Effectiveness of HE when Cold Fluid is Min Fluid depends on Mass flow rate and specific heat, is minimum for cold fluid. HE= Heat Exchanger, Min= Minimum. Check FAQs
εc=(modu̲s(Tci-Tco)Thi-Tco)
εc - Effectiveness of HE when Cold Fluid is Min Fluid?Tci - Inlet Temperature of Cold Fluid?Tco - Outlet Temperature of Cold Fluid?Thi - Inlet Temperature of Hot Fluid?

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Example

With values
With units
Only example

Here is how the Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid equation looks like with Values.

Here is how the Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid equation looks like with Units.

Here is how the Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid equation looks like.

0.5Edit=(modu̲s(283Edit-303Edit)343Edit-303Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Heat Transfer » fx Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Solution

Follow our step by step solution on how to calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?

FIRST Step Consider the formula
εc=(modu̲s(Tci-Tco)Thi-Tco)
Next Step Substitute values of Variables
εc=(modu̲s(283K-303K)343K-303K)
Next Step Prepare to Evaluate
εc=(modu̲s(283-303)343-303)
LAST Step Evaluate
εc=0.5

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Formula Elements

Variables
Functions
Effectiveness of HE when Cold Fluid is Min Fluid
Effectiveness of HE when Cold Fluid is Min Fluid depends on Mass flow rate and specific heat, is minimum for cold fluid. HE= Heat Exchanger, Min= Minimum.
Symbol: εc
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Inlet Temperature of Cold Fluid
Inlet Temperature of Cold Fluid is the temperature at which the cold fluid enters the heat exchanger.
Symbol: Tci
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Outlet Temperature of Cold Fluid
Outlet Temperature of Cold Fluid is the temperature at which the cold fluid exits the heat exchanger.
Symbol: Tco
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
Inlet Temperature of Hot Fluid
Inlet Temperature of Hot Fluid is the temperature at which the hot fluid enters the heat exchanger.
Symbol: Thi
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.
modulus
Modulus of a number is the remainder when that number is divided by another number.
Syntax: modulus

Other Formulas to find Effectiveness of HE when Cold Fluid is Min Fluid

​Go Effectiveness of Parallel-Flow Heat Exchanger if Cold Fluid is Minimum Fluid
εc=Tco-TciThi-Tci

Other formulas in Effectiveness of Heat Exchanger category

​Go Capacity Rate
C=c
​Go Fouling Factor
Rf=(1Ud)-(1U)
​Go Heat Transfer in Heat Exchanger given Cold Fluid Properties
Q=modu̲s(mccc(Tci-Tco))
​Go Heat Transfer in Heat Exchanger given Hot Fluid Properties
Q=mhch(Thi-Tho)

How to Evaluate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid evaluator uses Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)) to evaluate the Effectiveness of HE when Cold Fluid is Min Fluid, The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 or using modulus is a necessity because effectiveness cannot be negative. Effectiveness of HE when Cold Fluid is Min Fluid is denoted by εc symbol.

How to evaluate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid using this online evaluator? To use this online evaluator for Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid, enter Inlet Temperature of Cold Fluid (Tci), Outlet Temperature of Cold Fluid (Tco) & Inlet Temperature of Hot Fluid (Thi) and hit the calculate button.

FAQs on Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid

What is the formula to find Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?
The formula of Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid is expressed as Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)). Here is an example- 0.5 = (modulus((283-303))/(343-303)).
How to calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?
With Inlet Temperature of Cold Fluid (Tci), Outlet Temperature of Cold Fluid (Tco) & Inlet Temperature of Hot Fluid (Thi) we can find Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid using the formula - Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)). This formula also uses Modulus (modulus) function(s).
What are the other ways to Calculate Effectiveness of HE when Cold Fluid is Min Fluid?
Here are the different ways to Calculate Effectiveness of HE when Cold Fluid is Min Fluid-
  • Effectiveness of HE when Cold Fluid is Min Fluid=(Outlet Temperature of Cold Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)OpenImg