Electrostatic Deflection Sensitivity Formula

Fx Copy
LaTeX Copy
The Electrostatic deflection sensitivity measures the sensitivity of electrostatic deflecting system in cathode ray tube. Check FAQs
Se=LdefLcrt2dVa
Se - Electrostatic Deflection Sensitivity?Ldef - Length of Deflecting Plates?Lcrt - Cathode Ray Tube Length?d - Distance between Deflecting Plates?Va - Anode Voltage?

Electrostatic Deflection Sensitivity Example

With values
With units
Only example

Here is how the Electrostatic Deflection Sensitivity equation looks like with Values.

Here is how the Electrostatic Deflection Sensitivity equation looks like with Units.

Here is how the Electrostatic Deflection Sensitivity equation looks like.

0.0013Edit=50Edit0.012Edit22.5Edit90Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category EDC » fx Electrostatic Deflection Sensitivity

Electrostatic Deflection Sensitivity Solution

Follow our step by step solution on how to calculate Electrostatic Deflection Sensitivity?

FIRST Step Consider the formula
Se=LdefLcrt2dVa
Next Step Substitute values of Variables
Se=50m0.012mm22.5mm90V
Next Step Convert Units
Se=50m1.2E-5m20.0025m90V
Next Step Prepare to Evaluate
Se=501.2E-520.002590
Next Step Evaluate
Se=0.00133333333333333m/V
LAST Step Rounding Answer
Se=0.0013m/V

Electrostatic Deflection Sensitivity Formula Elements

Variables
Electrostatic Deflection Sensitivity
The Electrostatic deflection sensitivity measures the sensitivity of electrostatic deflecting system in cathode ray tube.
Symbol: Se
Measurement: Deflection SensitivityUnit: m/V
Note: Value can be positive or negative.
Length of Deflecting Plates
The Length of deflecting plates in cathode ray tube is used to measure the electrostatic deflection as well as its sensitivity.
Symbol: Ldef
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Cathode Ray Tube Length
The Cathode Ray Tube Length is the distance between the screen and the center of the deflecting plated in a cathode ray tube.
Symbol: Lcrt
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Distance between Deflecting Plates
Distance between deflecting plates in Cathode ray tube is used to measure the electrostatic deflection as well as its sensitivity.
Symbol: d
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Anode Voltage
The Anode Voltage refers to the voltage of pre-accelerating anode of an electron when it moves in a cathode ray tube.
Symbol: Va
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in Electrostatic Parameters category

​Go Magnetic Deflection Sensitivity
Sm=(LdefLcrt)([Charge-e]2[Mass-e]Va)
​Go Particle Acceleration
ap=[Charge-e]EI[Mass-e]
​Go Radius of Electron on Circular Path
re=[Mass-e]VeH[Charge-e]
​Go Diameter of Cycloid
Dc=2R

How to Evaluate Electrostatic Deflection Sensitivity?

Electrostatic Deflection Sensitivity evaluator uses Electrostatic Deflection Sensitivity = (Length of Deflecting Plates*Cathode Ray Tube Length)/(2*Distance between Deflecting Plates*Anode Voltage) to evaluate the Electrostatic Deflection Sensitivity, The Electrostatic Deflection Sensitivity in cathode ray tube is defined as the deflection of the beam on the screen per unit deflection voltage. Electrostatic Deflection Sensitivity is denoted by Se symbol.

How to evaluate Electrostatic Deflection Sensitivity using this online evaluator? To use this online evaluator for Electrostatic Deflection Sensitivity, enter Length of Deflecting Plates (Ldef), Cathode Ray Tube Length (Lcrt), Distance between Deflecting Plates (d) & Anode Voltage (Va) and hit the calculate button.

FAQs on Electrostatic Deflection Sensitivity

What is the formula to find Electrostatic Deflection Sensitivity?
The formula of Electrostatic Deflection Sensitivity is expressed as Electrostatic Deflection Sensitivity = (Length of Deflecting Plates*Cathode Ray Tube Length)/(2*Distance between Deflecting Plates*Anode Voltage). Here is an example- 0.001333 = (50*1.2E-05)/(2*0.0025*90).
How to calculate Electrostatic Deflection Sensitivity?
With Length of Deflecting Plates (Ldef), Cathode Ray Tube Length (Lcrt), Distance between Deflecting Plates (d) & Anode Voltage (Va) we can find Electrostatic Deflection Sensitivity using the formula - Electrostatic Deflection Sensitivity = (Length of Deflecting Plates*Cathode Ray Tube Length)/(2*Distance between Deflecting Plates*Anode Voltage).
Can the Electrostatic Deflection Sensitivity be negative?
Yes, the Electrostatic Deflection Sensitivity, measured in Deflection Sensitivity can be negative.
Which unit is used to measure Electrostatic Deflection Sensitivity?
Electrostatic Deflection Sensitivity is usually measured using the Meter per Volt[m/V] for Deflection Sensitivity. Centimeter per Volt[m/V] are the few other units in which Electrostatic Deflection Sensitivity can be measured.
Copied!