Effluent BOD given Oxygen Demand of Biomass Formula

Fx Copy
LaTeX Copy
Effluent BOD given Oxygen Demand of Biomass is the amount of oxygen that is consumed by the microbial population in the effluent to decompose organic matter present. Check FAQs
Qb=Qi-(f(O2+(DO2QwXR))SF)
Qb - Effluent BOD given Oxygen Demand of Biomass?Qi - Influent BOD?f - Ratio of BOD to Ultimate BOD?O2 - Theoretical Oxygen Requirement?DO2 - Oxygen Demand of Biomass?Qw - Volume of Wasted Sludge per day?XR - MLSS in Returned or Wasted Sludge?SF - Sewage Flowrate?

Effluent BOD given Oxygen Demand of Biomass Example

With values
With units
Only example

Here is how the Effluent BOD given Oxygen Demand of Biomass equation looks like with Values.

Here is how the Effluent BOD given Oxygen Demand of Biomass equation looks like with Units.

Here is how the Effluent BOD given Oxygen Demand of Biomass equation looks like.

7.8268Edit=13.2Edit-(3Edit(2.5Edit+(2.02Edit9.5Edit1.4Edit))15Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Effluent BOD given Oxygen Demand of Biomass

Effluent BOD given Oxygen Demand of Biomass Solution

Follow our step by step solution on how to calculate Effluent BOD given Oxygen Demand of Biomass?

FIRST Step Consider the formula
Qb=Qi-(f(O2+(DO2QwXR))SF)
Next Step Substitute values of Variables
Qb=13.2mg/L-(3(2.5mg/d+(2.029.5m³/s1.4mg/L))15m³/s)
Next Step Convert Units
Qb=0.0132kg/m³-(3(2.9E-11kg/s+(2.029.5m³/s0.0014kg/m³))15m³/s)
Next Step Prepare to Evaluate
Qb=0.0132-(3(2.9E-11+(2.029.50.0014))15)
Next Step Evaluate
Qb=0.00782679999421296kg/m³
Next Step Convert to Output's Unit
Qb=7.82679999421296mg/L
LAST Step Rounding Answer
Qb=7.8268mg/L

Effluent BOD given Oxygen Demand of Biomass Formula Elements

Variables
Effluent BOD given Oxygen Demand of Biomass
Effluent BOD given Oxygen Demand of Biomass is the amount of oxygen that is consumed by the microbial population in the effluent to decompose organic matter present.
Symbol: Qb
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Ratio of BOD to Ultimate BOD
Ratio of BOD to Ultimate BOD is the ratio of 5 days bod to ultimate bod.
Symbol: f
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Theoretical Oxygen Requirement
Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products.
Symbol: O2
Measurement: Mass Flow RateUnit: mg/d
Note: Value should be greater than 0.
Oxygen Demand of Biomass
Oxygen Demand of Biomass is the amount of oxygen required by the microorganisms to decompose organic matter present in biomass.
Symbol: DO2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Volume of Wasted Sludge per day
Volume of Wasted Sludge per day is the amount of sludge that is removed or wasted from a wastewater treatment process on a daily basis.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
MLSS in Returned or Wasted Sludge
MLSS in Returned or Wasted Sludge is the mixed liquor suspended solids in returned sludge in terms of mg per liter.
Symbol: XR
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Sewage Flowrate
Sewage Flowrate is the flow rate of sewage when it is being discharged in the river.
Symbol: SF
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other formulas in Effluent BOD category

​Go Effluent BOD given Oxygen Required in Aeration Tank
Qo=Qi-(f(O2+(1.42QwXR))SF)
​Go Effluent BOD given Ultimate BOD
Qub=Qi-((BOD5BODu)(O2+(1.42QwXR))SF)

How to Evaluate Effluent BOD given Oxygen Demand of Biomass?

Effluent BOD given Oxygen Demand of Biomass evaluator uses Effluent BOD given Oxygen Demand of Biomass = Influent BOD-((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Flowrate) to evaluate the Effluent BOD given Oxygen Demand of Biomass, The Effluent BOD given Oxygen Demand of Biomass formula is defined as the amount of oxygen that is consumed by the microbial population in the effluent to decompose organic matter present in the wastewater. When considering the oxygen demand of biomass, it specifically accounts for the amount of oxygen required by the microbial community to metabolize the organic substrates. Effluent BOD given Oxygen Demand of Biomass is denoted by Qb symbol.

How to evaluate Effluent BOD given Oxygen Demand of Biomass using this online evaluator? To use this online evaluator for Effluent BOD given Oxygen Demand of Biomass, enter Influent BOD (Qi), Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2), Oxygen Demand of Biomass (DO2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Flowrate (SF) and hit the calculate button.

FAQs on Effluent BOD given Oxygen Demand of Biomass

What is the formula to find Effluent BOD given Oxygen Demand of Biomass?
The formula of Effluent BOD given Oxygen Demand of Biomass is expressed as Effluent BOD given Oxygen Demand of Biomass = Influent BOD-((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Flowrate). Here is an example- 7826.8 = 0.0132-((3*(2.89351851851852E-11+(2.02*9.5*0.0014)))/15).
How to calculate Effluent BOD given Oxygen Demand of Biomass?
With Influent BOD (Qi), Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2), Oxygen Demand of Biomass (DO2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Flowrate (SF) we can find Effluent BOD given Oxygen Demand of Biomass using the formula - Effluent BOD given Oxygen Demand of Biomass = Influent BOD-((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Flowrate).
Can the Effluent BOD given Oxygen Demand of Biomass be negative?
No, the Effluent BOD given Oxygen Demand of Biomass, measured in Density cannot be negative.
Which unit is used to measure Effluent BOD given Oxygen Demand of Biomass?
Effluent BOD given Oxygen Demand of Biomass is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Effluent BOD given Oxygen Demand of Biomass can be measured.
Copied!