Dry Plate Pressure Drop in Distillation Column Design Formula

Fx Copy
LaTeX Copy
Dry Plate Head Loss is the loss in pressure due to vapor flow through the holes expressed in terms of head. Check FAQs
hd=51((UhCo)2)(ρVρL)
hd - Dry Plate Head Loss?Uh - Vapor Velocity Based on Hole Area?Co - Orifice Coefficient?ρV - Vapor Density in Distillation?ρL - Liquid Density?

Dry Plate Pressure Drop in Distillation Column Design Example

With values
With units
Only example

Here is how the Dry Plate Pressure Drop in Distillation Column Design equation looks like with Values.

Here is how the Dry Plate Pressure Drop in Distillation Column Design equation looks like with Units.

Here is how the Dry Plate Pressure Drop in Distillation Column Design equation looks like.

52.2158Edit=51((20.2585Edit0.83Edit)2)(1.71Edit995Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Dry Plate Pressure Drop in Distillation Column Design

Dry Plate Pressure Drop in Distillation Column Design Solution

Follow our step by step solution on how to calculate Dry Plate Pressure Drop in Distillation Column Design?

FIRST Step Consider the formula
hd=51((UhCo)2)(ρVρL)
Next Step Substitute values of Variables
hd=51((20.2585m/s0.83)2)(1.71kg/m³995kg/m³)
Next Step Prepare to Evaluate
hd=51((20.25850.83)2)(1.71995)
Next Step Evaluate
hd=52.21575867204m
LAST Step Rounding Answer
hd=52.2158m

Dry Plate Pressure Drop in Distillation Column Design Formula Elements

Variables
Dry Plate Head Loss
Dry Plate Head Loss is the loss in pressure due to vapor flow through the holes expressed in terms of head.
Symbol: hd
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Vapor Velocity Based on Hole Area
Vapor Velocity Based on Hole Area is defined as the actual vapor velocity on the basis of hole area available to the vapor passing through the column.
Symbol: Uh
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Orifice Coefficient
Orifice Coefficient is a constant that depends on plate thickness, hole diameter and the ratio of hole to perforated area.
Symbol: Co
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Vapor Density in Distillation
Vapor Density in Distillation is defined as the ratio of mass to the volume of vapor at particular temperature in a distillation Column.
Symbol: ρV
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.
Liquid Density
Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Symbol: ρL
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.

Other formulas in Distillation Tower Design category

​Go Clearance Area under Downcomer given Weir Length and Apron Height
Aap=haplw
​Go Active Area given Gas Volumetric Flow and Flow Velocity
Aa=Gvfduf
​Go Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
Dc=(4VWπWmax)12
​Go Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
Dc=4VWπρVUv

How to Evaluate Dry Plate Pressure Drop in Distillation Column Design?

Dry Plate Pressure Drop in Distillation Column Design evaluator uses Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density) to evaluate the Dry Plate Head Loss, The Dry Plate Pressure Drop in Distillation Column Design formula is defined as the loss in Pressure due to flow of Vapor through the hole (orifice) of tray in a column. Dry Plate Head Loss is denoted by hd symbol.

How to evaluate Dry Plate Pressure Drop in Distillation Column Design using this online evaluator? To use this online evaluator for Dry Plate Pressure Drop in Distillation Column Design, enter Vapor Velocity Based on Hole Area (Uh), Orifice Coefficient (Co), Vapor Density in Distillation V) & Liquid Density L) and hit the calculate button.

FAQs on Dry Plate Pressure Drop in Distillation Column Design

What is the formula to find Dry Plate Pressure Drop in Distillation Column Design?
The formula of Dry Plate Pressure Drop in Distillation Column Design is expressed as Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density). Here is an example- 52.21576 = 51*((20.2585/0.83)^2)*(1.71/995).
How to calculate Dry Plate Pressure Drop in Distillation Column Design?
With Vapor Velocity Based on Hole Area (Uh), Orifice Coefficient (Co), Vapor Density in Distillation V) & Liquid Density L) we can find Dry Plate Pressure Drop in Distillation Column Design using the formula - Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density).
Can the Dry Plate Pressure Drop in Distillation Column Design be negative?
No, the Dry Plate Pressure Drop in Distillation Column Design, measured in Length cannot be negative.
Which unit is used to measure Dry Plate Pressure Drop in Distillation Column Design?
Dry Plate Pressure Drop in Distillation Column Design is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Dry Plate Pressure Drop in Distillation Column Design can be measured.
Copied!