Electrical efficiency is a measure of the ratio between the useful electrical energy output and the total electrical energy input of an electrical device or system. Check FAQs
ηe=PoPconv
ηe - Electrical Efficiency?Po - Output Power?Pconv - Converted Power?

Electrical Efficiency of DC Shunt Generator Example

With values
With units
Only example

Here is how the Electrical Efficiency of DC Shunt Generator equation looks like with Values.

Here is how the Electrical Efficiency of DC Shunt Generator equation looks like with Units.

Here is how the Electrical Efficiency of DC Shunt Generator equation looks like.

0.9333Edit=238Edit255Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Electrical Efficiency of DC Shunt Generator

Electrical Efficiency of DC Shunt Generator Solution

Follow our step by step solution on how to calculate Electrical Efficiency of DC Shunt Generator?

FIRST Step Consider the formula
ηe=PoPconv
Next Step Substitute values of Variables
ηe=238W255W
Next Step Prepare to Evaluate
ηe=238255
Next Step Evaluate
ηe=0.933333333333333
LAST Step Rounding Answer
ηe=0.9333

Electrical Efficiency of DC Shunt Generator Formula Elements

Variables
Electrical Efficiency
Electrical efficiency is a measure of the ratio between the useful electrical energy output and the total electrical energy input of an electrical device or system.
Symbol: ηe
Measurement: NAUnit: Unitless
Note: Value should be less than 1.0001.
Output Power
Output Power refers to the product of current and voltage at the output terminal of a dc generator.
Symbol: Po
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Converted Power
Converted Power refers to the electrical power output that is generated by the conversion of mechanical energy into electrical energy.
Symbol: Pconv
Measurement: PowerUnit: W
Note: Value can be positive or negative.

Other formulas in Efficiency category

​Go Overall Efficiency in DC Shunt Generator
ηo=PoPin

How to Evaluate Electrical Efficiency of DC Shunt Generator?

Electrical Efficiency of DC Shunt Generator evaluator uses Electrical Efficiency = Output Power/Converted Power to evaluate the Electrical Efficiency, The Electrical Efficiency of DC shunt Generator is dependent on output power and the converted power in armature. Electrical Efficiency is denoted by ηe symbol.

How to evaluate Electrical Efficiency of DC Shunt Generator using this online evaluator? To use this online evaluator for Electrical Efficiency of DC Shunt Generator, enter Output Power (Po) & Converted Power (Pconv) and hit the calculate button.

FAQs on Electrical Efficiency of DC Shunt Generator

What is the formula to find Electrical Efficiency of DC Shunt Generator?
The formula of Electrical Efficiency of DC Shunt Generator is expressed as Electrical Efficiency = Output Power/Converted Power. Here is an example- 0.933333 = 238/255.
How to calculate Electrical Efficiency of DC Shunt Generator?
With Output Power (Po) & Converted Power (Pconv) we can find Electrical Efficiency of DC Shunt Generator using the formula - Electrical Efficiency = Output Power/Converted Power.
Copied!