Distance of Top of Pipe to below Surface of Fill given Unit Pressure Formula

Fx Copy
LaTeX Copy
The Distance between Pipe and Fill refers to the distance between the upper part of pipe to lower end of fill. Check FAQs
H=(Pt2π(hSlant)53P)13
H - Distance between Pipe and Fill?Pt - Unit Pressure?hSlant - Slant Height?P - Superimposed Load?π - Archimedes' constant?

Distance of Top of Pipe to below Surface of Fill given Unit Pressure Example

With values
With units
Only example

Here is how the Distance of Top of Pipe to below Surface of Fill given Unit Pressure equation looks like with Values.

Here is how the Distance of Top of Pipe to below Surface of Fill given Unit Pressure equation looks like with Units.

Here is how the Distance of Top of Pipe to below Surface of Fill given Unit Pressure equation looks like.

2.9413Edit=(16Edit23.1416(1.5Edit)5310Edit)13
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Distance of Top of Pipe to below Surface of Fill given Unit Pressure

Distance of Top of Pipe to below Surface of Fill given Unit Pressure Solution

Follow our step by step solution on how to calculate Distance of Top of Pipe to below Surface of Fill given Unit Pressure?

FIRST Step Consider the formula
H=(Pt2π(hSlant)53P)13
Next Step Substitute values of Variables
H=(16Pa2π(1.5m)5310N)13
Next Step Substitute values of Constants
H=(16Pa23.1416(1.5m)5310N)13
Next Step Prepare to Evaluate
H=(1623.1416(1.5)5310)13
Next Step Evaluate
H=2.94133820387017m
LAST Step Rounding Answer
H=2.9413m

Distance of Top of Pipe to below Surface of Fill given Unit Pressure Formula Elements

Variables
Constants
Distance between Pipe and Fill
The Distance between Pipe and Fill refers to the distance between the upper part of pipe to lower end of fill.
Symbol: H
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Unit Pressure
The Unit Pressure refers to a developed at any point in the fill at a depth of H below the surface.
Symbol: Pt
Measurement: PressureUnit: Pa
Note: Value should be greater than 0.
Slant Height
The Slant Height refers to the height of a cone from the vertex to the periphery (rather than the center) of the base.
Symbol: hSlant
Measurement: LengthUnit: m
Note: Value should be between 1 to 10.
Superimposed Load
Superimposed Load Thermal Expansion Coefficient is a material property that is indicative of the extent to which a material expands upon heating.
Symbol: P
Measurement: ForceUnit: N
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Pressure Due to External Loads category

​Go Load Per Unit Length for Pipes Resting on Undisturbed Ground on Cohesion Less Soil
W=Cpγ(D)2
​Go Pipe Coefficient given Load Per Unit Length for Pipes
Cp=(Wγ(D)2)
​Go Specific Weight of Fill Material given Load Per Unit Length for Pipes
γ=WCp(D)2
​Go External Diameter of Pipe given Load Per Unit Length for Pipes
D=WCpγ

How to Evaluate Distance of Top of Pipe to below Surface of Fill given Unit Pressure?

Distance of Top of Pipe to below Surface of Fill given Unit Pressure evaluator uses Distance between Pipe and Fill = ((Unit Pressure*2*pi*(Slant Height)^5)/(3*Superimposed Load))^(1/3) to evaluate the Distance between Pipe and Fill, The Distance of Top of Pipe to below Surface of Fill given Unit Pressure calculates the distance of top of pipe to below the surface of fill when we have other parameters known. Distance between Pipe and Fill is denoted by H symbol.

How to evaluate Distance of Top of Pipe to below Surface of Fill given Unit Pressure using this online evaluator? To use this online evaluator for Distance of Top of Pipe to below Surface of Fill given Unit Pressure, enter Unit Pressure (Pt), Slant Height (hSlant) & Superimposed Load (P) and hit the calculate button.

FAQs on Distance of Top of Pipe to below Surface of Fill given Unit Pressure

What is the formula to find Distance of Top of Pipe to below Surface of Fill given Unit Pressure?
The formula of Distance of Top of Pipe to below Surface of Fill given Unit Pressure is expressed as Distance between Pipe and Fill = ((Unit Pressure*2*pi*(Slant Height)^5)/(3*Superimposed Load))^(1/3). Here is an example- 2.941338 = ((16*2*pi*(1.5)^5)/(3*10))^(1/3).
How to calculate Distance of Top of Pipe to below Surface of Fill given Unit Pressure?
With Unit Pressure (Pt), Slant Height (hSlant) & Superimposed Load (P) we can find Distance of Top of Pipe to below Surface of Fill given Unit Pressure using the formula - Distance between Pipe and Fill = ((Unit Pressure*2*pi*(Slant Height)^5)/(3*Superimposed Load))^(1/3). This formula also uses Archimedes' constant .
Can the Distance of Top of Pipe to below Surface of Fill given Unit Pressure be negative?
No, the Distance of Top of Pipe to below Surface of Fill given Unit Pressure, measured in Length cannot be negative.
Which unit is used to measure Distance of Top of Pipe to below Surface of Fill given Unit Pressure?
Distance of Top of Pipe to below Surface of Fill given Unit Pressure is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Distance of Top of Pipe to below Surface of Fill given Unit Pressure can be measured.
Copied!