*Watershed Area)OpenImg
Can the Equation for Water Level Fluctuation be negative?
Yes, the Equation for Water Level Fluctuation, measured in Length can be negative.
Which unit is used to measure Equation for Water Level Fluctuation?
Equation for Water Level Fluctuation is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Equation for Water Level Fluctuation can be measured.
Copied!