Fx Copy
LaTeX Copy
The Efficiency of Energy Transfer describes the efficiency of energy transfer between two light-sensitive molecules (chromophores). Check FAQs
E=1-(ζDAζD)
E - Efficiency of Energy Transfer?ζDA - Donor Lifetime with FRET?ζD - Donor Lifetime?

Efficiency of Energy Transfer using Donor Lifetime Example

With values
With units
Only example

Here is how the Efficiency of Energy Transfer using Donor Lifetime equation looks like with Values.

Here is how the Efficiency of Energy Transfer using Donor Lifetime equation looks like with Units.

Here is how the Efficiency of Energy Transfer using Donor Lifetime equation looks like.

0.6Edit=1-(0.004Edit0.01Edit)
You are here -
HomeIcon Home » Category Chemistry » Category Physical Chemistry » Category Physical spectroscopy » fx Efficiency of Energy Transfer using Donor Lifetime

Efficiency of Energy Transfer using Donor Lifetime Solution

Follow our step by step solution on how to calculate Efficiency of Energy Transfer using Donor Lifetime?

FIRST Step Consider the formula
E=1-(ζDAζD)
Next Step Substitute values of Variables
E=1-(0.0040.01)
Next Step Prepare to Evaluate
E=1-(0.0040.01)
LAST Step Evaluate
E=0.6

Efficiency of Energy Transfer using Donor Lifetime Formula Elements

Variables
Efficiency of Energy Transfer
The Efficiency of Energy Transfer describes the efficiency of energy transfer between two light-sensitive molecules (chromophores).
Symbol: E
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Donor Lifetime with FRET
The Donor Lifetime with FRET is the donor fluorescence lifetimes in the presence of an acceptor.
Symbol: ζDA
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Donor Lifetime
The Donor Lifetime is the donor's fluorescence lifetime in the absence of the acceptor.
Symbol: ζD
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Efficiency of Energy Transfer

​Go Efficiency of Energy Transfer using Distances
E=11+(rR0)6
​Go Efficiency of Energy Transfer using Rate of Energy Transfer
E=KTKT+Knr+Kr
​Go Efficiency of Energy Transfer using Rate of Energy Transfer and Donor Lifetime
E=KT1ζDA
​Go Efficiency of Energy Transfer using Fluorescence Intensity of Donor
E=1-(FDAFD)

Other formulas in Förster resonance energy transfer category

​Go Forster Critical Distance
R0=0.0211((η)-4(Φd)(κ2)(J))16
​Go Donor Lifetime using Rates of Transitions
ζD=1Kr+Knr
​Go Donor Lifetime with FRET using Rate of Energy and Transitions
ζDA=1KT+Kr+Knr
​Go Rate of Energy Transfer using Distances and Donor Lifetime
KT=(1ζD)(R0r)6

How to Evaluate Efficiency of Energy Transfer using Donor Lifetime?

Efficiency of Energy Transfer using Donor Lifetime evaluator uses Efficiency of Energy Transfer = 1-(Donor Lifetime with FRET/Donor Lifetime) to evaluate the Efficiency of Energy Transfer, The Efficiency of Energy Transfer using Donor Lifetime formula is defined as the ratio of diffrence of donor lifetime without and with FRET to donor lifetime without FRET. Efficiency of Energy Transfer is denoted by E symbol.

How to evaluate Efficiency of Energy Transfer using Donor Lifetime using this online evaluator? To use this online evaluator for Efficiency of Energy Transfer using Donor Lifetime, enter Donor Lifetime with FRET DA) & Donor Lifetime D) and hit the calculate button.

FAQs on Efficiency of Energy Transfer using Donor Lifetime

What is the formula to find Efficiency of Energy Transfer using Donor Lifetime?
The formula of Efficiency of Energy Transfer using Donor Lifetime is expressed as Efficiency of Energy Transfer = 1-(Donor Lifetime with FRET/Donor Lifetime). Here is an example- -39 = 1-(0.004/0.01).
How to calculate Efficiency of Energy Transfer using Donor Lifetime?
With Donor Lifetime with FRET DA) & Donor Lifetime D) we can find Efficiency of Energy Transfer using Donor Lifetime using the formula - Efficiency of Energy Transfer = 1-(Donor Lifetime with FRET/Donor Lifetime).
What are the other ways to Calculate Efficiency of Energy Transfer?
Here are the different ways to Calculate Efficiency of Energy Transfer-
  • Efficiency of Energy Transfer=1/(1+(Donor to Acceptor Distance/Forster Critical Distance)^6)OpenImg
  • Efficiency of Energy Transfer=Rate of Energy Transfer/(Rate of Energy Transfer+Rate of Non radiative Transitions+Rate of Radiative Transitions)OpenImg
  • Efficiency of Energy Transfer=Rate of Energy Transfer/(1/Donor Lifetime with FRET)OpenImg
Copied!