Downcomer Liquid Load in Trays Formula

Fx Copy
LaTeX Copy
Downcomer Liquid Load refers to the velocity of clear liquid component flowing through the downcomer entrance of a tray. Check FAQs
QD=VAd
QD - Downcomer Liquid Load?V - Liquid Flow over Tray?Ad - Downcomer Area?

Downcomer Liquid Load in Trays Example

With values
With units
Only example

Here is how the Downcomer Liquid Load in Trays equation looks like with Values.

Here is how the Downcomer Liquid Load in Trays equation looks like with Units.

Here is how the Downcomer Liquid Load in Trays equation looks like.

0.5721Edit=0.0565Edit0.0987Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Downcomer Liquid Load in Trays

Downcomer Liquid Load in Trays Solution

Follow our step by step solution on how to calculate Downcomer Liquid Load in Trays?

FIRST Step Consider the formula
QD=VAd
Next Step Substitute values of Variables
QD=0.0565m³/s0.0987
Next Step Prepare to Evaluate
QD=0.05650.0987
Next Step Evaluate
QD=0.572123176661264m/s
LAST Step Rounding Answer
QD=0.5721m/s

Downcomer Liquid Load in Trays Formula Elements

Variables
Downcomer Liquid Load
Downcomer Liquid Load refers to the velocity of clear liquid component flowing through the downcomer entrance of a tray.
Symbol: QD
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Liquid Flow over Tray
Liquid Flow over Tray refers to the volumetric flowrate of liquid component in a tray tower.
Symbol: V
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Downcomer Area
Downcomer area refers to the section or passage that allows the liquid phase to flow from the higher tray or stage to the lower tray or stage.
Symbol: Ad
Measurement: AreaUnit:
Note: Value should be greater than 0.

Other formulas in Distillation Tower Design category

​Go Clearance Area under Downcomer given Weir Length and Apron Height
Aap=haplw
​Go Active Area given Gas Volumetric Flow and Flow Velocity
Aa=Gvfduf
​Go Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
Dc=(4VWπWmax)12
​Go Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
Dc=4VWπρVUv

How to Evaluate Downcomer Liquid Load in Trays?

Downcomer Liquid Load in Trays evaluator uses Downcomer Liquid Load = Liquid Flow over Tray/Downcomer Area to evaluate the Downcomer Liquid Load, The Downcomer Liquid Load in Trays formula is defined as velocity with which the clear liquid component passes through the downcomer entrance of tray. Downcomer Liquid Load is denoted by QD symbol.

How to evaluate Downcomer Liquid Load in Trays using this online evaluator? To use this online evaluator for Downcomer Liquid Load in Trays, enter Liquid Flow over Tray (V) & Downcomer Area (Ad) and hit the calculate button.

FAQs on Downcomer Liquid Load in Trays

What is the formula to find Downcomer Liquid Load in Trays?
The formula of Downcomer Liquid Load in Trays is expressed as Downcomer Liquid Load = Liquid Flow over Tray/Downcomer Area. Here is an example- 0.572123 = 0.05648/0.09872.
How to calculate Downcomer Liquid Load in Trays?
With Liquid Flow over Tray (V) & Downcomer Area (Ad) we can find Downcomer Liquid Load in Trays using the formula - Downcomer Liquid Load = Liquid Flow over Tray/Downcomer Area.
Can the Downcomer Liquid Load in Trays be negative?
No, the Downcomer Liquid Load in Trays, measured in Speed cannot be negative.
Which unit is used to measure Downcomer Liquid Load in Trays?
Downcomer Liquid Load in Trays is usually measured using the Meter per Second[m/s] for Speed. Meter per Minute[m/s], Meter per Hour[m/s], Kilometer per Hour[m/s] are the few other units in which Downcomer Liquid Load in Trays can be measured.
Copied!