Drying Surface Area based on Critical to Final Moisture Content for Falling Rate Period evaluator uses Drying Surface Area = (Dry Weight of Solid/Falling Rate Drying Time)*((Critical Moisture Content-Equilibrium Moisture Content)/Rate of Constant Drying Period)*(ln((Critical Moisture Content-Equilibrium Moisture Content)/(Final Moisture Content for Falling Rate Period-Equilibrium Moisture Content))) to evaluate the Drying Surface Area, The Drying Surface Area based on Critical to Final Moisture Content for Falling Rate Period formula is defined as the drying surface area required for drying from critical to final moisture content in the falling rate period for the specified drying conditions. Drying Surface Area is denoted by A symbol.
How to evaluate Drying Surface Area based on Critical to Final Moisture Content for Falling Rate Period using this online evaluator? To use this online evaluator for Drying Surface Area based on Critical to Final Moisture Content for Falling Rate Period, enter Dry Weight of Solid (WS), Falling Rate Drying Time (tf), Critical Moisture Content (Xc), Equilibrium Moisture Content (XEq), Rate of Constant Drying Period (Nc) & Final Moisture Content for Falling Rate Period (Xf(Falling)) and hit the calculate button.