Drain Current after Voltage Scaling VLSI Formula

Fx Copy
LaTeX Copy
Drain Current after Voltage Scaling is referred to the current flowing through the drain terminal after scaling down the device by voltage scaling method. Check FAQs
ID(vs)'=SfID
ID(vs)' - Drain Current after Voltage Scaling?Sf - Scaling Factor?ID - Drain Current?

Drain Current after Voltage Scaling VLSI Example

With values
With units
Only example

Here is how the Drain Current after Voltage Scaling VLSI equation looks like with Values.

Here is how the Drain Current after Voltage Scaling VLSI equation looks like with Units.

Here is how the Drain Current after Voltage Scaling VLSI equation looks like.

1.599Edit=1.5Edit1.066Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category VLSI Fabrication » fx Drain Current after Voltage Scaling VLSI

Drain Current after Voltage Scaling VLSI Solution

Follow our step by step solution on how to calculate Drain Current after Voltage Scaling VLSI?

FIRST Step Consider the formula
ID(vs)'=SfID
Next Step Substitute values of Variables
ID(vs)'=1.51.066mA
Next Step Convert Units
ID(vs)'=1.50.0011A
Next Step Prepare to Evaluate
ID(vs)'=1.50.0011
Next Step Evaluate
ID(vs)'=0.001599A
LAST Step Convert to Output's Unit
ID(vs)'=1.599mA

Drain Current after Voltage Scaling VLSI Formula Elements

Variables
Drain Current after Voltage Scaling
Drain Current after Voltage Scaling is referred to the current flowing through the drain terminal after scaling down the device by voltage scaling method.
Symbol: ID(vs)'
Measurement: Electric CurrentUnit: mA
Note: Value can be positive or negative.
Scaling Factor
Scaling factor is defined as the ratio by which the dimensions of the transistor are changed during the design process.
Symbol: Sf
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Drain Current
Drain Current is the current flowing from the source to the drain terminal under the influence of the voltage applied to the gate terminal.
Symbol: ID
Measurement: Electric CurrentUnit: mA
Note: Value should be greater than 0.

Other formulas in VLSI Material Optimization category

​Go Body Effect Coefficient
γ=modu̲s(Vt-Vt0Φs+(Vsb)-Φs)
​Go Channel Charge
Qch=Cg(Vgc-Vt)
​Go Critical Voltage
Vx=ExEch
​Go DIBL Coefficient
η=Vt0-VtVds

How to Evaluate Drain Current after Voltage Scaling VLSI?

Drain Current after Voltage Scaling VLSI evaluator uses Drain Current after Voltage Scaling = Scaling Factor*Drain Current to evaluate the Drain Current after Voltage Scaling, The Drain Current after Voltage Scaling VLSI formula is defined as the current flowing through the drain terminal after scaling down the device by voltage scaling method. Drain Current after Voltage Scaling is denoted by ID(vs)' symbol.

How to evaluate Drain Current after Voltage Scaling VLSI using this online evaluator? To use this online evaluator for Drain Current after Voltage Scaling VLSI, enter Scaling Factor (Sf) & Drain Current (ID) and hit the calculate button.

FAQs on Drain Current after Voltage Scaling VLSI

What is the formula to find Drain Current after Voltage Scaling VLSI?
The formula of Drain Current after Voltage Scaling VLSI is expressed as Drain Current after Voltage Scaling = Scaling Factor*Drain Current. Here is an example- 1599 = 1.5*0.001066.
How to calculate Drain Current after Voltage Scaling VLSI?
With Scaling Factor (Sf) & Drain Current (ID) we can find Drain Current after Voltage Scaling VLSI using the formula - Drain Current after Voltage Scaling = Scaling Factor*Drain Current.
Can the Drain Current after Voltage Scaling VLSI be negative?
Yes, the Drain Current after Voltage Scaling VLSI, measured in Electric Current can be negative.
Which unit is used to measure Drain Current after Voltage Scaling VLSI?
Drain Current after Voltage Scaling VLSI is usually measured using the Milliampere[mA] for Electric Current. Ampere[mA], Microampere[mA], Centiampere[mA] are the few other units in which Drain Current after Voltage Scaling VLSI can be measured.
Copied!