Duration of Rainfall Excess given Total Runoff Depth Formula

Fx Copy
LaTeX Copy
Duration of Rainfall Excess is the total time in which the rainfall intensity the greater than the average rate of infiltration (in hours). Check FAQs
te=P-Rdφ
te - Duration of Rainfall Excess?P - Total Storm Precipitation?Rd - Total Direct Runoff?φ - Φ-Index?

Duration of Rainfall Excess given Total Runoff Depth Example

With values
With units
Only example

Here is how the Duration of Rainfall Excess given Total Runoff Depth equation looks like with Values.

Here is how the Duration of Rainfall Excess given Total Runoff Depth equation looks like with Units.

Here is how the Duration of Rainfall Excess given Total Runoff Depth equation looks like.

4.3011Edit=118Edit-117.88Edit0.0279Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Duration of Rainfall Excess given Total Runoff Depth

Duration of Rainfall Excess given Total Runoff Depth Solution

Follow our step by step solution on how to calculate Duration of Rainfall Excess given Total Runoff Depth?

FIRST Step Consider the formula
te=P-Rdφ
Next Step Substitute values of Variables
te=118cm-117.88cm0.0279
Next Step Prepare to Evaluate
te=118-117.880.0279
Next Step Evaluate
te=15483.8709677425s
Next Step Convert to Output's Unit
te=4.30107526881737h
LAST Step Rounding Answer
te=4.3011h

Duration of Rainfall Excess given Total Runoff Depth Formula Elements

Variables
Duration of Rainfall Excess
Duration of Rainfall Excess is the total time in which the rainfall intensity the greater than the average rate of infiltration (in hours).
Symbol: te
Measurement: TimeUnit: h
Note: Value should be greater than 0.
Total Storm Precipitation
Total Storm Precipitation is the annual precipitation of the current year.
Symbol: P
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Total Direct Runoff
Total Direct Runoff is the runoff entering stream channels promptly after rainfall or snowmelt.
Symbol: Rd
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Φ-Index
Φ-Index of a catchment is the constant infiltration capacity that would yield the actual total runoff for a given rainfall amount.
Symbol: φ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Φ Index category

​Go Duration of Rainfall from Rainfall Hyetograph
D=NΔt
​Go Time Interval of Rainfall Hyetograph
Δt=DN
​Go Pulses of Time Interval from Rainfall Hyetograph
N=DΔt
​Go Total Direct Runoff Depth
Rd=P-(φte)

How to Evaluate Duration of Rainfall Excess given Total Runoff Depth?

Duration of Rainfall Excess given Total Runoff Depth evaluator uses Duration of Rainfall Excess = (Total Storm Precipitation-Total Direct Runoff)/Φ-Index to evaluate the Duration of Rainfall Excess, The Duration of Rainfall Excess given Total Runoff Depth formula is defined as a process controlled at the surface of the soil. This occurs when rainfall reaches the soil at a rate in excess of the soil's ability to absorb, which is called infiltrability. Duration of Rainfall Excess is denoted by te symbol.

How to evaluate Duration of Rainfall Excess given Total Runoff Depth using this online evaluator? To use this online evaluator for Duration of Rainfall Excess given Total Runoff Depth, enter Total Storm Precipitation (P), Total Direct Runoff (Rd) & Φ-Index (φ) and hit the calculate button.

FAQs on Duration of Rainfall Excess given Total Runoff Depth

What is the formula to find Duration of Rainfall Excess given Total Runoff Depth?
The formula of Duration of Rainfall Excess given Total Runoff Depth is expressed as Duration of Rainfall Excess = (Total Storm Precipitation-Total Direct Runoff)/Φ-Index. Here is an example- 0.001195 = (1.18-1.1788)/0.0279.
How to calculate Duration of Rainfall Excess given Total Runoff Depth?
With Total Storm Precipitation (P), Total Direct Runoff (Rd) & Φ-Index (φ) we can find Duration of Rainfall Excess given Total Runoff Depth using the formula - Duration of Rainfall Excess = (Total Storm Precipitation-Total Direct Runoff)/Φ-Index.
Can the Duration of Rainfall Excess given Total Runoff Depth be negative?
No, the Duration of Rainfall Excess given Total Runoff Depth, measured in Time cannot be negative.
Which unit is used to measure Duration of Rainfall Excess given Total Runoff Depth?
Duration of Rainfall Excess given Total Runoff Depth is usually measured using the Hour[h] for Time. Second[h], Millisecond[h], Microsecond[h] are the few other units in which Duration of Rainfall Excess given Total Runoff Depth can be measured.
Copied!