Drawdown at Time Interval t2 is the decrease in hydraulic head (or groundwater level) in a well or aquifer over a specific time period. Check FAQs
s2=((Q4πT)ln(t2t1))+s1
s2 - Drawdown at Time Interval t2?Q - Discharge?T - Transmissivity?t2 - Time of Drawdown (t2)?t1 - Time of Drawdown (t1)?s1 - Drawdown at Time Interval t1?π - Archimedes' constant?

Drawdown at Time Interval 't2' Example

With values
With units
Only example

Here is how the Drawdown at Time Interval 't2' equation looks like with Values.

Here is how the Drawdown at Time Interval 't2' equation looks like with Units.

Here is how the Drawdown at Time Interval 't2' equation looks like.

14.9461Edit=((3Edit43.141611Edit)ln(10Edit120Edit))+15Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Drawdown at Time Interval 't2'

Drawdown at Time Interval 't2' Solution

Follow our step by step solution on how to calculate Drawdown at Time Interval 't2'?

FIRST Step Consider the formula
s2=((Q4πT)ln(t2t1))+s1
Next Step Substitute values of Variables
s2=((3m³/s4π11m²/s)ln(10s120s))+15m
Next Step Substitute values of Constants
s2=((3m³/s43.141611m²/s)ln(10s120s))+15m
Next Step Prepare to Evaluate
s2=((343.141611)ln(10120))+15
Next Step Evaluate
s2=14.9460702032133m
LAST Step Rounding Answer
s2=14.9461m

Drawdown at Time Interval 't2' Formula Elements

Variables
Constants
Functions
Drawdown at Time Interval t2
Drawdown at Time Interval t2 is the decrease in hydraulic head (or groundwater level) in a well or aquifer over a specific time period.
Symbol: s2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge
Discharge is the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Transmissivity
Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Symbol: T
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value can be positive or negative.
Time of Drawdown (t2)
Time of Drawdown (t2) is the total period for the difference between the pumping water level and the static (non-pumping) water level.
Symbol: t2
Measurement: TimeUnit: s
Note: Value can be positive or negative.
Time of Drawdown (t1)
Time of Drawdown (t1) is the total period for the difference between the pumping water level and the static (non-pumping) water level.
Symbol: t1
Measurement: TimeUnit: s
Note: Value can be positive or negative.
Drawdown at Time Interval t1
Drawdown at Time Interval t1 is the decrease in the water level or hydraulic head in a well or an aquifer over a specified period after the start of pumping.
Symbol: s1
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other formulas in Unsteady Flow in a Confined Aquifer category

​Go Drawdown
st=(Q4πT)ln(2.2Ttr2S)
​Go Drawdown at Time Interval 't1'
s1=s2-((Q4πT)ln(t2t1))
​Go Equation for Storage Coefficient
S=2.25Tt0r2
​Go Transmissivity about given Storage Coefficient
T=Sr22.25t0

How to Evaluate Drawdown at Time Interval 't2'?

Drawdown at Time Interval 't2' evaluator uses Drawdown at Time Interval t2 = ((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))+Drawdown at Time Interval t1 to evaluate the Drawdown at Time Interval t2, The Drawdown at Time Interval 't2' formula is defined as the measurement of the decline in water level in a well or piezometer at a specific time, typically denoted as 't2'. Drawdown at Time Interval t2 is denoted by s2 symbol.

How to evaluate Drawdown at Time Interval 't2' using this online evaluator? To use this online evaluator for Drawdown at Time Interval 't2', enter Discharge (Q), Transmissivity (T), Time of Drawdown (t2) (t2), Time of Drawdown (t1) (t1) & Drawdown at Time Interval t1 (s1) and hit the calculate button.

FAQs on Drawdown at Time Interval 't2'

What is the formula to find Drawdown at Time Interval 't2'?
The formula of Drawdown at Time Interval 't2' is expressed as Drawdown at Time Interval t2 = ((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))+Drawdown at Time Interval t1. Here is an example- 14.94607 = ((3/(4*pi*11))*ln(10/120))+15.
How to calculate Drawdown at Time Interval 't2'?
With Discharge (Q), Transmissivity (T), Time of Drawdown (t2) (t2), Time of Drawdown (t1) (t1) & Drawdown at Time Interval t1 (s1) we can find Drawdown at Time Interval 't2' using the formula - Drawdown at Time Interval t2 = ((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))+Drawdown at Time Interval t1. This formula also uses Archimedes' constant and Natural Logarithm (ln) function(s).
Can the Drawdown at Time Interval 't2' be negative?
Yes, the Drawdown at Time Interval 't2', measured in Length can be negative.
Which unit is used to measure Drawdown at Time Interval 't2'?
Drawdown at Time Interval 't2' is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Drawdown at Time Interval 't2' can be measured.
Copied!