Fx Copy
LaTeX Copy
Drawdown in Well 2 refers to the reduction in water level caused by pumping in a well. Check FAQs
s2=s1-(Qwlog((r2r1),10)2.72T)
s2 - Drawdown in Well 2?s1 - Drawdown in Well 1?Qw - Discharge?r2 - Radial Distance at Observation Well 2?r1 - Radial Distance at Observation Well 1?T - Aquifer Constant?

Drawdown in Well 2 given Aquifer Constant Example

With values
With units
Only example

Here is how the Drawdown in Well 2 given Aquifer Constant equation looks like with Values.

Here is how the Drawdown in Well 2 given Aquifer Constant equation looks like with Units.

Here is how the Drawdown in Well 2 given Aquifer Constant equation looks like.

2.136Edit=2.15Edit-(0.911Editlog((10Edit1.07Edit),10)2.7224.67Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Drawdown in Well 2 given Aquifer Constant

Drawdown in Well 2 given Aquifer Constant Solution

Follow our step by step solution on how to calculate Drawdown in Well 2 given Aquifer Constant?

FIRST Step Consider the formula
s2=s1-(Qwlog((r2r1),10)2.72T)
Next Step Substitute values of Variables
s2=2.15m-(0.911m³/slog((10m1.07m),10)2.7224.67)
Next Step Prepare to Evaluate
s2=2.15-(0.911log((101.07),10)2.7224.67)
Next Step Evaluate
s2=2.13601273581011m
LAST Step Rounding Answer
s2=2.136m

Drawdown in Well 2 given Aquifer Constant Formula Elements

Variables
Functions
Drawdown in Well 2
Drawdown in Well 2 refers to the reduction in water level caused by pumping in a well.
Symbol: s2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Drawdown in Well 1
Drawdown in Well 1 refers to the reduction in water level caused by pumping in a well.
Symbol: s1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
Discharge refers to the volume of water that flows through the aquifer over a given period.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Radial Distance at Observation Well 2
Radial distance at Observation Well 2 refers to the horizontal distance from the center of a pumping well to the observation well, where groundwater levels are monitored.
Symbol: r2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radial Distance at Observation Well 1
Radial distance at Observation Well 1 refers to the horizontal distance from the center of a pumping well to the observation well, where groundwater levels are monitored.
Symbol: r1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Aquifer Constant
Aquifer Constant refers to the product of the hydraulic conductivity (K) and the thickness (b) of an aquifer and also known as coefficient of transmissibility.
Symbol: T
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Drawdown in Well 2

​Go Drawdown in Well 2 given Thickness of Aquifer from Impermeable Layer
s2=H-h2
​Go Drawdown in Well 2 given Aquifer Constant and Discharge
s2=s1-(Qw2.72T)

Other formulas in Discharge And Drawdown in Well category

​Go Drawdown in Well 1 given Thickness of Aquifer from Impermeable Layer
s1=H-h1
​Go Drawdown in Well 1 given Aquifer Constant
s1=s2+(Qwlog((r2r1),10)2.72T)
​Go Discharge given Aquifer Constant
Qw=T12.72(s1-s2)
​Go Drawdown in Well 1 given Aquifer Constant and Discharge
s1=s2+(Qw2.72T)

How to Evaluate Drawdown in Well 2 given Aquifer Constant?

Drawdown in Well 2 given Aquifer Constant evaluator uses Drawdown in Well 2 = Drawdown in Well 1-((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Aquifer Constant)) to evaluate the Drawdown in Well 2, Drawdown in Well 2 given Aquifer Constant formula is defined as a measure of the decrease in water level in a well due to pumping from a nearby well in a confined aquifer system, taking into account the aquifer's properties and the distance between the wells. Drawdown in Well 2 is denoted by s2 symbol.

How to evaluate Drawdown in Well 2 given Aquifer Constant using this online evaluator? To use this online evaluator for Drawdown in Well 2 given Aquifer Constant, enter Drawdown in Well 1 (s1), Discharge (Qw), Radial Distance at Observation Well 2 (r2), Radial Distance at Observation Well 1 (r1) & Aquifer Constant (T) and hit the calculate button.

FAQs on Drawdown in Well 2 given Aquifer Constant

What is the formula to find Drawdown in Well 2 given Aquifer Constant?
The formula of Drawdown in Well 2 given Aquifer Constant is expressed as Drawdown in Well 2 = Drawdown in Well 1-((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Aquifer Constant)). Here is an example- 2.136013 = 2.15-((0.911*log((10/1.07),10))/(2.72*24.67)).
How to calculate Drawdown in Well 2 given Aquifer Constant?
With Drawdown in Well 1 (s1), Discharge (Qw), Radial Distance at Observation Well 2 (r2), Radial Distance at Observation Well 1 (r1) & Aquifer Constant (T) we can find Drawdown in Well 2 given Aquifer Constant using the formula - Drawdown in Well 2 = Drawdown in Well 1-((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Aquifer Constant)). This formula also uses Logarithmic Inverse (log) function(s).
What are the other ways to Calculate Drawdown in Well 2?
Here are the different ways to Calculate Drawdown in Well 2-
  • Drawdown in Well 2=Thickness of Aquifer-Depth of Water in Well 2OpenImg
  • Drawdown in Well 2=Drawdown in Well 1-((Discharge)/(2.72*Aquifer Constant))OpenImg
Can the Drawdown in Well 2 given Aquifer Constant be negative?
No, the Drawdown in Well 2 given Aquifer Constant, measured in Length cannot be negative.
Which unit is used to measure Drawdown in Well 2 given Aquifer Constant?
Drawdown in Well 2 given Aquifer Constant is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Drawdown in Well 2 given Aquifer Constant can be measured.
Copied!