Drain Current after Full Scaling VLSI Formula

Fx Copy
LaTeX Copy
Drain Current after Full Scaling is defined as a drain current value after reduction in dimensions of MOSFET by full scaling. Check FAQs
ID'=IDSf
ID' - Drain Current after Full Scaling?ID - Drain Current?Sf - Scaling Factor?

Drain Current after Full Scaling VLSI Example

With values
With units
Only example

Here is how the Drain Current after Full Scaling VLSI equation looks like with Values.

Here is how the Drain Current after Full Scaling VLSI equation looks like with Units.

Here is how the Drain Current after Full Scaling VLSI equation looks like.

0.7107Edit=1.066Edit1.5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category VLSI Fabrication » fx Drain Current after Full Scaling VLSI

Drain Current after Full Scaling VLSI Solution

Follow our step by step solution on how to calculate Drain Current after Full Scaling VLSI?

FIRST Step Consider the formula
ID'=IDSf
Next Step Substitute values of Variables
ID'=1.066mA1.5
Next Step Convert Units
ID'=0.0011A1.5
Next Step Prepare to Evaluate
ID'=0.00111.5
Next Step Evaluate
ID'=0.000710666666666667A
Next Step Convert to Output's Unit
ID'=0.710666666666667mA
LAST Step Rounding Answer
ID'=0.7107mA

Drain Current after Full Scaling VLSI Formula Elements

Variables
Drain Current after Full Scaling
Drain Current after Full Scaling is defined as a drain current value after reduction in dimensions of MOSFET by full scaling.
Symbol: ID'
Measurement: Electric CurrentUnit: mA
Note: Value should be greater than 0.
Drain Current
Drain Current is the current flowing from the source to the drain terminal under the influence of the voltage applied to the gate terminal.
Symbol: ID
Measurement: Electric CurrentUnit: mA
Note: Value should be greater than 0.
Scaling Factor
Scaling factor is defined as the ratio by which the dimensions of the transistor are changed during the design process.
Symbol: Sf
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in VLSI Material Optimization category

​Go Body Effect Coefficient
γ=modu̲s(Vt-Vt0Φs+(Vsb)-Φs)
​Go Channel Charge
Qch=Cg(Vgc-Vt)
​Go Critical Voltage
Vx=ExEch
​Go DIBL Coefficient
η=Vt0-VtVds

How to Evaluate Drain Current after Full Scaling VLSI?

Drain Current after Full Scaling VLSI evaluator uses Drain Current after Full Scaling = Drain Current/Scaling Factor to evaluate the Drain Current after Full Scaling, The Drain Current after Full Scaling VLSI formula is defined as a drain current value after reduction in dimensions of MOSFET by full scaling. Drain Current after Full Scaling is denoted by ID' symbol.

How to evaluate Drain Current after Full Scaling VLSI using this online evaluator? To use this online evaluator for Drain Current after Full Scaling VLSI, enter Drain Current (ID) & Scaling Factor (Sf) and hit the calculate button.

FAQs on Drain Current after Full Scaling VLSI

What is the formula to find Drain Current after Full Scaling VLSI?
The formula of Drain Current after Full Scaling VLSI is expressed as Drain Current after Full Scaling = Drain Current/Scaling Factor. Here is an example- 710.6667 = 0.001066/1.5.
How to calculate Drain Current after Full Scaling VLSI?
With Drain Current (ID) & Scaling Factor (Sf) we can find Drain Current after Full Scaling VLSI using the formula - Drain Current after Full Scaling = Drain Current/Scaling Factor.
Can the Drain Current after Full Scaling VLSI be negative?
No, the Drain Current after Full Scaling VLSI, measured in Electric Current cannot be negative.
Which unit is used to measure Drain Current after Full Scaling VLSI?
Drain Current after Full Scaling VLSI is usually measured using the Milliampere[mA] for Electric Current. Ampere[mA], Microampere[mA], Centiampere[mA] are the few other units in which Drain Current after Full Scaling VLSI can be measured.
Copied!