Effective Area of Electrode in Schering Bridge Formula

Fx Copy
LaTeX Copy
Electrode Effective Area is the area of the electrode material that is accessible to the electrolyte that is used for charge transfer and/or storage. Check FAQs
A=Csdεr[Permitivity-vacuum]
A - Electrode Effective Area?Cs - Specimen Capacitance?d - Spacing between Electrodes?εr - Relative Permittivity?[Permitivity-vacuum] - Permittivity of vacuum?

Effective Area of Electrode in Schering Bridge Example

With values
With units
Only example

Here is how the Effective Area of Electrode in Schering Bridge equation looks like with Values.

Here is how the Effective Area of Electrode in Schering Bridge equation looks like with Units.

Here is how the Effective Area of Electrode in Schering Bridge equation looks like.

1.4536Edit=6.4Edit0.4Edit199Edit8.9E-12
You are here -
HomeIcon Home » Category Engineering » Category Electronics and Instrumentation » Category Measuring Instrument Circuits » fx Effective Area of Electrode in Schering Bridge

Effective Area of Electrode in Schering Bridge Solution

Follow our step by step solution on how to calculate Effective Area of Electrode in Schering Bridge?

FIRST Step Consider the formula
A=Csdεr[Permitivity-vacuum]
Next Step Substitute values of Variables
A=6.4μF0.4mm199[Permitivity-vacuum]
Next Step Substitute values of Constants
A=6.4μF0.4mm1998.9E-12F/m
Next Step Convert Units
A=6.4E-6F0.0004m1998.9E-12F/m
Next Step Prepare to Evaluate
A=6.4E-60.00041998.9E-12
Next Step Evaluate
A=1.45359566192545
LAST Step Rounding Answer
A=1.4536

Effective Area of Electrode in Schering Bridge Formula Elements

Variables
Constants
Electrode Effective Area
Electrode Effective Area is the area of the electrode material that is accessible to the electrolyte that is used for charge transfer and/or storage.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Specimen Capacitance
Specimen Capacitance is defined as the capacitance of the given specimen or of the given electronic component.
Symbol: Cs
Measurement: CapacitanceUnit: μF
Note: Value should be greater than 0.
Spacing between Electrodes
Spacing between Electrodes is the distance between two electrodes forming a parallel plate capacitor.
Symbol: d
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Relative Permittivity
Relative Permittivity is a measure of how much electric energy a material can store compared to a vacuum. It quantifies the ability of a material to allow the formation of an electric field within it.
Symbol: εr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Permittivity of vacuum
Permittivity of vacuum is a fundamental physical constant that describes the ability of a vacuum to permit the transmission of electric field lines.
Symbol: [Permitivity-vacuum]
Value: 8.85E-12 F/m

Other formulas in Schering Bridge category

​Go Unknown Resistance in Schering Bridge
r1(sb)=(C4(sb)C2(sb))R3(sb)
​Go Unknown Capacitance in Schering Bridge
C1(sb)=(R4(sb)R3(sb))C2(sb)
​Go Dissipation Factor in Schering Bridge
D1(sb)=ωC4(sb)R4(sb)
​Go Relative Permittivity
εr=CsdA[Permitivity-vacuum]

How to Evaluate Effective Area of Electrode in Schering Bridge?

Effective Area of Electrode in Schering Bridge evaluator uses Electrode Effective Area = (Specimen Capacitance*Spacing between Electrodes)/(Relative Permittivity*[Permitivity-vacuum]) to evaluate the Electrode Effective Area, The Effective Area of Electrode in Schering Bridge formula is defined as the portion of the electrode surface area that actively participates in the capacitance formation. This area directly affects the capacitance value in the relationship between the electrodes and the dielectric material placed between them. Electrode Effective Area is denoted by A symbol.

How to evaluate Effective Area of Electrode in Schering Bridge using this online evaluator? To use this online evaluator for Effective Area of Electrode in Schering Bridge, enter Specimen Capacitance (Cs), Spacing between Electrodes (d) & Relative Permittivity r) and hit the calculate button.

FAQs on Effective Area of Electrode in Schering Bridge

What is the formula to find Effective Area of Electrode in Schering Bridge?
The formula of Effective Area of Electrode in Schering Bridge is expressed as Electrode Effective Area = (Specimen Capacitance*Spacing between Electrodes)/(Relative Permittivity*[Permitivity-vacuum]). Here is an example- 1.453596 = (6.4E-06*0.0004)/(199*[Permitivity-vacuum]).
How to calculate Effective Area of Electrode in Schering Bridge?
With Specimen Capacitance (Cs), Spacing between Electrodes (d) & Relative Permittivity r) we can find Effective Area of Electrode in Schering Bridge using the formula - Electrode Effective Area = (Specimen Capacitance*Spacing between Electrodes)/(Relative Permittivity*[Permitivity-vacuum]). This formula also uses Permittivity of vacuum constant(s).
Can the Effective Area of Electrode in Schering Bridge be negative?
No, the Effective Area of Electrode in Schering Bridge, measured in Area cannot be negative.
Which unit is used to measure Effective Area of Electrode in Schering Bridge?
Effective Area of Electrode in Schering Bridge is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Effective Area of Electrode in Schering Bridge can be measured.