Equation for Punching Shear Design Formula

Fx Copy
LaTeX Copy
Punching Shear is a type of failure of reinforced concrete slabs subjected to high localized forces. Check FAQs
ϕVn=φ(Vc+Vs)
ϕVn - Punching Shear?φ - Capacity Reduction Factor?Vc - Nominal Shear Strength of Concrete?Vs - Nominal Shear Strength by Reinforcement?

Equation for Punching Shear Design Example

With values
With units
Only example

Here is how the Equation for Punching Shear Design equation looks like with Values.

Here is how the Equation for Punching Shear Design equation looks like with Units.

Here is how the Equation for Punching Shear Design equation looks like.

161.5Edit=0.85Edit(90Edit+100Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Equation for Punching Shear Design

Equation for Punching Shear Design Solution

Follow our step by step solution on how to calculate Equation for Punching Shear Design?

FIRST Step Consider the formula
ϕVn=φ(Vc+Vs)
Next Step Substitute values of Variables
ϕVn=0.85(90MPa+100MPa)
Next Step Convert Units
ϕVn=0.85(9E+7Pa+1E+8Pa)
Next Step Prepare to Evaluate
ϕVn=0.85(9E+7+1E+8)
Next Step Evaluate
ϕVn=161500000Pa
LAST Step Convert to Output's Unit
ϕVn=161.5MPa

Equation for Punching Shear Design Formula Elements

Variables
Punching Shear
Punching Shear is a type of failure of reinforced concrete slabs subjected to high localized forces.
Symbol: ϕVn
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Capacity Reduction Factor
The Capacity Reduction Factor is a safety factor to account for uncertainties in material strength.
Symbol: φ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Nominal Shear Strength of Concrete
The Nominal Shear Strength of Concrete is the capacity of the concrete section to resist the effects of load.
Symbol: Vc
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.
Nominal Shear Strength by Reinforcement
Nominal Shear Strength by Reinforcement is the strength or capacity of shear reinforcement to withstand shear or diagonal stresses.
Symbol: Vs
Measurement: PressureUnit: MPa
Note: Value should be greater than 0.

Other formulas in Design of Two Way Slab System category

​Go Concrete Shear Strength at Critical Sections
V=(2(fc)12)d'bo
​Go Maximum Slab thickness
h=(ln36)(0.8+fysteel200000)

How to Evaluate Equation for Punching Shear Design?

Equation for Punching Shear Design evaluator uses Punching Shear = Capacity Reduction Factor*(Nominal Shear Strength of Concrete+Nominal Shear Strength by Reinforcement) to evaluate the Punching Shear, The Equation for Punching Shear Design formula is defined as the value of punching shear which is a type of failure of reinforced concrete slabs subjected to high localized forces. Punching Shear is denoted by ϕVn symbol.

How to evaluate Equation for Punching Shear Design using this online evaluator? To use this online evaluator for Equation for Punching Shear Design, enter Capacity Reduction Factor (φ), Nominal Shear Strength of Concrete (Vc) & Nominal Shear Strength by Reinforcement (Vs) and hit the calculate button.

FAQs on Equation for Punching Shear Design

What is the formula to find Equation for Punching Shear Design?
The formula of Equation for Punching Shear Design is expressed as Punching Shear = Capacity Reduction Factor*(Nominal Shear Strength of Concrete+Nominal Shear Strength by Reinforcement). Here is an example- 0.000162 = 0.85*(90000000+100000000).
How to calculate Equation for Punching Shear Design?
With Capacity Reduction Factor (φ), Nominal Shear Strength of Concrete (Vc) & Nominal Shear Strength by Reinforcement (Vs) we can find Equation for Punching Shear Design using the formula - Punching Shear = Capacity Reduction Factor*(Nominal Shear Strength of Concrete+Nominal Shear Strength by Reinforcement).
Can the Equation for Punching Shear Design be negative?
No, the Equation for Punching Shear Design, measured in Pressure cannot be negative.
Which unit is used to measure Equation for Punching Shear Design?
Equation for Punching Shear Design is usually measured using the Megapascal[MPa] for Pressure. Pascal[MPa], Kilopascal[MPa], Bar[MPa] are the few other units in which Equation for Punching Shear Design can be measured.
Copied!