Fx Copy
LaTeX Copy
Efficiency of Hydropower is the ratio of useful energy output generated from water flow compared to the input energy. Check FAQs
η=P9.81qflow(Hl-HWater)
η - Efficiency of Hydropower?P - Amount of Hydropower?qflow - Rate of Flow?Hl - Head loss?HWater - Head of Water?

Efficiency of Hydropower Station given Amount of Hydropower Example

With values
With units
Only example

Here is how the Efficiency of Hydropower Station given Amount of Hydropower equation looks like with Values.

Here is how the Efficiency of Hydropower Station given Amount of Hydropower equation looks like with Units.

Here is how the Efficiency of Hydropower Station given Amount of Hydropower equation looks like.

0.9085Edit=0.77Edit9.8132Edit(5Edit-2.3Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Hydraulics and Waterworks » fx Efficiency of Hydropower Station given Amount of Hydropower

Efficiency of Hydropower Station given Amount of Hydropower Solution

Follow our step by step solution on how to calculate Efficiency of Hydropower Station given Amount of Hydropower?

FIRST Step Consider the formula
η=P9.81qflow(Hl-HWater)
Next Step Substitute values of Variables
η=0.77kW9.8132m³/s(5m-2.3m)
Next Step Convert Units
η=770W9.8132m³/s(5m-2.3m)
Next Step Prepare to Evaluate
η=7709.8132(5-2.3)
Next Step Evaluate
η=0.908464529769321
LAST Step Rounding Answer
η=0.9085

Efficiency of Hydropower Station given Amount of Hydropower Formula Elements

Variables
Efficiency of Hydropower
Efficiency of Hydropower is the ratio of useful energy output generated from water flow compared to the input energy.
Symbol: η
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Amount of Hydropower
Amount of Hydropower is a form of renewable energy that uses the water stored in dams, as well as flowing in rivers to create electricity in hydropower plants.
Symbol: P
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Rate of Flow
Rate of Flow is the rate at which a liquid or other substance flows through a particular channel, pipe, etc.
Symbol: qflow
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Head loss
Head loss refers to the total pressure losses sustained by the fluid as it flows from the suction point to the discharge point.
Symbol: Hl
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Head of Water
Head of Water is defined as the height of water columns.
Symbol: HWater
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other Formulas to find Efficiency of Hydropower

​Go Efficiency of Hydropower Station given Energy through Hydraulic Turbines
η=ETurbines9.81qflow(HWater-hlocation)Tw

Other formulas in Assessment of Available Power category

​Go Amount of Hydropower
P=γfqflow(Hl-HWater)η1000
​Go Head given Amount of Hydropower
HWater=(P9.81qflowη)+hlocation
​Go Head Loss given Amount of Hydropower
hlocation=((P9.81qflowη)-HWater)
​Go Energy through Hydraulic Turbines
ETurbines=(9.81qflow(HWater-hlocation)ηTw)

How to Evaluate Efficiency of Hydropower Station given Amount of Hydropower?

Efficiency of Hydropower Station given Amount of Hydropower evaluator uses Efficiency of Hydropower = Amount of Hydropower/(9.81*Rate of Flow*(Head loss-Head of Water)) to evaluate the Efficiency of Hydropower, The Efficiency of Hydropower Station given Amount of Hydropower is defined as a fundamental reduction in amount of wasted resources that are used to produce given number of goods or services (output). Efficiency of Hydropower is denoted by η symbol.

How to evaluate Efficiency of Hydropower Station given Amount of Hydropower using this online evaluator? To use this online evaluator for Efficiency of Hydropower Station given Amount of Hydropower, enter Amount of Hydropower (P), Rate of Flow (qflow), Head loss (Hl) & Head of Water (HWater) and hit the calculate button.

FAQs on Efficiency of Hydropower Station given Amount of Hydropower

What is the formula to find Efficiency of Hydropower Station given Amount of Hydropower?
The formula of Efficiency of Hydropower Station given Amount of Hydropower is expressed as Efficiency of Hydropower = Amount of Hydropower/(9.81*Rate of Flow*(Head loss-Head of Water)). Here is an example- 8.176181 = 770/(9.81*32*(5-2.3)).
How to calculate Efficiency of Hydropower Station given Amount of Hydropower?
With Amount of Hydropower (P), Rate of Flow (qflow), Head loss (Hl) & Head of Water (HWater) we can find Efficiency of Hydropower Station given Amount of Hydropower using the formula - Efficiency of Hydropower = Amount of Hydropower/(9.81*Rate of Flow*(Head loss-Head of Water)).
What are the other ways to Calculate Efficiency of Hydropower?
Here are the different ways to Calculate Efficiency of Hydropower-
  • Efficiency of Hydropower=Energy through Hydraulic Turbines/(9.81*Rate of Flow*(Head of Water-Head Loss due to Friction)*Time Period of Progressive Wave)OpenImg
Copied!