Effluent BOD given Mass of Wasted Activated Sludge Formula

Fx Copy
LaTeX Copy
Effluent BOD is the amount of BOD present in the outing sewage. Check FAQs
Qo=Qi-(Mws+(KeVX')YQs)
Qo - Effluent BOD?Qi - Influent BOD?Mws - Mass of Wasted Activated Sludge?Ke - Endogenous Respiration Rate Constant?V - Volume of Tank?X' - Mixed Liquor Suspended Solids?Y - Maximum Yield Coefficient?Qs - Sewage Discharge?

Effluent BOD given Mass of Wasted Activated Sludge Example

With values
With units
Only example

Here is how the Effluent BOD given Mass of Wasted Activated Sludge equation looks like with Values.

Here is how the Effluent BOD given Mass of Wasted Activated Sludge equation looks like with Units.

Here is how the Effluent BOD given Mass of Wasted Activated Sludge equation looks like.

0.4001Edit=11.2Edit-(53626Edit+(2.99Edit9Edit1200Edit)0.5Edit10Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Effluent BOD given Mass of Wasted Activated Sludge

Effluent BOD given Mass of Wasted Activated Sludge Solution

Follow our step by step solution on how to calculate Effluent BOD given Mass of Wasted Activated Sludge?

FIRST Step Consider the formula
Qo=Qi-(Mws+(KeVX')YQs)
Next Step Substitute values of Variables
Qo=11.2mg/L-(53626mg+(2.99d⁻¹91200mg/L)0.510m³/s)
Next Step Convert Units
Qo=0.0112kg/m³-(0.0536kg+(3.5E-5s⁻¹91.2kg/m³)0.510m³/s)
Next Step Prepare to Evaluate
Qo=0.0112-(0.0536+(3.5E-591.2)0.510)
Next Step Evaluate
Qo=0.000400050000000001kg/m³
Next Step Convert to Output's Unit
Qo=0.400050000000001mg/L
LAST Step Rounding Answer
Qo=0.4001mg/L

Effluent BOD given Mass of Wasted Activated Sludge Formula Elements

Variables
Effluent BOD
Effluent BOD is the amount of BOD present in the outing sewage.
Symbol: Qo
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Mass of Wasted Activated Sludge
Mass of Wasted Activated Sludge is the total mass of sludge that is removed from the wastewater treatment process, specifically from the activated sludge system.
Symbol: Mws
Measurement: WeightUnit: mg
Note: Value should be greater than 0.
Endogenous Respiration Rate Constant
Endogenous Respiration Rate Constant is used for designing a complete-mix activated-sludge system.
Symbol: Ke
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
Volume of Tank
Volume of Tank is defined as the capacity of flocculation and mixing tank.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Mixed Liquor Suspended Solids
Mixed Liquor Suspended Solids is the concentration of suspended solids in the mixed liquor of an aeration tank during the activated sludge process.
Symbol: X'
Measurement: DensityUnit: mg/L
Note: Value should be between 1000 to 6500.
Maximum Yield Coefficient
Maximum Yield Coefficient is the maximum mg of cells produced per mg organic matter removed.
Symbol: Y
Measurement: NAUnit: Unitless
Note: Value should be between 0.4 to 0.8.
Sewage Discharge
Sewage Discharge is the flow rate of sewage when it is being discharged in the river.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other formulas in Influent and Effluent BOD category

​Go Influent BOD given Specific Substrate Utilization Rate Per Day
Qi'=(UVX'Qs)+Qo
​Go Influent BOD given Mass of Wasted Activated Sludge
Qi=(Mws+(KeVX')YQs)+Qo

How to Evaluate Effluent BOD given Mass of Wasted Activated Sludge?

Effluent BOD given Mass of Wasted Activated Sludge evaluator uses Effluent BOD = Influent BOD-((Mass of Wasted Activated Sludge+(Endogenous Respiration Rate Constant*Volume of Tank*Mixed Liquor Suspended Solids))/(Maximum Yield Coefficient*Sewage Discharge)) to evaluate the Effluent BOD, The Effluent BOD given Mass of Wasted Activated Sludge formula is defined as the calculation of effluent BOD when we have prior information of mass of wasted activated sludge. Effluent BOD is denoted by Qo symbol.

How to evaluate Effluent BOD given Mass of Wasted Activated Sludge using this online evaluator? To use this online evaluator for Effluent BOD given Mass of Wasted Activated Sludge, enter Influent BOD (Qi), Mass of Wasted Activated Sludge (Mws), Endogenous Respiration Rate Constant (Ke), Volume of Tank (V), Mixed Liquor Suspended Solids (X'), Maximum Yield Coefficient (Y) & Sewage Discharge (Qs) and hit the calculate button.

FAQs on Effluent BOD given Mass of Wasted Activated Sludge

What is the formula to find Effluent BOD given Mass of Wasted Activated Sludge?
The formula of Effluent BOD given Mass of Wasted Activated Sludge is expressed as Effluent BOD = Influent BOD-((Mass of Wasted Activated Sludge+(Endogenous Respiration Rate Constant*Volume of Tank*Mixed Liquor Suspended Solids))/(Maximum Yield Coefficient*Sewage Discharge)). Here is an example- 400.05 = 0.0112-((0.053626+(3.46064814814815E-05*9*1.2))/(0.5*10)).
How to calculate Effluent BOD given Mass of Wasted Activated Sludge?
With Influent BOD (Qi), Mass of Wasted Activated Sludge (Mws), Endogenous Respiration Rate Constant (Ke), Volume of Tank (V), Mixed Liquor Suspended Solids (X'), Maximum Yield Coefficient (Y) & Sewage Discharge (Qs) we can find Effluent BOD given Mass of Wasted Activated Sludge using the formula - Effluent BOD = Influent BOD-((Mass of Wasted Activated Sludge+(Endogenous Respiration Rate Constant*Volume of Tank*Mixed Liquor Suspended Solids))/(Maximum Yield Coefficient*Sewage Discharge)).
Can the Effluent BOD given Mass of Wasted Activated Sludge be negative?
No, the Effluent BOD given Mass of Wasted Activated Sludge, measured in Density cannot be negative.
Which unit is used to measure Effluent BOD given Mass of Wasted Activated Sludge?
Effluent BOD given Mass of Wasted Activated Sludge is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Effluent BOD given Mass of Wasted Activated Sludge can be measured.
Copied!