Fx Copy
LaTeX Copy
Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test. Check FAQs
Stw=Q2.72KWHbwlog((Rwr),10)
Stw - Total Drawdown in Well?Q - Discharge?KWH - Coefficient of Permeability in Well Hydraulics?bw - Aquifer Thickness?Rw - Radius of Influence?r - Radius of Well?

Drawdown at Well given Confined Aquifer Discharge with Base 10 Example

With values
With units
Only example

Here is how the Drawdown at Well given Confined Aquifer Discharge with Base 10 equation looks like with Values.

Here is how the Drawdown at Well given Confined Aquifer Discharge with Base 10 equation looks like with Units.

Here is how the Drawdown at Well given Confined Aquifer Discharge with Base 10 equation looks like.

4.4151Edit=1.01Edit2.7210Edit14.15Editlog((8.6Edit7.5Edit),10)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Drawdown at Well given Confined Aquifer Discharge with Base 10

Drawdown at Well given Confined Aquifer Discharge with Base 10 Solution

Follow our step by step solution on how to calculate Drawdown at Well given Confined Aquifer Discharge with Base 10?

FIRST Step Consider the formula
Stw=Q2.72KWHbwlog((Rwr),10)
Next Step Substitute values of Variables
Stw=1.01m³/s2.7210cm/s14.15mlog((8.6m7.5m),10)
Next Step Convert Units
Stw=1.01m³/s2.720.1m/s14.15mlog((8.6m7.5m),10)
Next Step Prepare to Evaluate
Stw=1.012.720.114.15log((8.67.5),10)
Next Step Evaluate
Stw=4.41507185818901m
LAST Step Rounding Answer
Stw=4.4151m

Drawdown at Well given Confined Aquifer Discharge with Base 10 Formula Elements

Variables
Functions
Total Drawdown in Well
Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Symbol: Stw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
Discharge is the flow rate of water that is extracted from or injected into a well.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Coefficient of Permeability in Well Hydraulics
Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Symbol: KWH
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Aquifer Thickness
Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Symbol: bw
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Radius of Influence
Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Symbol: Rw
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radius of Well
Radius of Well is defined as the distance from center of well to its outer boundary.
Symbol: r
Measurement: LengthUnit: m
Note: Value should be greater than 0.
log
Logarithmic function is an inverse function to exponentiation.
Syntax: log(Base, Number)

Other Formulas to find Total Drawdown in Well

​Go Drawdown at Well given Confined Aquifer Discharge
Stw=Q2πKWHbplog((Rwr),e)
​Go Drawdown at Well given Coefficient of Transmissibility with Base 10
Stw=Q2.72Tenvilog((Rwr),10)

Other formulas in Drawdown at well category

​Go Drawdown at Well given Coefficient of Transmissibility
st=Q2πTenvilog((Rwr),e)

How to Evaluate Drawdown at Well given Confined Aquifer Discharge with Base 10?

Drawdown at Well given Confined Aquifer Discharge with Base 10 evaluator uses Total Drawdown in Well = Discharge/((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness)/(log((Radius of Influence/Radius of Well),10))) to evaluate the Total Drawdown in Well, The Drawdown at Well given Confined Aquifer Discharge with Base 10 formula is defined as the value of drawdown at well when we have prior information of confined aquifer discharge. Total Drawdown in Well is denoted by Stw symbol.

How to evaluate Drawdown at Well given Confined Aquifer Discharge with Base 10 using this online evaluator? To use this online evaluator for Drawdown at Well given Confined Aquifer Discharge with Base 10, enter Discharge (Q), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button.

FAQs on Drawdown at Well given Confined Aquifer Discharge with Base 10

What is the formula to find Drawdown at Well given Confined Aquifer Discharge with Base 10?
The formula of Drawdown at Well given Confined Aquifer Discharge with Base 10 is expressed as Total Drawdown in Well = Discharge/((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness)/(log((Radius of Influence/Radius of Well),10))). Here is an example- 4.164884 = 1.01/((2.72*0.1*14.15)/(log((8.6/7.5),10))).
How to calculate Drawdown at Well given Confined Aquifer Discharge with Base 10?
With Discharge (Q), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Radius of Influence (Rw) & Radius of Well (r) we can find Drawdown at Well given Confined Aquifer Discharge with Base 10 using the formula - Total Drawdown in Well = Discharge/((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness)/(log((Radius of Influence/Radius of Well),10))). This formula also uses Logarithmic Inverse Function function(s).
What are the other ways to Calculate Total Drawdown in Well?
Here are the different ways to Calculate Total Drawdown in Well-
  • Total Drawdown in Well=Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping)/(log((Radius of Influence/Radius of Well),e)))OpenImg
  • Total Drawdown in Well=Discharge/((2.72*Coefficient of Transmissibility)/(log((Radius of Influence/Radius of Well),10)))OpenImg
Can the Drawdown at Well given Confined Aquifer Discharge with Base 10 be negative?
No, the Drawdown at Well given Confined Aquifer Discharge with Base 10, measured in Length cannot be negative.
Which unit is used to measure Drawdown at Well given Confined Aquifer Discharge with Base 10?
Drawdown at Well given Confined Aquifer Discharge with Base 10 is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Drawdown at Well given Confined Aquifer Discharge with Base 10 can be measured.
Copied!